RAVNANGER

RAVNANGER is a 2000 tank ship. The Coast Guard has recorded 25 inspections since 2000, most recently in May 2014, along with 5 deficiencies — 1 with no resolution recorded — and 5 operational controls.

Records from 2000 to 2014. Most recent: inspection, 30 May 2014.

Built
2000
Last inspected
30 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9212371 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
NORWAY
—
Maury page id
psix-7300

Inspections, by type

…with no type recorded9
…past their stated due date1
Years with a record 12 calendar years (2000–2014)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it46337 - Dead Weight, Ton
56091 - Displacement, Ton
28278 - Convention (Subpart B), Gross Ton
12481 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

30 May 2014 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4871245
31 January 2012 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4231361
4 July 2011 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4066949
22 February 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3682524
19 February 2010 ISPS I Exam · COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3682547
11 January 2010 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3662275
23 October 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3350119
29 June 2008 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual · MARPOL Annex II Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3248851
5 November 2007 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3097642
17 October 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3081810
16 May 2007 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam · MARPOL Annex II Examination · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2931889
31 July 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2731918
21 June 2006 MARPOL Annex V Examination · ISPS III Exam · COC-CHEM Renew · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2686765
4 May 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2640867
19 October 2005 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2516445
19 November 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2244365
18 July 2004 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2136010
29 May 2002 Certificate of Compliance
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1622653
28 April 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1634029
18 March 2002 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1494517
14 June 2001 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 290926
14 June 2001 Tank Vessel Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1067944
17 January 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 448817
23 June 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 279345
23 June 2000 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1426425

Deficiency record · 5

Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 11 January 2010 Resolved
Vessel's MSD was found with evidence of substantial pitting and the use of putty for a temporary repair. In addition, evidence of welding patches for other repairs were found by PSC Officers. Vessels was unable to provide documentation attesting to administration approval of repairs made. SOLAS 74/88 2004 Consolidated Chapter 1, Reg. 11
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 January 2010
Resolved 5 April 2010
Resolution: Received DNV class report carried out at Santo Domingo/Rio haina on 2010-02-10 from surveyor [name withheld] testifying to the satisfactory repair of the MSD.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 11 January 2010 No resolution recorded
Crew was using improper procedures to verify IGG (O2) analyzers calibration. Vessel previously depleted a mixed span gas cylinder and replaced it with N2. N2 cylinder has no calibration certificate. Vessel was using mixed gas procedures instead of N2 procedures after change-out occurred. FSS Code Chapter 15 2.4.2.5
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 January 2010 — due date passed with no resolution recorded
Resolution: Received class report completed at Houston, TX on 2010-01-11 by Yu, Hao Bing. The report stated that "new N2 span gas was supplied and certificate was reviewed and found in order. The calibration test was carried out in the presence of surveyor."
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 October 2008 Resolved
Received a letter of deviation from the vessel for the secondary marine radar.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2008
Resolution: Received a technician''s report attesting to the repairs made to the secondary marine radar that concluded the secondary marine radar is nominal.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 May 2007 Resolved
Soft patch made of metallic band and rubber gasket on sea water cooling system pipe in engine room. Repair to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 22 May 2007
Resolution: sea water cooling system pipe temporarily repaired to the satisfaction of class. Cement box constructed around pipe to prevent leak
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 21 June 2006 Resolved
Ships port anchor chain has loose divider in ninth link back from swivel. Several of the other chain links have welds connecting the divider to the chain links have failed. have attending classification society inspect and submit report to coast guard of intended repairs. Have STBD side chain also inspected.
Action required: 705 - Other - as specified
Due 21 July 2006
Resolved 11 July 2006
Resolution: Received ABS Class report No. R0728038 stating repairs completed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.