MAURY USCG vessel records
← All vessels

SEA HELIOS

SEA HELIOS is a 2004 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in April 2023, along with 4 deficiencies and 4 operational controls.

Records from 2016 to 2023. Most recent: inspection, 25 April 2023.

Built
2004
Last inspected
25 April 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 April 2023
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9279719
9HA3224
727783
Flag
MALTA
Maury page id
psix-727783

Documentation record

Tonnage as PSIX records it11553 - Convention (Subpart B), Net Ton
28069 - Regulatory (Subpart C or D), Gross Ton
39999 - Dead Weight, Metric Ton
48831 - Displacement, Metric Ton
11553 - Regulatory (Subpart C or D), Net Ton
28069 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

25 April 2023 PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7675113
24 April 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7674930
18 April 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7670922
23 January 2022 COC-TVE Renew
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7380599
2 December 2020 Bulk Liquid Transfer Monitor
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7106114
31 October 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7087532
15 September 2020 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7058499
21 July 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7012453
7 April 2020 PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6936020
30 March 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6933252
21 January 2019 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6609910
16 December 2018 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6598417
14 December 2018 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6597197
21 December 2017 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6327117
14 June 2017 Administrative Inspection · COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6175555
6 December 2016 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6049078

Deficiency record · 4

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 16 September 2020 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect on board tankers, unless appropriately certified for safe usage in the dust, vapours, or gases likely to be encountered. Multiple junction boxes for ballast water system controls and valve controls located in the pump room are not properly installed. Cables entering multiple enclosures are missing rubber glands. (74) SOLAS 02 II-1/45.10.4 Action Taken: 17 b,c
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2020
Resolved 17 September 2020
Resolution: Rubber glands properly installed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 16 September 2020 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. In meeting these requirements the company should ensure that inspections are held at appropriate intervals and equipment is maintained. Objective evidence: 2 of 3 grease fittings on all cargo pump gastight seals painted over, not maintained (corrected on spot); grease spring positive pressure cap cracked on 3 of 4 cargo pumps. (74)SOLAS14 IX/3.1, ISM Reg. 10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2020
Resolved 17 September 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 April 2020 Resolved
Cargo pumps, ballast pumps, & stripping pumps installed in cargo pump rooms and driven by shafts passing through the pump room bulkheads shall be fitted with temperature sensing devices for bulkheads, shaft glands, bearings, and head casings. Marine chemist was not able to certify space due to unavailability. Cite: SOLAS74(14) II-2/5.10.1 Action:40C
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 September 2020
Resolution: Recieved proper documentation to clear deficiency.
Lifesaving › Inflatable Liferafts › Painter
Issued 6 December 2016 Resolved
0620- Inflatable liferafts- Each liferaft or group of liferafts shall be stowed with a float-free arrangements of paragraph 4.1.6 of the Code so that each floats free and, if inflatable, inflates automatically when the ship sinks. Painter line was not connected to the weak link on the port side liferaft. 74 SOLAS (04 cons) III/13.4.2- 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 December 2016
Resolved 7 December 2016
Resolution: Witnessed proper connection of painter line to weak link.

Ownership record