MAURY USCG vessel records Sign in
← All vessels

TIP STOCKHOLM

TIP STOCKHOLM is a 2004 freight ship. The Coast Guard has recorded 43 inspections since 2004, most recently in July 2018, along with 9 deficiencies and 13 operational controls.

Records from 2004 to 2018. Most recent: inspection, 30 July 2018.

Built
2004
Last inspected
30 July 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9277333 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA3942
730403
Flag
MALTA
—
Maury page id
psix-730403

Inspections, by type

…with no type recorded17
Years with a record 10 calendar years (2004–2018)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5057 - Convention (Subpart B), Gross Ton
2681 - Convention (Subpart B), Net Ton
5057 - Regulatory (Subpart C or D), Gross Ton
2681 - Regulatory (Subpart C or D), Net Ton
10379 - Displacement, Metric Ton
77449 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 43

30 July 2018 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6495235
26 July 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6491580
26 July 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6491637
28 May 2018 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6426681
23 May 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6421804
19 April 2018 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6395110
26 March 2018 PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6378548
24 March 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6375043
24 March 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6375099
17 February 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6353774
17 February 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6358027
23 December 2017 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6329365
18 December 2017 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6340286
16 October 2017 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6289714
12 September 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6265060
8 May 2017 ISPS III Exam · COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6141176
15 April 2017 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6124857
4 March 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6098845
11 February 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6083010
20 September 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4147057
14 December 2010 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3909511
20 October 2010 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3867811
23 March 2010 ISPS I Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3701392
22 March 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3697344
22 March 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3700947
3 April 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3445617
3 April 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3445662
3 April 2009 ISPS I Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3445763
17 August 2008 Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3295445
16 August 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3295452
17 October 2007 MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3081786
3 October 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3072327
12 July 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2992581
15 September 2006 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2779321
21 June 2006 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2687251
26 March 2006 ISPS I Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2610892
6 January 2006 ISPS I Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2562347
12 October 2005 ISPS I Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2512517
5 October 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2508483
25 May 2005 MARPOL Annex V Examination · ISPS II Exam · NPV Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2367155
24 February 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2298466
25 November 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2249703
24 November 2004 ISPS II Exam · Ballast Water Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2247629

Deficiency record · 9

Engineering › Bilge Water Management System › Not Operational
Issued 22 February 2018 Resolved
Code 1099: The condition of the ship and its equipment shall be maintained to conform with the provisions of he present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel's water ingress alarm located in cargo holds is not working. 74SOLAS (2014) CH I/Reg 11.a (17c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2018
Resolution: PSCE's verified operational test of Cargo Hold water ingress alarms
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 18 February 2018 Resolved
0135- For every ship to which Chapter 1 applies, the Administration shall: issue an appropriate minimum safe manning document or equivalent as evidence of the minimum safe manning considered necessary to comply with the provisions of paragraph 1. Vessels watch call system extension alarm panel is inoperable. Alarm panel was found to be inoperable on 21DEC17 and company was notified accordingly. Vessel has no documentation from company for notification to Class/Flag. Vessel is classed for an unattended machinery space and its minimum safe manning reflects "If the UMS or bridge control systems are not operational than an engineering watchkeeping officer (Reg. III/1) and an engine rating (Reg. III/4) must be carried out in addition to the above." Vessel has been sailing without additional engineering crew members since 21DEC17, as required by the Vessels Minimum Safe Manning Document. SOLAS (2014 CONS) CH. V / Reg. 14.2.2 Action Taken: 30abc
Action required: 705 - Other - as specified
Resolved 22 February 2018
Resolution: To the satisfaction of the Coast Guard.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 February 2018 Resolved
Every oil fuel pipe, which if damaged, would allow oil to escape from a storage, settling or daily service tank situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occuring in the space in which such tanks are situated. Upon examination of the remote fuel shutoff for the vessels emergency diesel generator, it was discovered to be seized to the deck rendering it inoperable in the case of fire or other emergency. SOLAS (2001 cons.) CH. II-2 / REG. 15.2.5 Action Taken: 30ac
Action required: 705 - Other - as specified
Resolved 22 February 2018
Resolution: To the satisfaction of the Coast Guard.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 18 February 2018 Resolved
2550- The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. As per the Liberty one Shipmanagement "Instructions for Maintenance Work", The vessels emergency diesel generator and its quick closing valves are to be checked at weekly intervals by the chief engineer. PSCO discovered the quick closing valve on the emergency diesel generator to be seized to the deck rendering it inoperable in the event of an emergency. A review of onboard maintenance records indicate that the system was inspected satisfactorily with no issues observed. SOLAS (2014 cons) CH. IX / Reg. 3.1 ISM Code (2014) / 10.1 Action taken 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2018
Resolution: To the satisfaction of the Coast Guard.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 11 February 2017 Resolved
2110-Oil/Oily mixtures Machinery-Oil filtering equipment shall be of design approved by Admin, ensure oil content discharge does not exceed 15 PPM. MEPC.60(33) system has discharge connection installed for port state control testing valve (one way) is not installed to prevent bypass. (Current arrangement allows for bypass to overboard discharge valve when open).MARPOL ANNEX I/14.6
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 4 March 2017
Resolution: SEC HOU-GAL PSC received a class report from DNVGL satisfying the requirement. Vessel installed one-way check valve in the oily water overboard piping before the test valve meeting MARPOL requirements.
Engineering › Steering Gear System › Power Unit
Issued 20 October 2010 Resolved
1030-Steering Gear Alarm- In the event of a power failure to any of the steering gear power units, an audible and visual alarm shall be given on the navigation bridge. The number 1 steering gear pump did not give an audible and visual alarm on bridge for power failure. Have certificate issuing authority attest to proper operations and repair of power failure alarm. SOLAS 2004 II-1/29
Action required: 705 - Other - as specified
Due 1 November 2010
Resolved 14 December 2010
Resolution: Received class report from Lloyd''s Register of Shipping satisfying requirement.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 22 March 2010 Resolved
Vessel reported fluke on PORT anchor missing prior to entry into Port of Houston. Vessel was placed under OPCON requiring class to attest to condition found and place condition of class on vessel. Class has requested vessel to have tug escort while entering or departing port until repair is made.
Action required: 705 - Other - as specified
Due 10 June 2010
Resolved 29 June 2010
Resolution: Received a class report allowing the vessel to transit with certain stipulations. See (port anchor.pdf) in documents
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 25 May 2005 Resolved
Vessel does not have vessel specific Ballast Water Management Plan onboard.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 October 2005
Resolution: Vessel was found with a vessel specific Ballast Water Management plan onboard
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 24 February 2005 Resolved
The vessel wishes to enter the Port of New York with a hydraulic malfunction of its controllable pitch propeller that resulted in a loss of ship's propulsion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2005
Resolution: The vessel submitted a causal analysis plan and repairs have been made along with approval from Lloyd''s Register.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.