MAURY USCG vessel records Sign in
← All vessels

CAP LEON

CAP LEON is a 2003 tank ship. The Coast Guard has recorded 20 inspections since 2004, most recently in June 2021, along with 1 deficiency and 6 operational controls.

Records from 2004 to 2021. Most recent: inspection, 15 June 2021.

Built
2003
Last inspected
15 June 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9274434 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
727962
Flag
LIBERIA
—
Maury page id
psix-727962

Inspections, by type

…with no type recorded6
Years with a record 12 calendar years (2004–2021)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it51254 - Regulatory (Subpart C or D), Net Ton
51254 - Convention (Subpart B), Net Ton
182732 - Displacement, Ton
159048 - Dead Weight, Ton
81328 - Regulatory (Subpart C or D), Gross Ton
81328 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

15 June 2021 PSC B · COC-TVE Renew
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7220532
9 June 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7220617
2 March 2020 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6914794
22 July 2018 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6479488
21 May 2018 COE-Dockside
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6420015
11 January 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Annual · COE-Dockside
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6336416
5 September 2017 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6259890
5 May 2017 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6139987
13 December 2016 ISPS II Exam · COC-TVE Renew · COE-Offshore · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6056826
8 December 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6054976
19 December 2015 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5783663
17 December 2015 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 5784153
16 December 2015 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5782682
16 July 2012 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4376551
2 September 2010 ISPS I Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3840700
13 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3533188
9 April 2009 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3448836
1 March 2006 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2592573
10 April 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2330417
1 November 2004 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2232345

Deficiency record · 1

Deck/Cargo › Inert Gas System › IGS Blower
Issued 19 December 2015 Resolved
Special consideration shall be given to the design and location of scrubber and blowers with relevant pipingand fittings in order to prevent flue gas leakage into enclosed spaces. PSCO and ships Officer's gas alarm both alarmed in the blower room. PSCO alarm was 53 PPM CO and rising as PSCO entered space.
Condition: Improper/Lack of Maintenance
Due 25 December 2015
Resolved 21 December 2015
Resolution: 21dec15 Conducted a PSC administrative Deficiency Check. Received a class report/proper documentation satisfying the requirement. replaced packing on blower tested space, no CO readings. Cleared 01 deficiencies from 00 deficiencies remain outstanding.

Ownership record