MAURY USCG vessel records Sign in
← All vessels

JASMINE EXPRESS

JASMINE EXPRESS is a 2003 tank ship. The Coast Guard has recorded 32 inspections since 2004, most recently in March 2020, along with 7 deficiencies and 3 operational controls.

Records from 2004 to 2020. Most recent: inspection, 25 March 2020.

Built
2003
Last inspected
25 March 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9288370 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
729756
Flag
HONG KONG
—
Maury page id
psix-729756

Inspections, by type

…with no type recorded12
Years with a record 10 calendar years (2004–2020)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it26909 - Regulatory (Subpart C or D), Gross Ton
13486 - Regulatory (Subpart C or D), Net Ton
55855 - Displacement, Ton
46999 - Dead Weight, Ton
26909 - Convention (Subpart B), Gross Ton
13486 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

25 March 2020 COC-TVE Renew
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6928668
11 March 2016 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5826584
28 March 2014 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4824945
11 March 2014 ISPS II Exam · COC-TVE Renew
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4813830
3 September 2010 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3852025
27 March 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam · ILO-147 Exam · STCW 95 Exam · COC-TVE Renew · MARPOL Annex VI Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3703562
20 February 2009 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3424961
6 November 2008 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3358166
27 August 2008 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3310141
25 April 2008 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3191913
21 April 2008 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3188624
17 April 2008 COC-TVE Annual · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3186369
26 February 2008 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3152975
13 December 2007 ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3114724
20 November 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3101601
30 July 2007 NPV Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3012567
30 July 2007 Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 3015730
27 July 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3009512
10 May 2007 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2926869
17 April 2007 COC-TVE Annual
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2909513
8 February 2006 ISPS III Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2581063
5 February 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2580612
1 February 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2577784
31 July 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2446287
15 July 2005 Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2428341
15 July 2005 MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2430681
11 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2422538
1 July 2005 In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2408865
2 June 2005 PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2376562
28 December 2004 ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2265446
23 November 2004 COC-TVE Renew
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2246687
21 November 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2245269

Deficiency record · 7

Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 11 March 2016 Resolved
The venting system shall be provided with devices to prevent the passage of flame into the cargo tanks. A cargo tank flame screen was missing and a reserve oil tank flame screen was wasted. 74SOLAS(04) Ch II-2 REG 4.5.3.3
Condition: Improper/Lack of Maintenance
Due 11 March 2016
Resolved 11 March 2016
Resolution: crew members replaced flame screens on the spot.
Electrical › Electric Generation Source (emergency) › Generator
Issued 17 April 2008 Resolved
Noted that the spare parts required in internal audit dated 15-March-08 were not on board. Vessel is required to submit a receipt of Emergency SSDG parts to RIO St. Croix within 7 days. Deficiency will be cleared to the satisfcation of RIO St. Croix.
Due 26 April 2008
Resolved 25 April 2008
Resolution: Rcvd Masters statement affirming receipt of spare starter for EDG. Cleared def.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 July 2007 Resolved
Vessel's Master and Chief Mate indicated vessel is not in practice of checking oxygen(O2) levels of cargo tanks each day in accordance with vessel's Safety Management System (SMS) Cargo Operation Manual, page 22-23 of Rev. 3 dated 15SEP06.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2007
Resolved 1 August 2007
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 30 July 2007 Resolved
Vessel was found with O2 levels exceeding 11% in cargo tanks. SOLAS (2001) Ch II-2 Reg 62 To the satisfaction of the Coast Guard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2007
Resolved 30 July 2007
Resolution: Cargo tanks below 8% O2.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 17 April 2007 Resolved
emergency lighting at 6 man life raft bow station inoperative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 17 April 2007
Resolution: repaired lighting, ops normal.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 17 April 2007 Resolved
3 small cracks were found on the door of the incinerator. 70a
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 10 May 2007
Resolution: Received class report, record # 07NG0499, stating: The damaged part has been repaired by crewmembers on 23APR07. Attending class surveyor found the repairs to be satisfactory.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 28 December 2004 Resolved
The Advance Notice of Arrival did not give the proper list of the last five ports.
Action required: 705 - Other - as specified
Due 28 December 2004
Resolved 28 December 2004
Resolution: Master has been instructed on the importance of listing all ports on the ANOA.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.