Inspection history · 30
7 May 2026
Internal Structural Exam · Vessel Attendance · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8368050
4 June 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8153219
12 November 2024
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8035036
5 August 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7976445
2 May 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7905589
15 May 2023
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7688531
7 December 2022
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7605715
7 October 2022
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7573600
31 August 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7548751
25 July 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7516346
3 May 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7443420
29 March 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7161709
12 March 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7154977
3 April 2020
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6939629
25 March 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6931844
12 December 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6876926
25 November 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6860891
6 June 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6705591
15 March 2019
Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6642841
2 May 2018
COI Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6404252
16 April 2018
Administrative Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6392585
31 March 2018
Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6383566
28 March 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6380378
16 March 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6379965
23 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6360526
8 November 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6303378
6 June 2017
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6167712
13 April 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6123664
13 March 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6093004
8 March 2016
Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5829534
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 12 November 2024
Resolved
A person may not employ or engage an individual in
a position required to hold an MMC unless that
individual maintains a current medical certificate. The
vessels captain did not posses a current medical
certificate.
Action required: 10 - Deficiency Rectified
Resolved 12 November 2024
Resolution: Operator replaced the mariner with another master.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 May 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel paper charts not updated and electronic charts had no tracking of current edition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 23 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 May 2024
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry six hand red flare distress signals [...] and six hand orange smoke distress signals. Vessel had 3 hand red flare and 3 hand orange smoke IAW lakes, bays, and sounds. Vessel route will be restricted to lakes, bays, and sounds until rectified.
Action required: 705 - Other - as specified
Due 16 May 2024
Resolved 23 May 2024
Resolution: Additional flares on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 May 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material [...]. The Arrangement of the of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16): "Retro-reflective materials of sufficient width (5cm) should be applied around or on both sides of the body of the lifebuoy at four evenly-spaced points."
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2024
Resolved 23 May 2024
Resolution: Additional retro added.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 May 2024
Resolved
47 CFR 80.159(e)(1); Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Operator permits were not available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 23 May 2024
Resolution: Primary operators documentation sent to verify proper licensing.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 May 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 23 May 2024
Resolution: Posted EAP information as requested.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 May 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 23 May 2024
Resolution: Removed old inspection stickers.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 May 2024
Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. No stability letter was posted.
Action required: 10 - Deficiency Rectified
Resolved 23 May 2024
Resolution: Posted stability letter.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 March 2021
Resolved
A vessel must carry adequate and up-to-date charts. Vessel did not have up-to-date charts. Required to update the paper charts.
46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 16 April 2021
Resolution: Charts were updated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 March 2021
Resolved
Each life jacket must be marked with the vessel's name. Discovered 6 child life jackets that were not marked with the vessel's name. Required to label or remove from the vessel.
46 CFR 185.604 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 16 April 2021
Resolution: Vessel labeled the life jackets.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 March 2021
Resolved
MMSI number programmed into the vessels DSC radio is not the MMSI number from the current FCC Station License. Program DSC radio with vessels assigned MMSI number from the FCC Station License.
46 CFR 184.502
47 CFR 80.103
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 16 April 2021
Resolution: Confirmed correct GPS position and MMSI. All sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 March 2021
Resolved
DSC equipped radio is not receiving position data from installed navigation equipment. FCC regulations require this connection if navigational equipment is installed. Properly connect DSC radio to installed GPS.
46 CFR 184.502
47 CFR 80.1085(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 16 April 2021
Resolution: Confirmed correct GPS position and MMSI. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 April 2020
Resolved
Expired IBA on vessel waiting to be serviced and inspected. Until IBA is properly serviced and validated, vessel is restricted in operating no greater than one mile from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2020
Resolved 16 April 2020
Resolution: Vessel rep sent photos of life raft servicing report and decal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2020
Resolved
Retro-reflective tape on three ring buoys not applied around or on both sides of the body of the lifebuoy at four evenly-spaced points. Apply Type II retro-reflective tape that meets the minimum technical specifications as laid out in IMO Resolution A.658(16) at four evenly-spaced points.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2020
Resolved 15 April 2020
Resolution: Applied Type II retro-reflective tape that meets the minimum technical specifications as laid out in IMO Resolution A.658(16) at four evenly-spaced points.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2019
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Discovered a bulkhead penetration in the #4 watertight bulkhead that is leaking and deteriorated due to corrosion from dissimilar metals.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2019
Resolved 9 December 2019
Resolution: Received a call and email from [name withheld] regarding the bulkhead penetration in the #4 watertight bulkhead that was leaking and deteriorated due to corrosion from dissimilar metals. The pipe has been replaced and all appears sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 March 2019
Resolved
02108 - Conductors must be protected in accordance with their current carrying capacities. If the allowable current carrying capacity does not correspond to a standard device size, the next larger overcurrent device may be used provided it does not exceed 150 percent of the conductor current carrying capacity. Installed overcurrent protection is greater than approved drawing permits. - 46 CFR 183.380(d) - 17.C
Action required: 705 - Other - as specified
Due 15 May 2019
Resolved 25 November 2019
Resolution: Overcurrent protection now matches the labels and drawings. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 March 2019
Resolved
02108 - Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors. / Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Port collision void has anchor motor w/ exposed electrical conductors. - 46 CFR 183.200 / 46 CFR 183.340(g) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 March 2019
Resolved
02108 - Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Wires spliced in port collision void using electrical tape. - 46 CFR 183.340(g) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 March 2019
Resolved
02108 - Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Port tank sensor wires have dead-ends and exposed junctions. - 46 CFR 183.340(g) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 15 March 2019
Resolved
02115 - Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Hole in bulkhead between port forward void and tank room, center top. - 46 CFR 179.320(a) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 March 2019
Resolved
02106 - Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. A positive action valve or cock that is located as close as possible to the hull is an acceptable means for complying with [the above]. Hull penetrations with plastic caps and check valves. - 46 CFR 179.350 - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 March 2019
Resolved
03110 - A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: (1) A hatch on a watertight trunk that extends at least 305 millimeters (12 inches) above the weather deck; (2) A hatch in a cabin top; and (3) A hatch on a vessel that operates only on protected waters. Stern trim void hatches not watertight. - 46 CFR 179.360(a) - 50.C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 March 2019
Resolved
02101 - A weathertight door must be provided for each opening located in a deck house or companionway. Weathertight door gaskets to main engine rooms deteriorated at base. – 46 CFR 179.360(d) – 50.C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 15 March 2019
Resolved
09106 - Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Modifications to sewage system with several pipes cut and left open. - 46 CFR 176.700(a) - 50.C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 March 2019
Resolved
13101 - Pipes used for wet exhaust lines must be Schedule 80 or corrosion-resistant material and adequately protected from mechanical damage. Port main engine exhaust cooling hose collapsed. - 46 CFR 182.430(d) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 March 2019
Resolved
13102 - Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Starboard generator exhaust cooling hose cracked due to excessive unsupported bending. - 46 CFR 182.430(b) – 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 March 2019
Resolved
11131 - Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Life jacket donning placards do not match type onboard. - 46 CFR 185.516(a) - 16.C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 March 2019
Resolved
13104 - Each fixed power bilge pump must be self priming. It may be driven off the main engine or other source of power. It must be permanently connected to the bilge manifold and may also be connected to the fire main. If of sufficient capacity, a power bilge pump may also serve as a fire pump. Starboard fixed power bilge pump would not take suction. - 46 CFR 182.520(c) - 10.C
Action required: 10 - Deficiency Rectified
Resolved 15 March 2019
Construction/Loadline › Penetrations › Valve Flange
Issued 31 March 2018
Resolved
Repair cracked weld in Port generator sea water intake through-hull valve flange prior to carrying passengers, to the satisfaction of attending marine inspectors. 46CFR176.804(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2018
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2018
Resolved
Pin hole found in port catameran on the inboard side approximately 2 inches above waterline. Hole located in same space as fuel tank. 46CFR176.700
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 6 April 2018
Resolution: Resolved per activity 6383566
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 16 March 2018
Resolved
Vessel is limited to 30 knots when significant wave height is greater then 1.5 ft. This restriction will remain in effect until the vessel is no longer on RICH PASSAGE 1 run, approx 2 weeks.
Action required: 705 - Other - as specified
Resolved 15 May 2018
Resolution: Vessel is no longer on the RICH PASSAGE 1 route and is back on it normal route.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 June 2017
Resolved
Pre-Engineered system failed to automatically shut down engines.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2017
Resolved 8 June 2017
Resolution: control panel for main engine shutdowns at pre-engineered fixed gas extinguishing system was reconfigured to activate engine shutdown at activation. Tested port and stbd E/R's- SAT.