BW LARA is a 2003 tank ship. The Coast Guard has recorded 25 inspections since 2004, most recently in April 2022, along with 29 deficiencies and 6 operational controls.

Records from 2004 to 2022. Most recent: inspection, 12 April 2022.

Built
2003
Last inspected
12 April 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9269257 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V2885
728461
Flag
SINGAPORE
—
Maury page id
psix-728461

Inspections, by type

…with no type recorded13
Years with a record 10 calendar years (2004–2022)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it22047 - Convention (Subpart B), Net Ton
73496 - Dead Weight, Ton
88869 - Displacement, Ton
42011 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

12 April 2022 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7429738
16 February 2022 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7394306
10 February 2022 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7394251
14 May 2017 Deficiency Check · COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6145755
12 August 2015 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5214482
9 May 2014 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4854498
28 April 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3463162
1 March 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3425851
6 November 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3358418
3 November 2008 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3356740
21 March 2007 Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2895209
20 March 2007 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2891555
19 March 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2890855
17 March 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2889846
2 October 2006 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2791697
3 May 2006 Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2635716
7 April 2006 Type not recorded
No type recorded · MARITIME SECURITY RESPONSE TEAM WEST · Activity 2619834
17 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2516420
14 July 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2426940
22 May 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2364880
24 April 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2341886
20 April 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2339382
27 February 2005 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2300304
23 November 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2246590
10 November 2004 COC-TVE Renew · ISPS II Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2235945

Deficiency record · 29

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 February 2022 Resolved
07126-Fire Safety-Means shall be provided to control leaks of flammable liquids. PSCO noticed excess fuel oil on SSDG #1 & #2 coming #7 cylinder & by fuel pumps. 74 SOLAS (14) II-2/4.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2022
Resolved 17 February 2022
Resolution: Lloyds provided documentation and proof of corrective actions that were up to USCG standards. Deficiency cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 February 2022 Resolved
09219-Working Conditions-Surfaces with temperatures of 220 C which may be impinged as a result of fuel system failure shall be properly insolated. PSCO noticed lagging missing from #3 SSDG exhaust manifold. 74 SOLAS (14) II-2/4.2.2.6.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2022
Resolved 12 April 2022
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 14 May 2017 Resolved
Engine Room Alarm system is currently provided with power from the main ships supply due to a faulty converter. Ship to provide documentation from the technician identifying the propblem and class documentation attesting an adequate repair proposal.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 14 May 2017 Resolved
Written procedure could not be provided to identify the specifc steps to properly demonstrate the required IGS system shutdowns and associated alarms.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Received Class report. Written procesdures now provided for the ships crew regarding proper procedures for the IGS system.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 14 May 2017 Resolved
IGG/IGS manual not updated to reflect the generator being decommissioned in 2014.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Class endorsed the IGS/IGG manual as approved prior to completion of USCG examination.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 14 May 2017 Resolved
Steering Gear local rudder angle indicator displays readings 10 degress error.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 May 2017 Resolved
All Portable and semi portable extinguishers had defective, missing, or broken brackets and securing arrangments.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Fire Fighting › Fire Hoses › Condition
Issued 14 May 2017 Resolved
Fire hoses in Engine Room are wasted and worn.
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 19 May 2017
Resolution: Received Class report attesting to the renewal of all fire hoses within the engine room space.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 May 2017 Resolved
Emergency Lighting fixture above the emergency generator room panel is inoperable.
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 19 May 2017
Resolution: Received Class report attesting to the proper operation of the emergency lighting fixture in the emergency generator room.
Engineering › Steering Gear System › Piping
Issued 14 May 2017 Resolved
Hydraulic leaks identified at all hard line connections in the steering gear system.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 14 May 2017 Resolved
Upper Bearing of Ships Shaft log is leaking oil.
Action required: 705 - Other - as specified
Resolved 19 May 2017
Resolution: Long term engineering condition issued to be rectified at the vessel next dry-dock. Additional monitoring procedures implemented to the satisfaction of class.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 14 May 2017 Resolved
Main engine sea water cooling pump has a failing mechanical seal.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 14 May 2017 Resolved
Main engine has jacket water leak on #5 cylinder. Class added #2 cylinder leaking the same.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Electrical › Electric Supply System (service) › Cable
Issued 14 May 2017 Resolved
Vent fan for the paint locker has exposed bare wire requiring renewal.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2017
Resolution: Class report received attesting to the proper repairs of the exposed wiring.
Accommodation/Occupational Safety › Ventilation › General
Issued 14 May 2017 Resolved
SPace ventilation in the Bosun's store is inoperable.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 May 2017 Resolved
Weld has been tripped on the guard rail in way of the main engine.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2017
Resolution: Received class report attesting to renewal of the tripped weld identified.
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 14 May 2017 Resolved
Public water closet on deck C drains onto the floor. 33 USC 1221(b)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2017
Resolution: Received class report attesting to proper repairs of the wash basin.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 14 May 2017 Resolved
Garbage record book was found with 4 pages not signed and certified by the captain.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Deficiency corrected on the spot.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 14 May 2017 Resolved
High level and overfill alarms are stencilled red. Re-mark the visual communications in black lettering.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2017
Resolution: Received Class report attesting to the proper marking.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 May 2017 Resolved
1" stud is missing from the vapor flange.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 19 May 2017
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 May 2017 Resolved
VCS flange was not properly painted Red/yellow/Red.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2017
Resolution: Deficiency corrected on the spot.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 14 May 2017 Resolved
Recommend internal audit be submitted to the Coast Guard.
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 10 February 2022
Navigation › Collision/Grounding Avoidance › Radar
Issued 1 March 2009 Resolved
Vessel became aware of malfunctioning 3-CM radar upon inbound transit to El Segundo Lightering Area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2009
Resolution: Rec''d tech report, all sat
Construction/Loadline › Markings › Load Line Mark
Issued 20 March 2007 Resolved
Vessels load line mark not permanately affixed nor did it match the vessel's Load Line certificate. Class to provide attestation to proper and accurate marking on boat port and starboard sides.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2007
Resolution: Class report provided attesting to new load line and the vesse''s change in DWT.
Construction/Loadline › Markings › Summer Load Line
Issued 3 May 2006 Resolved
Load line not permanently marked with summer line in accordance with load line certificate. Deficiency is due AFTER drydock in Sep '06.
Due 1 October 2006
Resolved 2 October 2006
Resolution: Received class report from BV satisfying requirement.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 10 November 2004 Resolved
The last ten meters of the safe access to tanker bow is missing due to bad weather in transit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 22 November 2004
Resolution: cleared via class report
Deck/Cargo › Towing › Tackle
Issued 10 November 2004 Resolved
Vessel's emergency towing arrangement forward is inoperative, due to bad weather.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 November 2004
Resolution: cleared via class report
Deck/Cargo › Mooring/Anchoring › Winch
Issued 10 November 2004 Resolved
Anchor windlass hydraulic motors inoperative due to bad weather. Water entered into the forward bosum locker and damaged the electrical panel to the windlass'.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 November 2004
Resolved 22 November 2004
Resolution: cleared via class report
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 10 November 2004 Resolved
Forward 6 person liferaft is missing due to bad weather. Needs to be replaced to the satisfaction of class prior to international voyage.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 November 2004
Resolved 22 November 2004
Resolution: cleared via class report

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.