← All vessels
POP POP
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named POP POP
POP POP is a 2004 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2004, most recently in December 2025, along with 25 deficiencies, 4 operational controls, 1 with no removal date recorded and 1 casualty investigation in 2018.
Records from 2004 to 2025. Most recent: inspection, 13 December 2025.
- Built
- 2004
- Last inspected
- 13 December 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
- Casualties
- 1 investigation · 2018
Identity
1165452
WDJ8340
731265
Flag
UNITED STATES
367642610 (licence lapsed)
Maury page id
psix-731265
Inspections, by type
…with no type recorded2
Years with a record
13 calendar years (2004–2025)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)42.0 ft × 11.0 ft × 4.5 ft
Registered tonnagegross 13 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCANAL BOATS INC · FORT LAUDERDALE, FL, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portFORT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
11 - Simplified, Net Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDH6890MMSI 367642610 · expired · compulsorily equipped · granted 3 October 2014, cancelled 7 December 2024 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 23
13 December 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8353586
18 November 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8270012
18 November 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8036209
25 October 2024
Simplified Stability Test · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8033236
8 November 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7347238
16 January 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6611181
2 July 2018
In-Service Inspection · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6464862
2 July 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6495174
23 June 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6453083
21 June 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6452148
20 March 2018
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6372515
20 February 2018
Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6359298
5 January 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6064199
20 October 2016
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6030498
19 July 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5945652
5 January 2016
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5791220
23 February 2011
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3961343
23 February 2010
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3684785
26 February 2009
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3424440
17 January 2008
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3132104
10 January 2008
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3128014
22 March 2006
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2608746
15 December 2004
Construction Oversight · Initial Certification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2258037
Deficiency record · 25
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 January 2019
Resolved
Vessel is overdue for annual inspectiion as of 09JAn19.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 July 2018
Resolved
Vessel lost throttle control to electric motor that turns shaft. Attestation of technician conducting repairs required.
Personnel › Training › Fire Fighting Basic
Issued 5 January 2017
Resolved
Conduct and log crew training for lifesaving and firefighting to include all emergency procedures.
Fire Fighting › Fire Pumps › Pressure
Issued 5 January 2017
Resolved
Ensure fire pump is fully operational.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 January 2017
Resolved
Provide guard for generator belt pulley.
Electrical › Electric Supply System (service) › Battery Charger
Issued 5 January 2017
Resolved
Remove portable battery charger. If applicable, install permanent charger.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 January 2017
Resolved
Properly label fuel shut off valve.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 5 January 2017
Resolved
Companywide training required for all persons operating/working on Water Shuttle II and other vessels of similar design. Training to match emergency procedures.
Documentation › Safety Management System › Potential Emergency Situations ID Procedures
Issued 5 January 2017
Resolved
Update emergency procedures to address particular arrangements for vessel. Mount those updated procedures.
Construction/Loadline › Hull › Bottom Plating
Issued 19 July 2016
Resolved
Sand down affected bow portion to good fiberglass. Submit repair proposal to USCG Sector Miami for approval. Prior to credit drydock.
Stability › Unintentional Flooding › General
Issued 19 July 2016
Resolved
Blank off the port side aft valve not being used. Prior to credit drydock.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 July 2016
Resolved
Ensure cables throughout the vessel are properly secured with proper brackets. Due 02AUG16. (many cables were secured only with plastic zip ties, not the required metallic/rubber bracket type).
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 February 2011
Resolved
Provide original COD.
Operations/Management › Drills/Instruction › Fire
Issued 23 February 2011
Resolved
Post operating instructions for the bilge and fire main system.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 February 2011
Resolved
Mark high level bilge alarms.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 February 2011
Resolved
Prove proper operations of shut downs for fixed firefighting system.
Engineering › Bilge Water Management System › Pump
Issued 23 February 2011
Resolved
Test fire pump and bilge pump.
Operations/Management › Drills/Instruction › Fire
Issued 23 February 2011
Resolved
Post emergency instructions
Electrical › Electric Generation Source (service) › Conductor
Issued 15 December 2004
Resolved
Battery cable on positive side of battery is loose.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 15 December 2004
Resolved
Pre-engineered fixed gas system in the Generator room does not shut down the generator when activated.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 December 2004
Resolved
Provide U/L approved smoke detector IAW 46CFR181.450 for the vessel's accommodation space.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 December 2004
Resolved
Lifering buoy does not have the name of vessel stenciled, does not have retro-reflective tape, and the line is the wrong color (should be dark).
Engineering › Fuel Oil Service System › Hose
Issued 15 December 2004
Resolved
Fuel line on supply side of fuel filter to the Main Generator has only one clamp on the fuel hose. Several other hoses only have one clamp.
Construction/Loadline › Hull › Bottom Plating
Issued 15 December 2004
Resolved
Provide laminate test results for hull as required by ABS standards.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 15 December 2004
Resolved
Correct electrical plans to include cable sizes.
Casualty record · 1
23 June 2018Routine · role: Involved in a Marine Casualty · activity 6453083
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
WATER SHUTTLE II (2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.