SPIRIT OF KINGSTON

SPIRIT OF KINGSTON is a 2004 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 2004, most recently in May 2026, along with 56 deficiencies and 10 casualty investigations between 2010 and 2022.

Records from 2004 to 2026. Most recent: inspection, 7 May 2026.

Built
2004
Last inspected
7 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG9181
729459
Flag
UNITED STATES
338754000
Maury page id
psix-729459

Inspections, by type

…with no type recorded6
Years with a record 22 calendar years (2004–2026)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.6 ft × 25.5 ft × 7.9 ft
Registered tonnagegross 70 / net 47
ITC dimensions (L × B × D)65.6 ft × 25.5 ft × 7.9 ft
ITC tonnageNot recorded
BuilderALL AMERICAN MARINE INC · BELLINGHAM, WA, UNITED STATES · built 2004
Hull materialAluminum
PropulsionJet Drive
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it70 - Regulatory (Subpart C or D), Gross Ton
70 - Dead Weight, Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG9181MMSI 338754000 · active · compulsorily equipped · granted 1 July 2023, expires 30 July 2033
WDC3974MMSI 367017270 · expired · compulsorily equipped · granted 10 February 2005, cancelled 18 April 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 64

7 May 2026 Internal Structural Exam · Vessel Attendance · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8368050
4 June 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8153219
12 November 2024 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8035036
5 August 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7976445
2 May 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7905589
15 May 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7688531
7 December 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7605715
7 October 2022 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7573600
31 August 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7548751
25 July 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7516346
3 May 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7443420
29 March 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7161709
12 March 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7154977
3 April 2020 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6939629
25 March 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6931844
12 December 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6876926
25 November 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6860891
6 June 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6705591
15 March 2019 Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6642841
2 May 2018 COI Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6404252
16 April 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6392585
31 March 2018 Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6383566
28 March 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6380378
16 March 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6379965
23 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6360526
8 November 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6303378
6 June 2017 Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6167712
13 April 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6123664
13 March 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6093004
8 March 2016 Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5829534
21 October 2015 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5747658
25 August 2015 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5227111
22 August 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4962954
9 August 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4951611
9 August 2014 Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4952579
29 May 2014 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4873810
7 May 2014 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4852436
10 March 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4813942
10 March 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4815471
2 July 2012 Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4365287
2 July 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4390615
15 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4208990
27 January 2011 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3934512
7 January 2011 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3924428
18 October 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3872821
27 September 2010 Drydock Exam · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3864073
26 February 2010 Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3686203
12 February 2010 Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3679398
7 May 2009 Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3469611
5 May 2008 Annual Inspection · Deficiency Check · Internal Structural Exam · DAPI Audit · Drydock Exam · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3239107
10 April 2008 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3181540
3 July 2007 Deficiency Check · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2981910
17 May 2007 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2932928
24 April 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2914799
23 April 2007 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2914165
6 April 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2903004
5 July 2006 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2702363
28 June 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2694672
11 April 2006 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2622229
23 November 2005 Deadweight Survey · Construction Oversight · Plan Review "T" Boat · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2540593
28 June 2005 Special
Type not classified · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2407021
24 May 2005 Administrative Inspection · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2367404
12 May 2005 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2357302
14 December 2004 Initial Certification · Construction Oversight · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2259133

Deficiency record · 56

01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 12 November 2024 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. The vessels captain did not posses a current medical certificate.
Action required: 10 - Deficiency Rectified
Resolved 12 November 2024
Resolution: Operator replaced the mariner with another master.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 May 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel paper charts not updated and electronic charts had no tracking of current edition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 23 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 May 2024 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry six hand red flare distress signals [...] and six hand orange smoke distress signals. Vessel had 3 hand red flare and 3 hand orange smoke IAW lakes, bays, and sounds. Vessel route will be restricted to lakes, bays, and sounds until rectified.
Action required: 705 - Other - as specified
Due 16 May 2024
Resolved 23 May 2024
Resolution: Additional flares on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 May 2024 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material [...]. The Arrangement of the of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16): "Retro-reflective materials of sufficient width (5cm) should be applied around or on both sides of the body of the lifebuoy at four evenly-spaced points."
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2024
Resolved 23 May 2024
Resolution: Additional retro added.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 May 2024 Resolved
47 CFR 80.159(e)(1); Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Operator permits were not available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 23 May 2024
Resolution: Primary operators documentation sent to verify proper licensing.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 May 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 23 May 2024
Resolution: Posted EAP information as requested.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 May 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 23 May 2024
Resolution: Removed old inspection stickers.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 May 2024 Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. No stability letter was posted.
Action required: 10 - Deficiency Rectified
Resolved 23 May 2024
Resolution: Posted stability letter.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 March 2021 Resolved
A vessel must carry adequate and up-to-date charts. Vessel did not have up-to-date charts. Required to update the paper charts. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 16 April 2021
Resolution: Charts were updated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 March 2021 Resolved
Each life jacket must be marked with the vessel's name. Discovered 6 child life jackets that were not marked with the vessel's name. Required to label or remove from the vessel. 46 CFR 185.604 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 16 April 2021
Resolution: Vessel labeled the life jackets.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 March 2021 Resolved
MMSI number programmed into the vessels DSC radio is not the MMSI number from the current FCC Station License. Program DSC radio with vessels assigned MMSI number from the FCC Station License. 46 CFR 184.502 47 CFR 80.103
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 16 April 2021
Resolution: Confirmed correct GPS position and MMSI. All sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 March 2021 Resolved
DSC equipped radio is not receiving position data from installed navigation equipment. FCC regulations require this connection if navigational equipment is installed. Properly connect DSC radio to installed GPS. 46 CFR 184.502 47 CFR 80.1085(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 16 April 2021
Resolution: Confirmed correct GPS position and MMSI. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 April 2020 Resolved
Expired IBA on vessel waiting to be serviced and inspected. Until IBA is properly serviced and validated, vessel is restricted in operating no greater than one mile from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2020
Resolved 16 April 2020
Resolution: Vessel rep sent photos of life raft servicing report and decal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2020 Resolved
Retro-reflective tape on three ring buoys not applied around or on both sides of the body of the lifebuoy at four evenly-spaced points. Apply Type II retro-reflective tape that meets the minimum technical specifications as laid out in IMO Resolution A.658(16) at four evenly-spaced points.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2020
Resolved 15 April 2020
Resolution: Applied Type II retro-reflective tape that meets the minimum technical specifications as laid out in IMO Resolution A.658(16) at four evenly-spaced points.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2019 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Discovered a bulkhead penetration in the #4 watertight bulkhead that is leaking and deteriorated due to corrosion from dissimilar metals. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2019
Resolved 9 December 2019
Resolution: Received a call and email from [name withheld] regarding the bulkhead penetration in the #4 watertight bulkhead that was leaking and deteriorated due to corrosion from dissimilar metals. The pipe has been replaced and all appears sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 March 2019 Resolved
02108 - Conductors must be protected in accordance with their current carrying capacities. If the allowable current carrying capacity does not correspond to a standard device size, the next larger overcurrent device may be used provided it does not exceed 150 percent of the conductor current carrying capacity. Installed overcurrent protection is greater than approved drawing permits. - 46 CFR 183.380(d) - 17.C
Action required: 705 - Other - as specified
Due 15 May 2019
Resolved 25 November 2019
Resolution: Overcurrent protection now matches the labels and drawings. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 March 2019 Resolved
02108 - Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors. / Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Port collision void has anchor motor w/ exposed electrical conductors. - 46 CFR 183.200 / 46 CFR 183.340(g) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 March 2019 Resolved
02108 - Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Wires spliced in port collision void using electrical tape. - 46 CFR 183.340(g) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 March 2019 Resolved
02108 - Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Port tank sensor wires have dead-ends and exposed junctions. - 46 CFR 183.340(g) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 15 March 2019 Resolved
02115 - Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Hole in bulkhead between port forward void and tank room, center top. - 46 CFR 179.320(a) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 March 2019 Resolved
02106 - Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. A positive action valve or cock that is located as close as possible to the hull is an acceptable means for complying with [the above]. Hull penetrations with plastic caps and check valves. - 46 CFR 179.350 - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 March 2019 Resolved
03110 - A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: (1) A hatch on a watertight trunk that extends at least 305 millimeters (12 inches) above the weather deck; (2) A hatch in a cabin top; and (3) A hatch on a vessel that operates only on protected waters. Stern trim void hatches not watertight. - 46 CFR 179.360(a) - 50.C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 March 2019 Resolved
02101 - A weathertight door must be provided for each opening located in a deck house or companionway. Weathertight door gaskets to main engine rooms deteriorated at base. – 46 CFR 179.360(d) – 50.C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 15 March 2019 Resolved
09106 - Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Modifications to sewage system with several pipes cut and left open. - 46 CFR 176.700(a) - 50.C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 March 2019 Resolved
13101 - Pipes used for wet exhaust lines must be Schedule 80 or corrosion-resistant material and adequately protected from mechanical damage. Port main engine exhaust cooling hose collapsed. - 46 CFR 182.430(d) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 March 2019 Resolved
13102 - Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Starboard generator exhaust cooling hose cracked due to excessive unsupported bending. - 46 CFR 182.430(b) – 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 March 2019 Resolved
11131 - Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Life jacket donning placards do not match type onboard. - 46 CFR 185.516(a) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 March 2019 Resolved
13104 - Each fixed power bilge pump must be self priming. It may be driven off the main engine or other source of power. It must be permanently connected to the bilge manifold and may also be connected to the fire main. If of sufficient capacity, a power bilge pump may also serve as a fire pump. Starboard fixed power bilge pump would not take suction. - 46 CFR 182.520(c) - 10.C
Action required: 10 - Deficiency Rectified
Resolved 15 March 2019
Construction/Loadline › Penetrations › Valve Flange
Issued 31 March 2018 Resolved
Repair cracked weld in Port generator sea water intake through-hull valve flange prior to carrying passengers, to the satisfaction of attending marine inspectors. 46CFR176.804(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2018
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2018 Resolved
Pin hole found in port catameran on the inboard side approximately 2 inches above waterline. Hole located in same space as fuel tank. 46CFR176.700
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 6 April 2018
Resolution: Resolved per activity 6383566
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 16 March 2018 Resolved
Vessel is limited to 30 knots when significant wave height is greater then 1.5 ft. This restriction will remain in effect until the vessel is no longer on RICH PASSAGE 1 run, approx 2 weeks.
Action required: 705 - Other - as specified
Resolved 15 May 2018
Resolution: Vessel is no longer on the RICH PASSAGE 1 route and is back on it normal route.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 June 2017 Resolved
Pre-Engineered system failed to automatically shut down engines.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2017
Resolved 8 June 2017
Resolution: control panel for main engine shutdowns at pre-engineered fixed gas extinguishing system was reconfigured to activate engine shutdown at activation. Tested port and stbd E/R's- SAT.
Construction/Loadline › Structures › Superstructure
Issued 21 October 2015 Resolved
Vee out and reweld cracked weld on portside jet drive transom IAW 46CFR177.100.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 1 November 2015
Resolution: Cracked weld was veed out and rewelded. All sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 October 2015 Resolved
Vessel will be moving remote fuel shut off valves IAW 46CFR182.455(b)(4).
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 1 November 2015
Resolution: Completed 1NOV15, inspected 1DEC15. Operationally tested shutoff valves, all sat.
Engineering › Fuel Oil Service System › Filter
Issued 22 August 2014 Resolved
Replace cracked fuel oil filter casing, located on port side Main Engine prior to carrying passengers. 46 CFR 182.455(b)(5).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2014
Resolution: To the satisfaction of U.S. Coast Guard MI, cracked fitting was replaced with a new and thicker gauge of 1/4"; in addition 1/4" clearance between turbo air line and fuel housing accomplished by maintenance crew.
Engineering › Freshwater System (injector cooling) › Level Control
Issued 29 May 2014 Resolved
COMPLETE PERMANENT REPAIRS TO THE COOLING SYSTEM ON THE FORWARD STARBOARD ENGINE.
Action required: 705 - Other - as specified
Due 2 June 2014
Resolved 31 May 2014
Resolution: Vessel made appropriate repairs, replaced exhaust manifold.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 2 July 2012 Resolved
Replace in kind port auxiliary generator and prove proper operation to satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 6 July 2012
Resolution: Vessel replaced port auxiliary generator and proved proper operation to the satisfaction of the Marine Inspector.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 27 September 2010 Resolved
Clean oil out of bilges to reduce fire hazard, IAW 46 CFR 182.100. This must be done prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2010
Resolution: Bilges have been satisfactorily cleaned.
Engineering › Bilge Water Management System › Not Operational
Issued 27 September 2010 Resolved
Repair visual indicator for bilge high water alarm for port tank space IAW 46 CFR 182.530(c).
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2011
Resolved 7 January 2011
Resolution: LED in panel replaced, and lit when tested.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 27 September 2010 Resolved
Provide CPR cards for 50% of the crew
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 October 2010
Resolution: All crew provided CPR and first aid cards
Communications › Public Address System › Loudspeaker
Issued 27 September 2010 Resolved
Ensure all loudspeakers that are part of the public address system are functional.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2011
Resolved 27 January 2011
Resolution: Loudspeakers removed, serviced, and reinstalled. Public address system audible from all points on vessel.
Lifesaving › Inflatable Liferafts › Servicing
Issued 27 September 2010 Resolved
Provide servicing certificates for all liferafts.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2011
Resolved 27 January 2011
Resolution: Liferafts reserviced. New certificates provided.
Construction/Loadline › Hull › Hull Plating
Issued 27 September 2010 Resolved
Two separate sections of hull plating have over 25% wastage in places. Crop and renew.
Due 27 October 2010
Resolved 5 October 2010
Resolution: Hull renewed and tested. All sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 February 2010 Resolved
Perform underway Man overboard and fire drills prior to operation with passengers onboard IAW 46 CFR 185.520.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2010
Resolved 28 September 2010
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 12 February 2010 Resolved
Provide proof of proper IBA servicing prior to operation with passengers onboard IAW 46 CFR 185.730.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2010
Resolved 12 March 2010
Resolution: IBA''s serviced and labeled with valid inspection stickers.
Engineering › Fuel Oil Service System › Valve
Issued 12 February 2010 Resolved
Prove proper installation of fuel shutoff handles in main fuel tank space IAW 46 CFR 182.455 (b)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2010
Resolved 12 March 2010
Resolution: Aluminum flame shield installed at the fuel shutoff handles.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 28 May 2008 Resolved
Provide firefighting service certificate to show proof of fireboys being serviced
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 April 2008 Resolved
Vsl prohibited from operating until new to zone inspection is conducted.
Action required: 705 - Other - as specified
Due 10 April 2008
Resolved 28 May 2008
Engineering › Sea-water System (primary cooling) › Pump
Issued 3 July 2007 Resolved
Replace/repair stbd fwd R/W pump and demonstrate proper operation.
Action required: 705 - Other - as specified
Due 10 July 2007
Resolved 5 July 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 April 2007 Resolved
Provide service certificates.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2007
Resolved 6 April 2007
Resolution: Provided certificates for Portable fire extinguisher.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 April 2007 Resolved
Provide logs for training and dirlls.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2007
Resolved 17 May 2007
Resolution: Verified training log onboard.
Personnel › Training › First Aid/CPR
Issued 6 April 2007 Resolved
Provide valid CPR/First-aid card.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2007
Resolved 17 May 2007
Lifesaving › Inflatable Liferafts › Capacity
Issued 5 July 2006 Resolved
Vessel limited to 150 total persons on board to comply with D17 100% primary lifesaving requirement until operator provides Sector Juneau with exemption request letter to allow for 152 total persons.
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 10 July 2006
Resolution: Letter was provided to OCMI.
Communications › Radio Communications › EPIRB
Issued 5 July 2006 Resolved
Vessel required to provide proof of current NOAA registration of EPIRB prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2006
Resolved 5 July 2006
Resolution: Proof of registration provided to inspector.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 12 May 2005 Resolved
Resolve discrepancy between stability letter drafts and freeboards, and actual applied draft marks (draft markings appear in error); apply amidships minimum-freeboard markings (i.e. loading marks) as a temporary guideline prior to carrying passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 June 2005
Resolved 24 May 2005
Resolution: Assumed baseline was changed and a new stability letter issued by MSC-1 which allowed use of existing drafts with different limits.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 May 2005 Resolved
Secure coffee maker urn on upper deck.
Action required: 705 - Other - as specified
Due 12 June 2005
Resolved 24 May 2005
Resolution: Coffee urn secured by retaining cords per phone report from vessel master.

Casualty record · 10

18 October 2010Routine · role: Involved in a Marine Casualty · activity 3872821
2 July 2012Routine · role: Involved in a Marine Casualty · activity 4390615
9 June 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4624249
12 July 2013Routine · role: Involved in a Marine Casualty · activity 4654199
12 August 2013Routine · role: Involved in a Marine Casualty · activity 4685721
16 August 2013Routine · role: Involved in a Marine Casualty · activity 4690285
25 September 2013Routine · role: Involved in a Marine Casualty · activity 4729130
17 October 2013Routine · role: Involved in a Marine Casualty · activity 4738741
10 March 2014Routine · role: Involved in a Marine Casualty · activity 4815471
7 December 2022Routine · role: Involved in a Marine Casualty · activity 7605715
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.