CALIFORNIA SPIRIT is a 2004 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2016, most recently in June 2026, along with 54 deficiencies and 2 casualty investigations in 2012.

Records from 2012 to 2026. Most recent: inspection, 23 June 2026.

Built
2004
Last inspected
23 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8990500
WDC4041
730501
Flag
UNITED STATES
Maury page id
psix-730501

Documentation record

Registered dimensions (L × B × D)137.8 ft × 37.0 ft × 13.5 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)137.8 ft × 37.0 ft × 13.5 ft
ITC tonnagegross 816 / net 285
BuilderKEITH MARINE INC · PALATKA, FL, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it816 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
285 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

23 June 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8412146
22 April 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8353992
27 January 2026 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8330398
14 May 2025 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8136238
21 November 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8038772
26 September 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8010186
2 May 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7905515
18 September 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7838772
7 April 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7667625
17 October 2022 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7581305
23 September 2022 Examination of Repairs · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7565264
21 April 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7448678
12 March 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7410637
22 September 2021 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7317826
22 June 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6984080
21 May 2020 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6957015
4 May 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7014127
31 July 2019 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6766613
31 January 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6618282
26 July 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6485693
1 May 2018 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6403141
1 August 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6227176
28 November 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6048736
9 November 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6038230
27 July 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5954549

Deficiency record · 54

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2026 Resolved
Dead end wiring in engine room, cap and secure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2026
Resolved 13 July 2026
Resolution: Deficiency resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2026 Resolved
01 gate valve could not close, replace with operational valve.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2026
Resolved 13 July 2026
Resolution: Deficiency resolved.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 September 2024 Resolved
Spanner wrenches must be provided for each fire hydrant required by this regulation. Existing vessels must comply with this requirement by January 18, 2017. Numerous hydrant stations missing spanner wrench. Provide spanner wrenches at all fire hydrants.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2024
Resolution: observed spanner wrenches at fire stations
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 September 2024 Resolved
For portable fire extinguishers the owner or managing operator shall provide satisfactory evidence of the required servicing to the marine inspector. Portable CO2 extinguisher in bow thruster room not serviced in past year. Provide servicing on extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2024
Resolution: Observed servicing record.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2024 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Support for bow thruster cable not present. Fitting into controller box loose. Provide wire support and tighten fitting going into controller box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2024
Resolution: Observed tightness of fitting
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 September 2024 Resolved
A hatch cover must have captive chains, or other devices of substantial strength to prevent its loss. Port side hatch missing captive chain. Provide chain.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2024
Resolution: Observed chain, via photo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 September 2024 Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. Engine room and freezer emergency exits could not be opened by one crew member from the interior. Make emergency exits operational from inside.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2024
Resolution: interior scuttle was observed operational
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 September 2024 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the cognizant [name withheld] extinguisher in galley not mounted. Provide bracket for extinguisher and ensure it is mounted IAW fire control plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2024
Resolution: Observed bracket mounted IAW fire control plan
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 26 September 2024 Resolved
Combustibles insulated from heated surfaces. Galley uptakes, and similar sources of ignition must be kept clear of and suitably insulated from combustible material. Grease in hood/uptake system. Clean grease from uptake system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2024
Resolution: Observed clean up-take, VIA photo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 September 2024 Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. Galley was not sanitary. Provide sanitary galley.
Action required: 705 - Other - as specified
Resolved 27 September 2024
Resolution: Observed cleanliness of vessel, all SAT
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 26 September 2024 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Marking on bow for life jackets gone. Provide marking for life jacket storage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2024
Resolution: Observed proper marking on brow for life jacket storage.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2024 Resolved
Multiple fire screen doors were found with carpet passing through the doorway. Provide a metal threshold for each fire screen door which currently has carpet passing through it.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2024
Resolution: POC provided image of metal threshold. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2024 Resolved
Both the lower deck and upper deck bars were found with electrical power strips providing power to high amperage coffee warmers. Provide dedicated electrical outlets with proper amperage rating for each bar coffee station.
Action required: 10 - Deficiency Rectified
Resolved 26 September 2024
Resolution: Vessel removed power strip and coffe station
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2024 Resolved
The lower deck bar dishwasher was found with an extensions cord providing power to the equipment. The extension cord had no ground prong and the hot/neutral plug prongs were found to be burned from excess heat. Provide dishwasher with a dedicated 20-amp circuit and 12 AWG sized boat cable for permanent wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2024
Resolution: Vessel had wired dishwasher to a dedicated 20AMP circuit with 12AWG cable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2024 Resolved
The electrical outlet in the forward / stbd galley was found to be burned from excess heat. Replace outlet and verify wiring is serviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2024
Resolution: Observed repairs, All SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 September 2024 Resolved
The electrical cable transit on the aft bulkhead of the stores compartment was not properly sealed. Provide cable transit with proper sealant.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2024
Resolution: Observed cable with fire stop sealant.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2023 Resolved
Bilge pump system found to be inoperable, ensure all check valves are working order, retest in the presence of marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2023
Resolution: O/O repaired check vlvs, and retested
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 October 2022 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2” high: EMERGENCY EXIT KEEP CLEAR. Must mark all exits throughout vessel. 21OCT22 vsl requested and a 30 day ext was approved.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 September 2024
Resolution: Observed signage, all SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 October 2022 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. The pressure switches for the Fixed CO2 system were taken apart for the vessels re power and not reinstalled after. The system would not shut down the main engines when tested.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2022
Resolution: Attended the vessel and verified compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 October 2022 Resolved
Each Lifeline on a ring buoy must have a breaking strength of at least 1124 pounds. One life ring's lifeline was corroded to the point of failure and must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 October 2022
Resolution: Attended the vessel and verified compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 October 2022 Resolved
Each floating waterlight must be approved in accordance with 46CFR161.010. One of the water lights on board the vessel was inoperable due to a inoperable battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 October 2022
Resolution: Attended the vessel and verified compliance.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2022 Resolved
Electrical dead-ended cables not properly terminated in the wheelhouse below the helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 October 2022
Resolution: Attended the vessel and verified compliance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 October 2022 Resolved
Port Engine Display was inoperable due to re-power. Demonstrate satisfactory operation of the Port Engine Display to include the RPM, jacket water discharge temperature and lubricating oil pressure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 October 2022
Resolution: Attended the vessel and verified compliance.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 October 2022 Resolved
Fire extinguisher was missing from its bracket following dry dock period. Ensure all fire extinguishers are found and properly installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 October 2022
Resolution: Attended the vessel and verified compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 September 2021 Resolved
Adult life jacket count; 695. Missing additional 5.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 23 September 2021
Resolution: Received purchase receipt of 05 newly procured life jackets. [name withheld].
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 September 2021 Resolved
Portable fire extinguisher at STBD Aft quarter missed servicing date of SEPT 2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 20 October 2021
Resolution: Owner operator had Tech service extinguisher.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 September 2021 Resolved
Port and STBD MDE Start battery bank; need blocking to prevent shifting.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 20 October 2021
Resolution: O/O securely fastened batteries in place.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 September 2021 Resolved
Overhead light not working in steering gear room and galley cook area. Repair / replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 20 October 2021
Resolution: O/O replaced light in steering room and galley area
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 September 2021 Resolved
Void space below aft male & female head has 6 inches of standing water; remove water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 20 October 2021
Resolution: o/o removed water.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 September 2021 Resolved
Abundant amount of oily rags were discovered in the bilge of the engine room All rags must be removed from bilges to eliminate potential fire hazards.
Action required: 10 - Deficiency Rectified
Due 22 September 2021
Resolved 22 September 2021
Resolution: O/O removed oily rags from bilge.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 September 2021 Resolved
Hatch to bow thruster was not attached to frame or coaming. Re attach hatch cover to prevent its loss. Cite: 46 CFR 116.1160(b)(2).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 20 October 2021
Resolution: O/O added chain from hatch frame to scuttle hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 September 2021 Resolved
Missing label on bilge manifold system. Replace label for proper valve and compartment identification.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2021
Resolved 6 October 2021
Resolution: O/O replaced missing placard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 June 2020 Resolved
On the vessel transom, located port side. A shipboard light is installed and broken which will allow water into the lazeratte. Ensure bulkhead penetration is made watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 27 July 2020
Resolution: LIGHT REPAIRED AND SEALED.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 June 2020 Resolved
Ensure Galley ventilation ducting is throughly cleaned and free from grease and oily residues that present a fire hazard.
Action required: 705 - Other - as specified
Resolved 26 June 2020
Resolution: cleaned and degreased
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 22 June 2020 Resolved
Properly adjust Machinery Space Watertight door to ensure proper fit and closure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 27 July 2020
Resolution: DOOR ADJUSTED FOR PROPER CLOSURE
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 June 2020 Resolved
Ensure all Watertight door closure indicators are operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 26 June 2020
Resolution: all WTD indicators are operational
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2020 Resolved
01 Portable Fire Extinguisher is missing from main deck. Install the proper extinguisher IAW vessels Fire Control Plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 26 June 2020
Resolution: replaced
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 June 2020 Resolved
Ensure all CO2 storage cylinders are installed at least 2 inches of the deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 27 July 2020
Resolution: SPACERS INSTALLED
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 June 2020 Resolved
Ensure control stations for machinery are protected from unauthorized access and clearly marked restricted and indicate that unauthorized access to those controls constitutes a breach of security. Ensure VSP is updated accordingly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 27 July 2020
Resolution: CONTROL STATIONS MARKED
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 May 2020 Resolved
Due to circumstances arising as a result of COVID-19, the COI Inspection and Dry-Dock for the vessel, originally due on 05MAY2020, has been deferred for 90 days. The circumstances which necessitate this deferment are beyond the control of the Master. The vessel must complete the required renewal COI Inspection prior to 03AUG2020. If circumstances necessitating this deferment remain after this 90-day period, you must submit a request to extend this deferment. This deferral is only valid for the above-mentioned inspections. This CG-835V shall be maintained aboard the vessel until the required inspection has been completed.
Action required: 705 - Other - as specified
Due 4 August 2020
Resolved 23 June 2020
Resolution: COI Inspection Complete.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 July 2019 Resolved
Replace plastic waste receptacles with non-combustible type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 30 August 2019
Resolution: Replaced plastic waste cans with metal cans.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 July 2019 Resolved
Properly label lifejacket storage containers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 30 August 2019
Resolution: Labeled lifejacket storage.
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 31 July 2019 Resolved
Update Fire Control Plan to reflect safety equipment location and quantity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 9 October 2019
Resolution: FCP updated.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 July 2019 Resolved
Replace 2 defective emergency lighting fixtures as identified.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 30 August 2019
Resolution: Replaced lights.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 July 2019 Resolved
Repair 2 defective generator housing clips on port side generator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 30 August 2019
Resolution: Replaced clips.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 July 2019 Resolved
Provide first aid instructions.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 September 2019
Resolved 31 July 2019
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 31 July 2019 Resolved
Install phone extension directory in starboard side, aft call box.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 30 August 2019
Resolution: Installed call list.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 July 2019 Resolved
Repair defective fire door latch on aft, main deck fire door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 30 August 2019
Resolution: Door latch replaced.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 1 August 2017 Resolved
Diagnose and repair improperly functioning port main diesel engine controls
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 August 2017 Resolved
Conduct MOB drill in presence of USCG
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Fire Fighting › Structural - Main Vertical Zones › General
Issued 1 August 2017 Resolved
Provide noncombustible handrail in elevator
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 2 October 2017
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 27 July 2016 Resolved
Remove or stow E/R clutter properly
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 30 August 2016
Resolution: Cleared defs
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 27 July 2016 Resolved
Provide 03 PFDs. Vessel reduced to 597 pax
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 30 August 2016
Resolution: Cleared def
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 July 2016 Resolved
Provide serviceable fire extiguisher for bow thruster room
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 30 August 2016
Resolution: Cleared def

Casualty record · 2

13 January 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4235407
25 March 2012Routine · role: Involved in a Marine Casualty · activity 4272146
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.