MAURY USCG vessel records Sign in
← All vessels

NORD WHALE

NORD WHALE is a 2004 freight ship. The Coast Guard has recorded 7 inspections since 2004, most recently in September 2008, along with 4 deficiencies.

Records from 2004 to 2008. Most recent: inspection, 26 September 2008.

Built
2004
Last inspected
26 September 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

728305
Flag
DENMARK
—
Maury page id
psix-728305

Inspections, by type

…with no type recorded1
Years with a record 3 calendar years (2004–2008)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it27989 - Convention (Subpart B), Gross Ton
17077 - Convention (Subpart B), Net Ton
58136 - Displacement, Ton
50354 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

26 September 2008 Deficiency Check · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3333162
10 July 2008 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3263592
1 January 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3123375
5 February 2005 Random ISPS/MTSA/PSC
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2287224
1 December 2004 ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2250508
17 November 2004 PII Safety Exam · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2242579
15 November 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2241741

Deficiency record · 4

Operations/Management › Drills/Instruction › Fire
Issued 17 November 2004 Resolved
Fire drill performance was unsatisfactory on first attempt. Crew was very unorganized and assembled directly in front of the location of the fire.
Due 17 November 2004
Resolved 17 November 2004
Resolution: The crew performed successfully during the last attempt and the item was corrected.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 17 November 2004 Resolved
Provide all necessary supplies and equipment to test smoke detectors, thermal detectors, and flame detectors as per Fire Detection Plan DWG No. 6VEO390
Action required: 705 - Other - as specified
Due 1 December 2004
Resolved 1 December 2004
Resolution: Recieved class report from NKK satisfying requirement.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 17 November 2004 Resolved
Ensure the vessel crew members who are responsible for testing the fire detection system are instructed on proper testing procedures.
Action required: 705 - Other - as specified
Due 1 December 2004
Resolved 1 December 2004
Resolution: Recieved class report from NKK satisfying requirement.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 17 November 2004 Resolved
Class to examine all fire detector heads. Heads are damaged from crew using other than proper means for testing.
Action required: 705 - Other - as specified
Due 1 December 2004
Resolved 1 December 2004
Resolution: Recieved class report from NKK satisfying requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.