Records from 2012 to 2026. Most recent: inspection, 24 March 2026.
Inspection history · 22
24 March 2026
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8331456
25 February 2025
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8078385
13 November 2024
Deficiency Check · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8034123
20 March 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7881698
17 April 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7668784
7 December 2022
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7605950
8 November 2022
Drydock Exam · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7590662
28 April 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7439899
21 March 2022
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7415686
3 August 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7276674
17 March 2021
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7153951
11 November 2020
Drydock Exam · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7093721
9 August 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7029449
18 February 2020
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6908723
2 October 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6828194
9 April 2019
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6658337
23 October 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6566902
22 May 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6420545
2 May 2018
DAPI Audit · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6404331
17 April 2017
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6126463
1 November 2016
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6033931
12 May 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5874778
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 March 2026
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. MI found wingnuts on the generator battery in the engine room and the console battery in the pilot house.
46 CFR 183.350(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2026
Resolved 9 April 2026
Resolution: Operator emailed MI a picture of permanent connectors at the battery terminals.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 March 2026
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. MI found a plastic trash bin in the main cabin space.
46 CFR 177.405(f)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 24 March 2026
Resolution: Operator replaced plastic trash bin while MI was onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 February 2025
Resolved
A mechanical, manually operated device to assist in launching a survival craft must be provided if:
(1) The survival craft weights more than 90.7 kilograms (200 pounds); and
(2) The survival craft requires lifting more than 300 vertical millimeters (one vertical foot) to be launched. IBA weighing greater than 200 lbs is stowed in a manner in which it would need to be lifted higher than one foot to deploy overboard. Propose adequate arrangement plan for approval and perform installation within 6 months. 46 CFR 180.130(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2025
Resolved 1 April 2025
Resolution: Accepted video of lifting/launching arrangement.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 25 February 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 2 April 2025
Resolution: Accepted photo of updated license.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 March 2024
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. The pressure gauge did not work.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2024
Resolved 2 April 2024
Resolution: Vsl sent satisfactory video of new pressure gauge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The retroreflective tape on the life ring buoy needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2024
Resolved 8 April 2024
Resolution: Vessel representative sent satisfactory photo showing new retroreflective tape on the life ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 March 2024
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. There were 02 deficiencies identified on the life float:
1. The Type II SOLAS retroreflective tape needs to be replaced
2. One of the grab line attachments was deteriorated and unsecure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2024
Resolved 2 April 2024
Resolution: Vessel rep sent satisfactpry evidence of new tape and grab line attachment.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 March 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication. The Coast Pilot was out-dated and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2024
Resolved 25 March 2024
Resolution: Vsl sent satisfactory photo showing updated coast pilot onboard.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 20 March 2024
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. The magnetic compass did not illuminate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2024
Resolved 25 March 2024
Resolution: Vsl sent satisfactory photo of magnetic compass illuminated
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 March 2024
Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. There were several instances of welding defects identified in the fore peak. Repair prior to next credit drydock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 21 November 2024
Resolution: Operator had identified weld defects in the fore peak fixed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 March 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible. The vessel did not have up to date paper charts on-board the vessel.
46 CFR 184.420 (a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 30 March 2022
Resolution: Received photos of the newly updated paper charts.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 March 2021
Resolved
All vessels with overnight accommodations must be equipped with a general alarm system. The public address system required by 184.610 of this chapter may be used to sound the general alarm signal. The vessel's public address system was not audible in the accommodations space while the vessel was operating. Public address system speaker or general alarm must be installed in the accommodation space prior to carriage of overnight passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 August 2021
Resolution: Verified PA system operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 March 2021
Resolved
All mattresses must comply with either: the US Department of Commerce "Standard for Mattress Flammability" and not contain polyurethane foam; or IMO Resolution A.688(17). Mattresses did not comply with either standard and must be replaced with mattresses that comply with the standard prior to carriage of overnight passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 23 June 2022
Resolution: Overnight passenger allowance removed from COI.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 March 2021
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who is directly involved in the SMI. Alcohol test strips carried on board the vessel were expired. Expired alcohol testing devices must be replaced with new, unexpired testing devices.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2021
Resolved 29 March 2021
Resolution: alcohol testing devices purchased and onboard
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 March 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Supervisory personnel had not received required training. Employer must complete required training with supervisory personnel and present evidence of training completion
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2021
Resolved 29 March 2021
Resolution: Captain completed required training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2021
Resolved
When the flexible section of a fuel fill pipe is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. The vessel did not have a bonding connector on the flexible fuel fill pipe. A conductor must be installed in accordance with regulations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2021
Resolved 29 March 2021
Resolution: Bonded conductor installed on fuel fill.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2021
Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Fuel filter installed on the vessel's generator is non-steel construction and does not have a flame shield installed. A flame shield must be installed in accordance with regulations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2021
Resolved 29 March 2021
Resolution: Marine style steel fuel filter installed on generator.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 March 2021
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. The penetration between the tank room and the engine room is not watertight. This penetration must be made watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2021
Resolved 29 March 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 March 2021
Resolved
During the internal structural examination, an incomplete weld was identified on stringer forward of starboard engine. Stringer must be welded using appropriate techniques to obtain a full penetration weld on both sides of the joint.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2021
Resolved 19 April 2021
Resolution: Weld repaired IAW 6-78.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 February 2020
Resolved
A vessel on an oceans route must carry either six hand red flares or six hand orange smoke distress signals or a hand red flare distress signal may be substituted for any of the hand orange smoke distress signals. The appropriate number or substitutions of distress flares not onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2020
Resolved 4 March 2020
Resolution: Vessel provided a picture of the new flares onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 February 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. No approved or equivalent first-aid kit onboard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2020
Resolved 4 March 2020
Resolution: Vessel shared a picture showing the new first aid kit onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 February 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date nautical charts and publications or extract from the publications. Updated publications or extracts not onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2020
Resolved 4 March 2020
Resolution: Vessel provided proof that new charts had been placed on the vessel.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 18 February 2020
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician once every five years. The vessel Communications Act Safety Radiotelephony Certificate expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2020
Resolution: Saw a picture of the FCC certificate.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 February 2020
Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
Waste receptacles onboard constructed from a combustible material.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2020
Resolved 9 March 2020
Resolution: Saw noncombustible trash cans
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 February 2020
Resolved
The inspection and maintenance of survival craft shall be logged or otherwise documented. The weekly and monthly survival craft maintenance listed in 46 CFR Subpart G not logged or documented. Each EPIRB must be tested monthly and the EPIRB test required shall be logged or otherwise documented. The monthly EPRIB test not logged or documented.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 February 2020
Resolution: Corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 9 April 2019
Resolved
Incomplete weld identified in forward void, port side, where most forward edge of deck meets the hull. Repair during next dry dock. See deficiency documents for photos. 46 CFR 176.610(b)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 November 2020
Resolved 16 November 2020
Resolution: Area of concern has been ground out and re-welded. See picture in documents tab under deficiency history.
Communications › Radio Communications › EPIRB
Issued 3 May 2018
Resolved
The vessel's EPIRB battery is expired. Either the battery or the EPIRB itself must be replaced. Vessel operations limited to no more than 3NM from shore until a new battery or EPIRB is properly installed on the vessel.
46 CFR 185.728(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2018
Resolved 4 May 2018
Resolution: Operator recieved new NOAA-registered EPIRB and installed properly on board the vessel
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2018
Resolved
Vessel has only one chart on board and it does not cover all areas of operation. It needs to obtain updated and accurate charts for all areas of operation
46 CFR 184.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2018
Resolved 17 May 2018
Resolution: Updated charts were received by owner and landed on the vessel.
Construction/Loadline › Hull › Weld
Issued 3 May 2018
Resolved
In the forward void, repair cracked weld located on the most-forward section of the port side where the deck meets the bulkhead. Additionally, repair welds for two of the center longitudinal deck stiffeners that are just aft of the first frame so that they lay flush with the overhead.
Repairs must be made prior to completion of next credit drydock.
46 CFR 176.610(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 9 April 2019
Resolution: Revised deficiency and reissued under activity 6658337.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 3 May 2018
Resolved
Alcohol test strips for post-casualty testing are expired and require replacement.
46 CFR 4.06-3(a)(i)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: Vessel rep purchased new stips prior to completion of inspection.