Records from 2017 to 2022. Most recent: inspection, 12 April 2022.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 February 2022
Resolved
07126-Fire Safety-Means shall be provided to control leaks of flammable liquids. PSCO noticed excess fuel oil on SSDG #1 & #2 coming #7 cylinder & by fuel pumps.
74 SOLAS (14) II-2/4.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2022
Resolved 17 February 2022
Resolution: Lloyds provided documentation and proof of corrective actions that were up to USCG standards. Deficiency cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 February 2022
Resolved
09219-Working Conditions-Surfaces with temperatures of 220 C which may be impinged as a result of fuel system failure shall be properly insolated. PSCO noticed lagging missing from #3 SSDG exhaust manifold.
74 SOLAS (14) II-2/4.2.2.6.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2022
Resolved 12 April 2022
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 14 May 2017
Resolved
Engine Room Alarm system is currently provided with power from the main ships supply due to a faulty converter. Ship to provide documentation from the technician identifying the propblem and class documentation attesting an adequate repair proposal.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 14 May 2017
Resolved
Written procedure could not be provided to identify the specifc steps to properly demonstrate the required IGS system shutdowns and associated alarms.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Received Class report. Written procesdures now provided for the ships crew regarding proper procedures for the IGS system.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 14 May 2017
Resolved
IGG/IGS manual not updated to reflect the generator being decommissioned in 2014.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Class endorsed the IGS/IGG manual as approved prior to completion of USCG examination.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 14 May 2017
Resolved
Steering Gear local rudder angle indicator displays readings 10 degress error.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 May 2017
Resolved
All Portable and semi portable extinguishers had defective, missing, or broken brackets and securing arrangments.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Fire Fighting › Fire Hoses › Condition
Issued 14 May 2017
Resolved
Fire hoses in Engine Room are wasted and worn.
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 19 May 2017
Resolution: Received Class report attesting to the renewal of all fire hoses within the engine room space.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 May 2017
Resolved
Emergency Lighting fixture above the emergency generator room panel is inoperable.
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 19 May 2017
Resolution: Received Class report attesting to the proper operation of the emergency lighting fixture in the emergency generator room.
Engineering › Steering Gear System › Piping
Issued 14 May 2017
Resolved
Hydraulic leaks identified at all hard line connections in the steering gear system.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 14 May 2017
Resolved
Upper Bearing of Ships Shaft log is leaking oil.
Action required: 705 - Other - as specified
Resolved 19 May 2017
Resolution: Long term engineering condition issued to be rectified at the vessel next dry-dock. Additional monitoring procedures implemented to the satisfaction of class.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 14 May 2017
Resolved
Main engine sea water cooling pump has a failing mechanical seal.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 14 May 2017
Resolved
Main engine has jacket water leak on #5 cylinder. Class added #2 cylinder leaking the same.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Electrical › Electric Supply System (service) › Cable
Issued 14 May 2017
Resolved
Vent fan for the paint locker has exposed bare wire requiring renewal.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2017
Resolution: Class report received attesting to the proper repairs of the exposed wiring.
Accommodation/Occupational Safety › Ventilation › General
Issued 14 May 2017
Resolved
SPace ventilation in the Bosun's store is inoperable.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 10 February 2022
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 May 2017
Resolved
Weld has been tripped on the guard rail in way of the main engine.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2017
Resolution: Received class report attesting to renewal of the tripped weld identified.
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 14 May 2017
Resolved
Public water closet on deck C drains onto the floor. 33 USC 1221(b)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2017
Resolution: Received class report attesting to proper repairs of the wash basin.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 14 May 2017
Resolved
Garbage record book was found with 4 pages not signed and certified by the captain.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Deficiency corrected on the spot.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 14 May 2017
Resolved
High level and overfill alarms are stencilled red. Re-mark the visual communications in black lettering.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2017
Resolution: Received Class report attesting to the proper marking.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 May 2017
Resolved
1" stud is missing from the vapor flange.
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 19 May 2017
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 May 2017
Resolved
VCS flange was not properly painted Red/yellow/Red.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2017
Resolution: Deficiency corrected on the spot.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 14 May 2017
Resolved
Recommend internal audit be submitted to the Coast Guard.
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 10 February 2022