This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
150 - Regulatory (Subpart C or D), Gross Ton
150 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-72909
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
Stability › Intact Stability (when using lifting gear) › General
Issued 14 August 2017Resolved
Prove compliance with stability requirements in 46 CFR Subchapter S
Action required: 705 - Other - as specified
Due 14 August 2017
Resolved 7 July 2026
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 August 2014Resolved
Vessel was using an extension cord and a powerstrip in house of vessel.
Due 27 August 2014
Resolved 27 August 2014
Resolution: Corrected on Spot
Lifesaving › Lifebuoys › Serviceable
Issued 27 August 2014Resolved
2 Lifebouys on board were found unservicable.
Due 27 August 2014
Resolved 27 August 2014
Resolution: Old ones removed and replaced with new ones.
Construction/Loadline › Hull › Bottom Plating
Issued 23 September 2013Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGE ON THE BOW RAKE DUE TO ALLISION TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. Prior to departure from Allied shipyard to the satisfaction of the cognizant OCMI.
Action required: 705 - Other - as specified
Resolved 14 August 2017
Resolution: Repairs made and inspected by activity #4723505, but not resolved. Visually inspected outer plating and voids, all sat.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 23 July 2013Resolved
Pressure relief valve not tested
Due 23 July 2013
Resolved 23 July 2013
Resolution: Replaced relilef valve
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 July 2013Resolved
Port side life ring water light housing was cracked.
Due 23 July 2013
Resolved 23 July 2013
Resolution: replaced water light
Lifesaving › Lifebuoys › Serviceable
Issued 23 July 2013Resolved
STBD side life buoy was not serviceable.
Due 23 July 2013
Resolved 23 July 2013
Resolution: replaced lifebuoy
Lifesaving › Lifebuoys › Serviceable
Issued 23 July 2013Resolved
Port side lifebuoy was not serviceable
Due 23 July 2013
Resolved 23 July 2013
Resolution: replaced lifebuoy
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 September 2011Resolved
Generator battery missing protective box and cover.
Action required: 705 - Other - as specified
Due 7 October 2011
Resolved 1 October 2011
Resolution: Generator battery installed with protective box and cover.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 31 July 2008Resolved
Face plate not seated correctly due to over stuffed box.
Action required: 705 - Other - as specified
Resolved 31 July 2008
Resolution: Electrician opened box and properly seated receptacle and replaced cover.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 31 July 2008Resolved
Diesel tank had drain outlet with no plug.
Action required: 705 - Other - as specified
Resolved 31 July 2008
Resolution: Threaded plug put into the end of the fitting.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 31 July 2008Resolved
Vessel has two (2) independent tanks mounted on the forward deck. These tanks do not meet 46CFR32.60-30 in that they are mounted on deck boards, which does not allow 15 inches of clearance to provide inspection of the bottom of the tank, and the tanks are secured to the deck with four (4) bolts instead of a supported saddle or foundation.
Action required: 705 - Other - as specified
Due 6 November 2008
Resolved 29 July 2010
Resolution: Independant Tank modification (addition of support foundation) has been approved by Local OCMI.
Construction/Loadline › Hull › Hull Plating
Issued 23 May 2008Resolved
Provide PE report analysis as per 46 CFr 31.10-21a.
Due 22 October 2008
Resolved 25 September 2008
Resolution: PE report provided from 30 yr midbody gaugings and scanned into documents section.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 September 2004Resolved
Lights attached to end of lifering line. Provide separate line with a clip to attach to lifering.
Condition: Improper Installation
Due 23 September 2004
Resolved 23 September 2004
Electrical › Electric Generation Source (service) › Ground Detection
Issued 4 December 2003Resolved
Resolve issues with Generator in order to get MSC to approve vsl system.
Due 9 January 2004
Resolved 9 January 2004
Resolution: Resolved all issues and recieved approval letter for system
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 December 2003Resolved
Vessel name needs to be changed with vessel documentation center in Falling Waters, WV
Due 23 March 2004
Resolved 24 February 2005
Resolution: Verified
Deck/Cargo › Cargo Heating
Issued 4 December 2003Resolved
Missing approval letter for TFH test procedures.
Due 4 December 2003
Resolved 4 December 2003
Resolution: Provided approval letter for test procedures and witnessed sat test of system.