Records in 2016. Most recent: inspection, 16 December 2016.
Documentation record
Registered dimensions (L × B × D)38.5 ft × 8.5 ft × 3.7 ft
Registered tonnagegross 8 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTROLLEYBOATS LLC · HOLLY HILL, FL, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 1 December 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 14 February 2017
No resolution recorded
Provide pre-engineered fixed gas fire extinguishing system approved by the Commandant. Complete prior to carrying passengers for hire. Vessel's pre-engineered fixed gas fire extinguisher found inadequate to cover required 1100 cubic feet of space, current volume of extinguisher was found to have only 350 cubic feet of volume coverage.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2017 — due date passed with no resolution recorded
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 February 2017
No resolution recorded
Provide proper proof of repairs to exhaust piping discovered leaking gas; prior to carrying passengers for hire.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2017 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 February 2017
No resolution recorded
Arrange Reverso Pumps oil change system to a location preventing any hazardous conditions and as recommended by the manufacturer. Complete prior to carrying passengers for hire.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2017 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Ventilation › General
Issued 14 February 2017
No resolution recorded
Properly arrange smaller cooling fan, located next to fixed gas fire extinguisher, as to not interfere with the release of a clean agent when activated. Complete prior to carrying passengers for hire.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2017 — due date passed with no resolution recorded
Fire Fighting › Combustible Materials › Insulation
Issued 14 February 2017
No resolution recorded
Provide proper insulation of engine exhaust piping. Complete prior to carrying passengers for hire.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2017 — due date passed with no resolution recorded
Operations/Management › Vessel Activity › Construction/Repair
Issued 16 December 2016
No resolution recorded
Due to the maintenance conducted to the rear axle tower and transfer case, the vessel can not carry passengers until a satisfactory Coast Guard inspection is conducted.
Action required: 705 - Other - as specified
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 19 April 2016
Resolved
Provide recent MIS report.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 3 May 2016
Resolution: MIS report provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 April 2016
Resolved
Provide ring buoy waterlight lanyard (Clip)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 3 May 2016
Resolution: Ring buoy with waterlight lanyard (Clip) provided.
Documentation › Certificates/Documents › Stability Letter
Issued 19 April 2016
Resolved
Provide Stability Letter onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 3 May 2016
Resolution: Stability Letter provided onboard.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 April 2016
Resolved
Provide retro reflective tape to ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 3 May 2016
Resolution: Retro reflective tape added to ring buoy.