MAURY USCG vessel records Sign in
← All vessels

SEAWAYS ANTIGMAR

SEAWAYS ANTIGMAR is a 2004 tank ship. The Coast Guard has recorded 25 inspections since 2001, most recently in July 2018, along with 2 deficiencies and 4 operational controls.

Records from 2001 to 2018. Most recent: inspection, 5 July 2018.

Built
2004
Last inspected
5 July 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9271834 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
731849
Flag
MARSHALL ISLANDS
—
Maury page id
psix-731849

Inspections, by type

…with no type recorded9
Years with a record 12 calendar years (2001–2018)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it30018 - Convention (Subpart B), Gross Ton
11781 - Convention (Subpart B), Net Ton
46168 - Dead Weight, Ton
56363 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

5 July 2018 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6467193
16 July 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6207690
6 July 2016 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5931332
6 July 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5931495
6 July 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5983878
17 June 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5902372
6 March 2014 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4806425
15 February 2012 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4244669
8 February 2012 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4229961
1 February 2011 ISPS II Exam · Ballast Water Examination · COC-CHEM Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3935430
28 January 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3935098
7 January 2010 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3659766
31 May 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2947741
27 May 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2942057
9 March 2007 ILO-147 Exam · COC-CHEM Renew · Loadline Exam · Ballast Water Examination · STCW 95 Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2884631
26 September 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2787549
23 September 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2785186
21 March 2006 ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2606420
2 January 2006 Spot Check · COC-TVE Annual
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2556133
15 September 2005 ISPS II Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2493129
10 June 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2382836
22 May 2005 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2364702
9 December 2004 COC-TVE Renew · ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2278192
8 December 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2270153
1 February 2001 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3736059

Deficiency record · 2

Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 8 February 2012 Resolved
After several attempts to perfom functional test on the inert gas generating system, the PSCO cited the following: The inert gas system shall be constructed and tested in accordance with the FSS Code 74 SOLAS (2004 CONS) II-2/4.5.5.3.2//////suitable means shall be provided for the zero and span calibration of both fixed and portable gas concentration measurement instruments referred to in paragrap
Action required: 705 - Other - as specified
Due 22 February 2012
Resolved 15 February 2012
Resolution: Received confirmation from the vessel master that they received the span gas to test the ships IGG system. All checked satisfactory.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 1 February 2011 Resolved
PSCO'S FOUND THAT THE BATTER ON THE EPIRB WAS EXPIRED. VESSELS MANAGEMENT WAS NOTIFIED THAT VESSEL MUST RECIEVE NEW BATTERY PRIOR TO DEPARTURE FROM ST. CROIX.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2011
Resolved 1 February 2011
Resolution: VESSEL PUT INTALLED A NEW BATTERY AND EPIRB WAS OPERATIONAL.

Ownership record