MAURY USCG vessel records Sign in
← All vessels

SHANDONG WEIHE

SHANDONG WEIHE is a 2004 tank ship. The Coast Guard has recorded 23 inspections since 2004, most recently in January 2022, along with 8 deficiencies and 4 operational controls.

Records from 2004 to 2022. Most recent: inspection, 27 January 2022.

Built
2004
Last inspected
27 January 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9284726 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
728520
Flag
HONG KONG
—
Maury page id
psix-728520

Inspections, by type

…with no type recorded7
Years with a record 11 calendar years (2004–2022)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11645 - Convention (Subpart B), Net Ton
45898 - Dead Weight, Metric Ton
54786 - Displacement, Metric Ton
28059 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

27 January 2022 PSC B · COC-TVE Annual · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7383778
8 September 2021 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7307889
7 January 2021 PSC B · Administrative Inspection · COC-TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7119037
23 April 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6130737
6 February 2017 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6083602
16 January 2017 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6067651
28 September 2015 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5730144
28 December 2011 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4213927
15 December 2010 Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3910993
20 November 2010 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3892281
15 October 2008 COC-TVE Renew
Administrative · Activities Europe · Activity 3346755
30 July 2008 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3283962
19 November 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3100918
17 October 2007 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3077577
16 October 2006 MARPOL Annex V Examination · COC-TVE Renew · MARPOL Annex I Examination · MARPOL Annex II Examination · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2801402
4 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2701257
3 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2699494
29 November 2005 MARPOL Annex V Examination · MARPOL Annex I Examination · COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2542339
28 November 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2541999
4 April 2005 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2326112
10 November 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2238217
10 November 2004 ISPS II Exam · COC-TVE Renew
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2239046
5 November 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2248038

Deficiency record · 8

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 27 January 2022 Resolved
06105- TANKER SHALL BE EQUIPPED WITH AT LEAST ONE PORTABLE INSTRUMENT FOR MEASURING FLAMMABLE VAPOUR CONCENTRATIONS, TOGETHER WITH A SUFFICIENT SET OF SPARES. PSCO OBSERVED PORTABLE GAS DETECTION OF ALL THAT ARE AVAILABLE WERE FOUND TO NOT BE PROPERLY WORKING AND/OR CALIBRATED. 74SOLAS (09)II-2/4.5.7.1
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2022
Resolved 28 January 2022
Resolution: Received proper class documentation attesting to deficiency issued.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 January 2021 Resolved
VESSEL HAD A SMALL HOLE IN DECK FOAM PIPPING ON DECK CAUSING A LEAK. VESSEL PLACED PATCH OVER HOLE. SOLAS 74(2004) CH II REG 26
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 January 2021
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 7 January 2021 Resolved
THE INCINERATOR CASING AHS A 12CM CRACK ON THE TOP ROGHT CORNER, 10CM CRACK CENTER LOWER DOOR, 10CM CRACK ON THE TOP RIGHT CORNER, AND A 10 CM CRACK ON THE BOTTOM LEFT CORNER. SOLAS 74(2004) CH II-I REG 26
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 September 2021
Resolution: Received Class survey attesting to repair of steam line. see attached survey in documents.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 January 2021 Resolved
VESSEL HAS SMALL LEAK ON STEAM PIPE ON CARGO DECK BELOW FIRE MONITOR SOLAS 74(2014) CH I REG II Class imposed due date of 2/7/21
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 September 2021
Resolution: Received Class survey attesting to repair of steam line. See attached survey in documents.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 16 January 2017 Resolved
1099- Other –(alarms-signals)The condition that vessels cargo tank overfill alarm (98%) is nor operational due to a failed circuit board on control module a means to determine overfill level for cargo system is required to prevent over pressurization of the tank. Observed the overfill alarm would not operate properly. Solas 14 II-2 Part C Reg. 11.6.3.1 46CFR 39.2007
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 23 April 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 20 November 2010 Resolved
Cargo pipes need to be tested to 1.5 times it's maxium allowable working pressure.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 December 2010
Resolution: Vessel provided survey report that the Cargo Pipes had been tested to 1.5 times it''s maximum allowable working pressure.
Lifesaving › Launching Appliances › Davit
Issued 20 November 2010 Resolved
Vessel had difficulty in recovering lifeboat to stored postion. Every launching appliance shall be able to recover the lifeboat with crew.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 December 2010
Resolution: Vessel provided survey report showing that the launching appliance had been repaired.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 17 October 2007 Resolved
Number three (3) cargo tank overfill alarm electrical conduit/pipe holed. *Pin hole temp repaired with fiberglass resin and cloth. (action taken) 70a+c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 November 2007
Resolution: Received class report attesting to proper repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.