MAURY USCG vessel records
← All vessels

AMERICA

AMERICA is a 2004 freight ship. The Coast Guard has recorded 35 inspections since 2016, most recently in July 2026, along with 18 deficiencies and 11 operational controls.

Records from 2016 to 2026. Most recent: inspection, 22 July 2026.

Built
2004
Last inspected
22 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 July 2026
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9285990
729708
Flag
CYPRUS
Maury page id
psix-729708

Documentation record

Tonnage as PSIX records it90645 - Convention (Subpart B), Gross Ton
60740 - Convention (Subpart B), Net Ton
107749 - Dead Weight, Ton
140874 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 35

22 July 2026 PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8444362
25 December 2025 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8287218
22 July 2025 PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8191218
25 January 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8069814
20 January 2025 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8065581
17 January 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8065035
17 January 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8065346
16 January 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8064341
16 January 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8070379
13 January 2025 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8062292
9 January 2025 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8060434
7 January 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8059653
9 October 2024 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8016542
29 December 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7843262
20 July 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7747175
13 May 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7689733
28 April 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7677198
26 April 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7676280
21 July 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7512625
14 June 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7477488
13 June 2022 Ballast Water Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7469771
1 November 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7343422
27 October 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7340749
26 August 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7296909
16 March 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7156940
15 March 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7156646
10 March 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7153550
31 July 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6761344
12 July 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6467142
10 April 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6119944
8 April 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6120225
6 April 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6118780
8 February 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6084038
10 May 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5873670
4 March 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5826855

Deficiency record · 18

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 January 2025 Resolved
The arrangements for the storage, distribution, and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. PSCO observed lube oil leaks from #2 and #3 MDE lube oil coolers. 74SOLAS(09) II-2/4.2.3.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 January 2025
Resolution: Received and reviewed Class report attesting to the rectification of the leaks on the L.O. system and confirmed rectification during an in-person deficiency check.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2025 Resolved
After any survey of the ship under regulation 7,8,9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. PSCO observed lube oil system drip tray modification not approved by class. 74SOLAS(20)I/11(b) 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 January 2025
Resolution: Received and reviewed Class report attesting to the removal of the drip trays L.O. system and confirmed rectification during an in-person deficiency check.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2025 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed minor air and water leak from pressure reducing valve between main air bottles and M/E. 74SOLAS(04)II-1/26.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 January 2025
Resolution: Received and reviewed Class report attesting to the rectification of the air/water leak and confirmed rectification during an in-person deficiency check. Ball valve was renewed and air reducitng valves were re-tightened.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 20 January 2025 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed significant water leak from flange below boiler soot collection tank drain pipe. 74SOLAS(04)II-1/26.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 January 2025
Resolution: Received and reviewed Class report attesting to the rectification of the leaks on the drain pipe below boiler soot collection tank and confirmed rectification during an in-person deficiency check. The system was not in operation at the time of exam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 January 2025 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed exposed wiring inside #3 diesel generator cover near the #1 cylinder. 74SOLAS(04)II-1/40.1.3 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 January 2025
Resolution: Received and reviewed Class report attesting to the rectification of the exposed electrical wiring and confirmed rectification during an in-person deficiency check. Junction box was properly covered.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 January 2025 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed load line lacking paint. 66 ICLL (prot 88) Reg.8 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 January 2025
Resolution: Received and reviewed Class report attesting to the rectification of the LL being painted and confirmed rectification during an in-person deficiency check.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2025 Resolved
The machinery associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed soft patch on the #1 main engine cooling pump suction, which was isolated by a valve.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2025
Resolution: Vessel was given a condition of class for permanent repairs to be done NLT 16FEB2025. However, on 1/17, PSCO verified that spool piece had been renewed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 January 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed evidence of oil leak in small discharge containment (drip tray) from auxiliary engines. 74 SOLAS (04) II-2/4.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 January 2025
Resolution: Received Class report attesting to the repairs and clean up of excessive oils. See Class report for further details.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 January 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed collection of hydraulic oil in the steering gear room, diesel under the purifier, and oil under the #1 main engine lube oil cooler. 74 SOLAS (04) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 January 2025
Resolution: Crew corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 January 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed excessive oil accumulation at #1, 2 and 3 A/E. PSCO observed oil accumulation in the purifier room around the D.O. SERV. TANK(P), and the NO.2 M/E F.O. CIRC. PUMP. 74SOLAS(04) II-2/4.1.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2025
Resolution: Recieved remote class report attesting to repairs. See attachments
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 9 January 2025 Resolved
External high pressure fuel delivery lines shall be protected and capable of containing fuel from a high pressure line failure. PSCO observed a leak on the high pressure fuel line on the #12 cylinder on M/E. 74SOLAS(04) II-2/4.2.2.5.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2025
Resolution: Recieved separate class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 January 2025 Resolved
Suitable oil collection arrangements for leaks shall comply with 2.2.5.1. PSCO observed unapproved catch basins and hoses in the furifier room and A/E's. 74SOLAS(04) II-2/2.2.4 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2025
Resolution: Recieved class report attesting to repairs
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 9 January 2025 Resolved
The Oil Record Book... shall be in the form specified in appendix III to this annex. In the Oil Record Book, the entry dated 27DEC24 noted 29.6 m3 was discharged through the oily water separator in two hours - which exceeds the OWS's capacity of 10m3. The error was not identified or logged correctly. MARPOL I/17.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 January 2025
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 April 2023 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed numerous kinked flexible hoses between CO2 bottles and CO2 header.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2023
Resolved 15 July 2023
Resolution: RO (LR) report received. RO attended on 12 MAY 23 in Houston TX.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 13 June 2022 Resolved
Before the ship leaves port and at all time during the voyage, all life-saving appilances shall be in working order and ready for immediate use. Port side rescue/lifeboat rudder was seized and could not move using steering wheel. 74SOLAS (2020 Cons) III.20.2 17ac=> 10c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2022
Resolution: Crew repaired broken O-ring on steering column prior to USCG inspectors departing. Witnessed SAT operation of steering wheel moving the rudder with no issue. Cleared on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 June 2022 Resolved
Guard rails or bulwarks shall be fitted around the exposed decks. PSCO's observed various signs of wastage on the guard rails on both port and starboard side of the cargo deck. ICLL (88 Prot.) Reg. 25 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2022
Resolved 21 July 2022
Resolution: Vessel provided class report attesting to the rectification of the wasted areas on guardrails on the port and starboard cargo deck area.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 13 June 2022 Resolved
The links, rings and letters shall be printed in white or yellow on a dark gound or black on a light ground. Starboard side load line is not currently painted in contrasting color; paint wasted off. ICLL (88 Prot.) Reg 8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2022
Resolved 21 July 2022
Resolution: Vessel provided class report attesting to the proper painting of the loadline marking on the starboard side.
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 May 2016 Resolved
1530-Radar-Each vessel of 10000 GT or more must have a second marine radar system that operates independently of the first. The vessel reports that its S-Band Radar ins inoperative.-33CFR164.37
Action required: 705 - Other - as specified
Resolved 13 May 2016
Resolution: Vessel submitted a technician's report indicating successful repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.