← All vessels
RAVNANGER
RAVNANGER is a 2000 tank ship. The Coast Guard has recorded 25 inspections since 2000, most recently in May 2014, along with 5 deficiencies — 1 with no resolution recorded — and 5 operational controls.
Records from 2000 to 2014. Most recent: inspection, 30 May 2014.
- Built
- 2000
- Last inspected
- 30 May 2014
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9212371 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LAKP6
7300
Flag
NORWAY
—
Maury page id
psix-7300
Inspections, by type
…with no type recorded9
…past their stated due date1
Years with a record
12 calendar years (2000–2014)
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it46337 - Dead Weight, Ton
56091 - Displacement, Ton
28278 - Convention (Subpart B), Gross Ton
12481 - Convention (Subpart B), Net Ton
56091 - Displacement, Ton
28278 - Convention (Subpart B), Gross Ton
12481 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 25
30 May 2014
COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4871245
31 January 2012
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4231361
4 July 2011
COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4066949
22 February 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3682524
19 February 2010
ISPS I Exam · COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3682547
11 January 2010
Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3662275
23 October 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3350119
29 June 2008
Ballast Water Examination · ISPS II Exam · COC-CHEM Annual · MARPOL Annex II Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3248851
5 November 2007
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3097642
17 October 2007
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3081810
16 May 2007
Ballast Water Examination · COC-CHEM Renew · ISPS II Exam · MARPOL Annex II Examination · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2931889
31 July 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2731918
21 June 2006
MARPOL Annex V Examination · ISPS III Exam · COC-CHEM Renew · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2686765
4 May 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2640867
19 October 2005
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2516445
19 November 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2244365
18 July 2004
Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2136010
29 May 2002
Certificate of Compliance
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1622653
28 April 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1634029
18 March 2002
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1494517
14 June 2001
Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 290926
14 June 2001
Tank Vessel Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1067944
17 January 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 448817
23 June 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 279345
23 June 2000
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1426425
Deficiency record · 5
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 11 January 2010
Resolved
Vessel's MSD was found with evidence of substantial pitting and the use of putty for a temporary repair. In addition, evidence of welding patches for other repairs were found by PSC Officers. Vessels was unable to provide documentation attesting to administration approval of repairs made. SOLAS 74/88 2004 Consolidated Chapter 1, Reg. 11
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 11 January 2010
No resolution recorded
Crew was using improper procedures to verify IGG (O2) analyzers calibration. Vessel previously depleted a mixed span gas cylinder and replaced it with N2. N2 cylinder has no calibration certificate. Vessel was using mixed gas procedures instead of N2 procedures after change-out occurred. FSS Code Chapter 15 2.4.2.5
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 October 2008
Resolved
Received a letter of deviation from the vessel for the secondary marine radar.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 May 2007
Resolved
Soft patch made of metallic band and rubber gasket on sea water cooling system pipe in engine room. Repair to the satisfaction of Class.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 21 June 2006
Resolved
Ships port anchor chain has loose divider in ninth link back from swivel. Several of the other chain links have welds connecting the divider to the chain links have failed. have attending classification society inspect and submit report to coast guard of intended repairs. Have STBD side chain also inspected.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.