Records from 2004 to 2008. Most recent: operational control imposed, 7 November 2008.
Inspection history · 20
7 November 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3359261
6 November 2008
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3359039
2 September 2008
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3316669
2 September 2008
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3316774
11 May 2007
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2925819
31 January 2007
PII Safety Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2864503
20 July 2006
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2719181
26 February 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2592076
26 February 2006
ISPS III Exam · NPV Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2592134
15 February 2006
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2585421
15 February 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2585940
19 October 2005
Random ISPS/MTSA/PSC
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2517787
11 October 2005
Spot Check · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2511877
11 August 2005
ISPS II Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2458980
20 June 2005
ISPS II Exam · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2396150
23 May 2005
Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2365780
25 April 2005
Ballast Water Examination · MARPOL Annex I Examination · NPV Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2341506
6 December 2004
NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2253525
22 November 2004
PI Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2246203
22 November 2004
ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2246209
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 2 September 2008
No resolution recorded
Vessel unable to show proper operation of ship's incinerator due to equipment malfunction. Class surveyor to attest to proper operation of system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Steam System (auxiliary) › Valve
Issued 2 September 2008
Resolved
Steam leak discovered on auxiliary boiler valve posing a hazard to personnel. Class surveyor to attest to proper operation of system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 November 2008
Resolution: Steam leak repaired to attending Coast Guard Marine Inspector satisfaction.
Fire Fighting › Combustible Materials › Insulation
Issued 2 September 2008
Resolved
Excessive flammable material found on top of auxiliary boiler poses ignition fire hazard in engine room.
Action required: 705 - Other - as specified
Resolved 2 September 2008
Resolution: Material removed to satisfaction of Coast Guard Inspectors.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 September 2008
Resolved
Guards not in place around auxiliary boiler flanges to protect personnel from hot surfaces.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 November 2008
Resolution: Guards installed around boiler flanges to Coast Guard Marine Inspector satisfaction.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 September 2008
Resolved
Guards not in place around Number 1 fire pump to protect personnel from rotating machinery.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 November 2008
Resolution: Guards installed around nr 1 fire pump to Coast Guard Marine Inspector satisfaction.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 September 2008
Resolved
Guards not in place around Number 2 fire pump to protect personnel from rotating machinery.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 November 2008
Resolution: Guards installed around nr 2 fire pump to Coast Guard Marine Inspector satisfaction.
Accommodation/Occupational Safety › Ventilation › General
Issued 2 September 2008
No resolution recorded
Accomodations space ventilation system failed to adequately maintain proper environmental conditions due to inoperable air conditioning system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Electric Generation Source (service) › Generator
Issued 2 September 2008
Resolved
Number 2 ship's service generator found leaking raw water from cooling system. Class surveyor to attest to proper functioning of generator prior to vessel's departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2008
Resolution: Class surveyor submitted report attesting to proper operation of no.2 ship''s service generator. Water leak on cylinder head to be permanently repaired by 02OCT08. Class surveyor report attached as vessel document.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 2 September 2008
Resolved
Fire door in machinery space emergency escape held open with ties allowing passage of smoke and flame.
Action required: 705 - Other - as specified
Resolved 2 September 2008
Resolution: Fire door ties removed to the satisfaction of Coast Guard inspectors.
Electrical › Electric Generation Source (service) › Generator
Issued 11 May 2007
No resolution recorded
Number 2 ship service generator has a pin-hole, cooling water leak. Signs show that the leak has been there for a few months.
Action required: 705 - Other - as specified
Due 25 May 2007 — due date passed with no resolution recorded
Fire Fighting › Fire Hoses › Condition
Issued 31 January 2007
Resolved
01 Fire hose in the engine room was holed.
Action required: 705 - Other - as specified
Resolved 31 January 2007
Resolution: Holed fire hose was replaced with a new hose on the spot.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 31 January 2007
Resolved
The OWS was found to be inop. The OWS could not operate without alarming. Prove that OWS is operating properly and operate for 20 min with out alarm sounding. Prove that the shut off (recirculating) valve to the overboard discharge from the OWS is working properly.
Action required: 705 - Other - as specified
Due 1 February 2007
Resolved 1 February 2007
Resolution: The OWS was found to be operating properly. OWS ran for 20 min without alarming. Tested shut off valve to overboard discharge. Valve worked properly.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 31 January 2007
Resolved
The general house keeping of the engine room is poor. Ther is excess oil and debris through out the engine room.
Action required: 705 - Other - as specified
Due 1 February 2007
Resolved 1 February 2007
Resolution: The engine room has been cleaned and all house keeping issues have been addressed.
Fire Fighting › Means of Escape › Blocked
Issued 31 January 2007
Resolved
The emergency escape in the engine room was blocked by gear that was inproperly stored.
Action required: 705 - Other - as specified
Resolved 31 January 2007
Resolution: Gear was moved and emergency exit is clear.
Fire Fighting › Means of Escape › Blocked
Issued 31 January 2007
Resolved
The emergency escape in the control room is blocked with gear that was not stored properly.
Action required: 705 - Other - as specified
Due 1 February 2007
Resolved 1 February 2007
Resolution: The emergency exit in the control room has been cleared of any obstructions.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 October 2005
Resolved
LACK OF GRATINGS OR NON SLIP SURFACE AROUND STEERING GEAR TO ENSURE SUITABLE WORKING CONDITIONS IN THE EVENT OF LEAKAGE
Action required: 705 - Other - as specified
Due 19 November 2005
Resolved 17 February 2006
Resolution: Coast Guard inspected the steering gear compartment and found proper hand railing and non-slip flooring.
Fire Fighting › Self-contained Breathing Apparatus › Quantity
Issued 19 October 2005
Resolved
HAVE CLASS ATTEST TO PROPER AMOUNT OF EEBD'S REQUIRED ONBOARD AND LOCATIONS. SAFETY EQUIMPMENT STATES 5 REQUIRED, FIRE CONTROL PLAN STATES 8, BUT ONLY DISPLAYS 7
Action required: 705 - Other - as specified
Due 19 November 2005
Resolved 17 February 2006
Resolution: Recived fax from class attesting to the proper amount of EEBD ob board.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 25 April 2005
Resolved
Vessel has minor cracks in bulwark framing on port and starboard side by the way of number 2 cargo hold frames 118 and 120.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 23 May 2005
Resolution: Received class report from BV satisfying the requirement.