← All vessels
DIAMOND LAND
DIAMOND LAND is a 2004 freight ship. The Coast Guard has recorded 58 inspections since 2004, most recently in October 2022, along with 25 deficiencies and 18 operational controls.
Records from 2004 to 2022. Most recent: inspection, 18 October 2022.
- Built
- 2004
- Last inspected
- 18 October 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9262560 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7AZ843
730305
Flag
MARSHALL ISLANDS
—
Maury page id
psix-730305
Inspections, by type
…with no type recorded19
Years with a record
16 calendar years (2004–2022)
The 58 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it24918 - Convention (Subpart B), Gross Ton
12540 - Convention (Subpart B), Net Ton
35040 - Dead Weight, Metric Ton
46327 - Displacement, Metric Ton
12540 - Convention (Subpart B), Net Ton
35040 - Dead Weight, Metric Ton
46327 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 58
18 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579573
28 December 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7372984
3 September 2021
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7303404
27 August 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7298490
12 August 2021
Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7284916
10 August 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7282976
3 August 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7275931
14 May 2021
Appeal
Administrative · Commandant (CG-CVC) · Activity 7200510
7 May 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7191589
18 April 2021
Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7177359
13 April 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7174271
12 April 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7173293
8 April 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7171166
2 April 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7167446
13 December 2020
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7111008
11 September 2020
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7057725
10 August 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7028748
12 April 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6938417
11 April 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6938273
8 January 2020
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6884946
10 December 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6871223
8 December 2019
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6865013
8 December 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6869379
29 April 2019
PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6672432
6 December 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6593059
4 December 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6591696
4 December 2018
Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6592101
24 August 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6521820
6 August 2018
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6502268
24 July 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6489095
29 April 2018
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6400632
17 April 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6393049
11 April 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6389405
25 April 2017
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6132832
4 April 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6113124
15 January 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6071147
20 December 2016
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6058357
7 December 2016
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6049831
11 August 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5970677
6 August 2016
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5963818
8 July 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5934357
3 July 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5927412
3 July 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5928029
28 June 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5922652
8 May 2012
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4296135
18 February 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3943108
12 January 2010
Ballast Water Examination · ISPS II Exam · MARPOL Annex VI Survey · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3658509
3 January 2009
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3388058
30 December 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3386315
26 December 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3385028
4 September 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3048240
6 April 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2613794
25 March 2005
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2319340
17 March 2005
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2312467
17 March 2005
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2313399
29 November 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2249440
27 November 2004
ISPS I Exam · PI Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2250281
26 November 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2249448
Deficiency record · 25
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 December 2019
Resolved
07113- Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO was notified by captain that priming system for the emergency fire pump in inoperable and pump is incapable of being primed under high ballast conditions. SOLAS 74 (a) 2014 (cons) II-2/14.2.1.2 60ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018
Resolved
13199- MACHINERY(OTHER)- AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8,9, OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGMENTS, MACHINERY EQUIPMENT, AND OTHER ITEMS COVERED BY THE SURVEY WITHOUT THE SSANCTION OF THE ADMINISTRATION. 03 FUEL PUMP SIGHT GLASSSES HAVE BEEN MODIFIED BY ALTERNATE MEANS OF ORIGINAL DESIGN. ALL SIGHT GLASSES WERE ONSERVED TO HAVE HOLES, NO VISIBILITY, AND OIL MIST COMING FROM THE HOLES. SOLAS 74 (2004) CH I/11(B)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 August 2018
Resolved
02105-Steering gear-The main steering gear and rudder stock shall be: capable of putting the rudder over from 35 deg on one side to 35 deg on the other side with the ship at its deepest seagoing draught and running ahead at maximum ahead service speed and, under the same conditions, from 35 deg on either side to 30 deg on the other side in not more than 28s. During operational test, #2 emergencysteering gear could not achieve 35 to 35 deg operation. SOLAS 74 a (2004 Cons) II-1/29.3.2 30a
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 August 2018
Resolved
02105-Steering Gear-A low-level alarm for each hydraulic fluid resicour to give the earliest practical indication of hydraulic fluid leakage. audible and visual alarms shall be given on the navigation bridge and machinery space where they can be readily observed. PSCO observed #1 and #2 Steering gear tank low level alarms inoperable. SOLAS 74 a (2004 Cons) II-1/29.12.2 60a
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2018
Resolved
13199-Other (machinery)- The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and ,protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed oil leaks IWO MDE turbo, and SSG # 3 turbo. Additionally, MDE turbo bearing oil condition indicates a seal leak.
SOLAS 74 a (2004 Cons) II-I/47.2 60a
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 August 2018
Resolved
13101-Propulsion main engine- Internal combustion engines of 2,250 kW and above or having cylinders of more than 300 mm bore shall be provided with crankcase oil mist detectors or engine baring temperature monitors or equivalent devices. PSCO observed flow fault on MDE oil mist detector, crew reset and alarm returned in approximatly 20 minutes. SOLAS 74 a (2004 Cons) II-I/47.2 60(a)
Fire Fighting › Fire Pumps › Pressure
Issued 12 April 2018
Resolved
0740-PUMPS-EMERGENCY FIRE PUMPS PRESSURE SHALL NOT BE LESS THAN THE MINIMUM PRESSURE GIVEN IN PARAGRAPH 4.2. TWO FIRE HOSES WERE TESTED FOR A MINIMUM OF 5 MINUTES IN WHICH THE PRESSURE WAS OBSERVED AT 0.20 N/MM2 FROM THE START AND CONTINUED TO DROP TO 0.17 N/MM2, NEVER MEETING THE MINIMUM PRESSURE REQUIREMENT OF 0.27N/MM2.
74 SOLAS (2001) II-2/4.3.3.2.2
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 April 2018
Resolved
1685-OPERATION/MAINTENANCE-THE ADMINISTRATION SHALL ENSURE THAT RADIO EQUIPMENT REQUIRED BY THIS CHAPTER IS MAINTAINED TO PROVIDE THE AVAILABILITY OF THE FUNCTIONAL REQUIREMENTS SPECIFIED IN REGULATION 4, TO MEET THE RECOMMENDED PERFORMANCE STANDARDS OF SUCH EQUIPMENT. GMDSS DID NOT HAVE SATELLITE CONNECTION, RENDERING REQUIRED EQUIPMENT UNABLE TO RECEIVE OR TRANSMIT DISTRESS ALERTS, COMMUNICATIONS OR SIGNALS.
74 SOLAS (2004)IV/15.5
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 12 April 2018
Resolved
2010-MUSTER LIST-CLEAR INSTRUCTIONS TO BE FOLLOWED IN THE EVENT OF AN EMERGENCY SHALL BE PROVIDED FOR EVERY PERSON ON BOARD. SHIP'S FIRE BILL ACKNOWLEDGING CREW RESPONSIBILITIES ON SHIPBOARD FIRE PROCEDURES DID NOT REFLECT THE CURRENT CREW ON BOARD; MASTER AND CHIEF ENGINEER WERE NOT LISTED.
74 SOLAS (2014) III/8.2
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 April 2018
Resolved
0820-PROTECTION MACHINES/PARTS-THE MACHINERY SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. THE COVER FOR THE SEA CHEST PUMP WAS REMOVED, FULLY EXPOSING ALL MOVING PARTS, POSING A SAFETY HAZARD TO THE CREW.
74 SOLAS (2001 )II-2/26.1
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 12 April 2018
Resolved
0720-FIRE FIGHTING EQUIPMENT-FIRE EXTINGUISHERS SHALL BE PERIODICALLY EXAMINED. NUMEROUS FIRE EXTINGUISHERS ON MULTIPLE DECKS HAD NOT BEEN EXAMINED IN OVER 30 DAYS WHEN NORMAL SHIP PROCEDURE IS TO INSPECT FIRE EXTINGUISHERS MONTHLY.
74 SOLAS (2001) II-2/6.5
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 April 2018
Resolved
0899-OTHER (ACCIDENT. PREVENTION.)-THE OPENINGS BELOW THE LOWEST COURSE OF THE GUARD RAILS SHALL NOT EXCEED 230 MM (9 INCHES). PSCO OBSERVED 04 GUARD RAILS ON MAIN DECK OF WHICH WERE BROKEN OR MISSING.
ICLL66, REG.25 (3)
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 April 2018
Resolved
1430-AUXILIARY ENGINES-THE ELECTRICAL POWER AVAILABLE SHALL BE SUFFICIENT TO SUPPLY ALL THOSE SERVICES THAT ARE ESSENTIAL FOR SAFETY IN AN EMERGENCY. PSCOs OBSERVED THE EMERGENCY GENERATOR WAS NOT SUPPLIED WITH ENOUGH FUEL TO SUPPLY ALL SERVICES THAT ARE ESSENTIAL FOR SAFETY IN AN EMERGENCY. CREW HAD REMOVED REQUIRED FUEL FROM THE EMERGENCY GENERATOR TO PREVENT THE OVERFILL ALARM FROM ALERTING BECAUSE THE ALARM BECAME A NUISANCE TO THE CREW.
74 SOLAS (2004) II-1/43.2
Fire Fighting › Ventilation Systems › Smoke Extraction System
Issued 12 April 2018
Resolved
0715-DETECTION-SUITABLE INSTRUCTIONS SHALL BE PROVIDED FOR THE TESTING AND MAINTENANCE OF THE SYSTEM. PSCOs DISCOVERED A SMOKE EXTRACTION SUCTION FAILURE ALARM IN CARGO HOLD NO. 01; UPON FURTHER INQUIRY, THE SYSTEM FAILURE ORIGINALLY OCCURRED IN FEBRUARY TOTALING 56 FAULT CODES UPON PSC EXAM THAT WERE NOT ADDRESSED BY THE CREW. UPON QUESTIONING [name withheld] ENGINEER, THE [name withheld] THAT THE [name withheld] INSPECTIONS; HOWEVER, NO INFORMATION WAS AVAILABLE TO DECIPHER THE CODES REFERENCING THE FAULTS. CREW WERE UNFAMILIAR WITH THE SYSTEM.
74 SOLAS (2001 )II-2/13.1.1.9
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 12 April 2018
Resolved
2545-REPORTS/ANALYSIS OF NON-CONFORMITIES ETC.)-THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. BASED ON THE ABOVE NOTED DEFICIENCIES, PSCO OBSERVED SUBSTANDARD COMPLIANCE AND INADEQUATE ATTENTION TO FIRE SAFETY SYSTEMS, CREW SAFETY, AND PERIODICAL MAINTENANCE SYSTEM INSPECTIONS.
74 SOLAS (2014)IX/3.1 REF ISM CODE 10.1
Lifesaving › Lifeboat Equipment › Food Ration
Issued 12 April 2018
Resolved
0610-LIFEBOATS-NORMAL EQUIPMENT OF EVERY LIFEBOAT SHALL CONSIST OF A FOOD RATION NOT TOTALING LESS THAN 10,000KJ FOR EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCOMMODATE. FREE-FALL LIFEBOAT REQUIRING 29 FOOD RATIONS (AS PER THE SAFETY EQUIPMENT CERTIFICATE FORM E) WAS FOUND WITH 06 UNSATISFACTORY RATIONS, WITH NO SPARES ON BOARD.
74 SOLAS (2014)III/34 REF LSA CODE 4.4.8.12
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 April 2018
Resolved
1420- CLEANLINESS OF ENGINE ROOM - IN A SHIP IN WHICH OIL IS USED THE ARRANGEMENTS FOR THE STORAGE DISTRIBUTION AND UTILIZATION OF THE FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCOs DISCOVERED NUMEROUS AREAS IN THE ENGINE ROOM WHERE FUEL OIL WAS ALLOWED TO POOL. OIL SOAKED RAGS WERE LEFT PROMINENTLY THROUGHOUT THE ENGINE ROOM. THE MOST NOTABLE LOCATIONS ARE THE MAIN ENGINE IN THE VICINITY OF THE FUEL PUMPS, BETWEEN CRANKCASE AND TURBO CHARGER, SHAFT-ALLEY, AND UNDER SHIP SERVICE DIESEL GENERATORS, CREATING A SUBSTANTIAL FIRE HAZARD.
74 SOLAS (2001) II-2/15.2
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 April 2018
Resolved
09100 - CLOSING DEVICES WATERTIGHT DOORS - STRUCTURAL FIRE PROTECTION INCLUDING FIRE RESISTING DIVISIONS, PROTECTION OF OPENINGS, AND PENETRATIONS IN THESE DIVISIONS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS. A-CLASS BOUNDARY DOORS FOR THE MAIN STAIRWAY, ENGINE CONTROL ROOM, AND GALLEY DID NOT SELF CLOSE DUE TO FAULTY DOOR LATCHES, HINGES TO INCLUDE WASTED AND MISSING DOOR SEALS.
74 SOLAS (2014) II-2/14.2.1.1.1
Engineering › Fuel Oil Service System › Filter
Issued 20 December 2016
Resolved
1499-Connections with in the fuel supply and spill lines shall be constructed having regards to their ability to prevent pressurized oil fuel leaks while in servie and after maintemance. PSCO observed a steady fuel drip on #2 generator at the fuel filter at approx. 100 drips per minute. SOLAS 74a (09 consolidated) II-2/4.2.2.5.4, 17a
Engineering › Steering Gear System › Power Unit
Issued 20 December 2016
Resolved
1099-Means for indicationg that the motor of electric and electric-hydraulic steering gear are running shall be installed on the navigation bridge and a suitable main machinary control position. PSCO observed the power supply and running lights were out at the control panel for the # 1 steering gear controller in the steering compartment. SOLAS 74a (09 consolidated) II-1/30.1, 16a
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 20 December 2016
Resolved
0199-Each loading arm and each transfer piupe system, including non metallic hoses must not leack under static liquid pressure at least 1 1/2 times MAWP. Vessel could not provide documentation of currant hydrostatic test. 33 CFR 156.170 (c)
Lifesaving › Lifeboat › Propulsion Engine
Issued 7 December 2016
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and available for immediate use. Currently, the engine on the vessels free fall lifeboat will not start.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 7 December 2016
Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all time. PSCO examined the fixed fire detection and fire alarm system in the main propulsion machinery space and discovered it was not operational, due to the crew disabling the system.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 7 December 2016
Resolved
The Company should ensure that the policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. Examiners identified the following items not maintained in accordance with the policy: SMS procedures not being followed (see narrative & scanned Form B for detailed information).
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 July 2016
Resolved
OIL FILTERING EQUIP DISCHARGE MOTOR/PUMP NOT OPERATIONAL RENDERING SYSTEM UNFUNCTIONAL FOR INTENDED PURPOSES.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National