← All vessels
BW LARA
BW LARA is a 2003 tank ship. The Coast Guard has recorded 25 inspections since 2004, most recently in April 2022, along with 29 deficiencies and 6 operational controls.
Records from 2004 to 2022. Most recent: inspection, 12 April 2022.
- Built
- 2003
- Last inspected
- 12 April 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 29 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9269257 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V2885
728461
Flag
SINGAPORE
—
Maury page id
psix-728461
Inspections, by type
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it22047 - Convention (Subpart B), Net Ton
73496 - Dead Weight, Ton
88869 - Displacement, Ton
42011 - Convention (Subpart B), Gross Ton
73496 - Dead Weight, Ton
88869 - Displacement, Ton
42011 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 25
12 April 2022
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7429738
16 February 2022
COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7394306
10 February 2022
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7394251
14 May 2017
Deficiency Check · COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6145755
12 August 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5214482
9 May 2014
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4854498
28 April 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3463162
1 March 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3425851
6 November 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3358418
3 November 2008
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3356740
21 March 2007
Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2895209
20 March 2007
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2891555
19 March 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2890855
17 March 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2889846
2 October 2006
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2791697
3 May 2006
Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2635716
7 April 2006
Type not recorded
No type recorded · MARITIME SECURITY RESPONSE TEAM WEST · Activity 2619834
17 October 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2516420
14 July 2005
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2426940
22 May 2005
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2364880
24 April 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2341886
20 April 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2339382
27 February 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2300304
23 November 2004
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2246590
10 November 2004
COC-TVE Renew · ISPS II Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2235945
Deficiency record · 29
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 February 2022
Resolved
07126-Fire Safety-Means shall be provided to control leaks of flammable liquids. PSCO noticed excess fuel oil on SSDG #1 & #2 coming #7 cylinder & by fuel pumps.
74 SOLAS (14) II-2/4.1.1
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 February 2022
Resolved
09219-Working Conditions-Surfaces with temperatures of 220 C which may be impinged as a result of fuel system failure shall be properly insolated. PSCO noticed lagging missing from #3 SSDG exhaust manifold.
74 SOLAS (14) II-2/4.2.2.6.1
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 14 May 2017
Resolved
Engine Room Alarm system is currently provided with power from the main ships supply due to a faulty converter. Ship to provide documentation from the technician identifying the propblem and class documentation attesting an adequate repair proposal.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 14 May 2017
Resolved
Written procedure could not be provided to identify the specifc steps to properly demonstrate the required IGS system shutdowns and associated alarms.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 14 May 2017
Resolved
IGG/IGS manual not updated to reflect the generator being decommissioned in 2014.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 14 May 2017
Resolved
Steering Gear local rudder angle indicator displays readings 10 degress error.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 May 2017
Resolved
All Portable and semi portable extinguishers had defective, missing, or broken brackets and securing arrangments.
Fire Fighting › Fire Hoses › Condition
Issued 14 May 2017
Resolved
Fire hoses in Engine Room are wasted and worn.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 May 2017
Resolved
Emergency Lighting fixture above the emergency generator room panel is inoperable.
Engineering › Steering Gear System › Piping
Issued 14 May 2017
Resolved
Hydraulic leaks identified at all hard line connections in the steering gear system.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 14 May 2017
Resolved
Upper Bearing of Ships Shaft log is leaking oil.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 14 May 2017
Resolved
Main engine sea water cooling pump has a failing mechanical seal.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 14 May 2017
Resolved
Main engine has jacket water leak on #5 cylinder. Class added #2 cylinder leaking the same.
Electrical › Electric Supply System (service) › Cable
Issued 14 May 2017
Resolved
Vent fan for the paint locker has exposed bare wire requiring renewal.
Accommodation/Occupational Safety › Ventilation › General
Issued 14 May 2017
Resolved
SPace ventilation in the Bosun's store is inoperable.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 May 2017
Resolved
Weld has been tripped on the guard rail in way of the main engine.
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 14 May 2017
Resolved
Public water closet on deck C drains onto the floor. 33 USC 1221(b)
Documentation › Logs/Records › Garbage Recordkeeping
Issued 14 May 2017
Resolved
Garbage record book was found with 4 pages not signed and certified by the captain.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 14 May 2017
Resolved
High level and overfill alarms are stencilled red. Re-mark the visual communications in black lettering.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 May 2017
Resolved
1" stud is missing from the vapor flange.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 May 2017
Resolved
VCS flange was not properly painted Red/yellow/Red.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 14 May 2017
Resolved
Recommend internal audit be submitted to the Coast Guard.
Navigation › Collision/Grounding Avoidance › Radar
Issued 1 March 2009
Resolved
Vessel became aware of malfunctioning 3-CM radar upon inbound transit to El Segundo Lightering Area.
Construction/Loadline › Markings › Load Line Mark
Issued 20 March 2007
Resolved
Vessels load line mark not permanately affixed nor did it match the vessel's Load Line certificate. Class to provide attestation to proper and accurate marking on boat port and starboard sides.
Construction/Loadline › Markings › Summer Load Line
Issued 3 May 2006
Resolved
Load line not permanently marked with summer line in accordance with load line certificate. Deficiency is due AFTER drydock in Sep '06.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 10 November 2004
Resolved
The last ten meters of the safe access to tanker bow is missing due to bad weather in transit.
Deck/Cargo › Towing › Tackle
Issued 10 November 2004
Resolved
Vessel's emergency towing arrangement forward is inoperative, due to bad weather.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 10 November 2004
Resolved
Anchor windlass hydraulic motors inoperative due to bad weather. Water entered into the forward bosum locker and damaged the electrical panel to the windlass'.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 10 November 2004
Resolved
Forward 6 person liferaft is missing due to bad weather. Needs to be replaced to the satisfaction of class prior to international voyage.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.