MAURY USCG vessel records Sign in
← All vessels

BULK NEWPORT

BULK NEWPORT is a 2003 freight ship. The Coast Guard has recorded 30 inspections since 2004, most recently in October 2022, along with 12 deficiencies — 4 with no resolution recorded — and 7 operational controls.

Records from 2004 to 2022. Most recent: inspection, 4 October 2022.

Built
2003
Last inspected
4 October 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9244611 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
729602
Flag
PANAMA
—
Maury page id
psix-729602

Inspections, by type

…with no type recorded7
Years with a record 13 calendar years (2004–2022)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it29862 - Convention (Subpart B), Gross Ton
18011 - Convention (Subpart B), Net Ton
52587 - Dead Weight, Metric Ton
60757 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

4 October 2022 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7571272
5 May 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7444848
21 March 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7409756
19 November 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7354205
17 August 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7281528
6 October 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7072479
28 September 2020 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7067118
22 September 2020 PSC B · Ballast Water Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7057503
17 October 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6836607
15 October 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6835136
15 October 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6835177
20 March 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6645974
13 March 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6641819
13 March 2019 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6642049
14 November 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6577162
22 December 2017 Deficiency Check
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6327930
19 December 2017 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6326727
10 October 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6284379
11 September 2016 PII Safety Exam · COE-Dockside · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5997533
26 June 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5919560
10 August 2015 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5211569
7 August 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5208540
13 December 2010 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3909678
9 December 2010 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3907649
9 March 2009 MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3426579
16 January 2008 PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3128953
23 June 2006 MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2682369
25 December 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2264602
16 November 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2242261
16 November 2004 PII Safety Exam · ISPS II Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2242924

Deficiency record · 12

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 4 October 2022 No resolution recorded
15101 The company should ensure that the policy is implemented and maintained at all levels of the organization, both ship and shore based. PSCO observed that crew in charge of garbage ,management has not follow garbage management plane and discharge cargo hold wash within special area. 74SOLAS(20)IX/3.1 ISM Part A-2.2 50BC
Action required: 50 - Rectify deficiencies w/in 30 days
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 4 October 2022 No resolution recorded
14501 Discharging of cargo residues that can not be recovered using commonly available methods from unloading, where all the following conditions are satisfied as per regulation 6.2.1-6.2.4. PSCO discovered that the vessel has discharged cargo hold wash within special area on multiple occasions. MARPOL Annex V REG 6.1.2 50ABC
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 October 2022 No resolution recorded
11104 Every rescue boat shall be so arranged that and adequate view forward, aft and to both sides is provided from the control and steering position for safe launching and maneuvering. PSCO observed the rescue boat with severely deteriorated windows which could not be seen out of during examination. 74SOLAS(20)II/20.2 LSA Code 5.1.1.12 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 4 October 2022 No resolution recorded
IN all ships general arrangement plans shall be permanently exhibited for the guidance of the ships officers...Serving each section. PSCO observed chemical suits and associated equipment were not stowed in appropriate location as per fire control plan. Additionally, 0 360LB bottle of nitrogen and 03 100LB bottles of propane were stored in a locker not designed to handle HAZMAT. 74SOLAS(01)II-2/20.1 15AC
Action required: 15 - Rectify deficiencies by next port
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 November 2018 Resolved
All the steering gear and components shall be of sound and reliable construction to the satisfaction of the Administration. PSCO witnessed hydraulic lock alarm sounding continuously on navigation bridge while testing emergency steering of pumps 1 and 2. Crew was unable to provide any reference attesting that alarm was working properly. SOLAS 74 2001 CONS. II-1 29.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2018
Resolved 15 November 2018
Resolution: MSU Savannah received report from Company attesting to the alarms working correctly.
Navigation › Piloting/Steering › Gyro Compass
Issued 22 December 2017 Resolved
Gyro compass was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 5 January 2018
Resolved 22 December 2017
Resolution: Letter from Electrician was sent to SSENE showing that the Gyrocompass repair had been made. Repair report has been attached.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 11 September 2016 Resolved
Each lifeboat shall be lanched and manouvered in the water at least every three months during an abandonship drill. The vessel last launched and manouvered the lifeboats on 02 April 2016
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2016
Resolution: Received class report attesting to proper abandonship drill conducted.
Engineering › Compressed Air System (control) › Valve
Issued 7 August 2015 Resolved
0999-In every ship, means shall be provided to prevent overpressure in any part of compressed air systems. The Ship's deck air receivers missing pressure relief valves to prevent over pressure. 74SOLAS(14)II-I/34.1. 50a
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 16 September 2015
Resolution: Received class report attesting to the current arrangement.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 7 August 2015 Resolved
9900-Vessel master must provide the information required by 33CFR151.2070 of this subpart in electronic or written form to the Commandant, US Coast Guard or the appropriate COTP. Vessel did not submit Ballast water reporting form to National Ballast Information Clearinghouse. 33CFR151.2060b. 10c
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 18 August 2015
Resolution: Vessel master was counseled on the correct reporting requirements listed in 33CFR151 and submitted ballast water reporting form to NBIC.
Navigation › Piloting/Steering › Gyro Compass
Issued 13 December 2010 Resolved
13DEC10 - Recieved report of vessel's gyrocompass is inop. Granted LOD to enter port. Vessel is required to make repairs prior to departure.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 December 2010
Resolved 14 December 2010
Resolution: 14Dec2010 - Contractors boarded vessel and were successful in returning gyrocompass to an operational status.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 16 January 2008 Resolved
The emergency generator was unable to be started using its secondary energy source(battery pack No. 2). The emergency generator was tested satisfactorily using the primary energy source (battery pack No. 1).
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2008
Resolved 18 January 2008
Resolution: Received class report from Lloyd’s Register satisfying requirement.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 16 November 2004 Resolved
Several lights in Foc'sl found to have exposed wires. Also several conductors leading from transformers at top of ladder vestiblue installed with exposed butt connections,(possible electrical shock hazard to ship's crew). Vessel must make permanent repoars to satisfaction of class certificate issuing authority within 30 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 December 2004
Resolved 26 December 2004
Resolution: Received class report attesting to the satisfactory repairs to the above items.

Ownership record