Inspection history · 39
2 June 2026
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8387100
7 August 2025
Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8205228
7 August 2025
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8217621
10 June 2025
COI Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8156513
14 August 2024
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7989626
13 June 2024
Annual Inspection · Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7908489
8 August 2023
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7762431
6 June 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7677158
30 January 2023
DAPI Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7696296
2 September 2022
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7552233
5 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7491699
5 October 2021
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7327086
7 September 2021
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7307277
22 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7232933
5 March 2021
Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7150984
14 August 2020
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7035509
28 July 2020
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7018053
7 May 2020
Initial Certification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6955300
9 May 2019
DAPI Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6681005
26 April 2017
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6152502
24 November 2015
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5770108
24 April 2014
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4851630
10 May 2011
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4022046
23 June 2008
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3245596
17 June 2008
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3241200
18 August 2006
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2758289
16 November 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2536427
28 February 2005
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2300760
10 February 2005
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2301233
6 February 2005
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2290248
28 January 2004
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2000978
22 November 2002
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1709357
19 November 2002
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1709329
28 August 2002
Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1667508
9 January 2001
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 211928
1 November 2000
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 823575
9 January 2000
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 286389
5 January 1997
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 50882
9 December 1995
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1078925
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2026
Resolved
All machinery and equipment that is not in proper working order . . . must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. Vessel's stern capstan was found to be disassembled with electrical wires disconnected and left exposed. The power to the capstan was turned off, but not locked out or tagged out in any way. Company policy requires electrical lockout before machinery is repaired. Switch was locked out while CG was onscene and vessel rep was made aware of the procedures company shore-side maintenance personnel failed to follow.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 3 June 2026
Resolved 3 June 2026
Resolution: Circuit was tagged out during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 June 2026
Resolved
The following systems must be equipped with gauges at the machinery location: main engine RPMs. Both main engines had RPM gauges installed, but neither were operable. Repair/replace RPM gauges for both main engines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 10 July 2026
Resolution: Observed all gauges watching properly.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 June 2026
Resolved
Observed that various void space and tank hatch covers lacked required markings & some dangerously mislabeled, such as a fuel tank hatch labeled as "water." Verify and properly mark all voids and tanks to accurately reflect their actual contents and purpose IAW 46CFR144.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 30 June 2026
Resolution: Covers have been properly labeled.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 June 2026
Resolved
A towing vessel must carry adequate and up-to-date nautical publications for the intended voyage. Vessel's Light List was dated 2014 and uncorrected. Vessel's crew utilizes electronic versions of some publications, but had no electronic backup (or paper copies) should the device fail to operate. Ensure all required nautical publications are currently corrected, and if using electronic versions be sure to have redundant system in place or paper copies as back up.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 30 June 2026
Resolution: Light list updated and backups provided for any electronic publications utilized.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 July 2025
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Rail stanchion located on the port-side, aft on the deck just below and aft of the pilot house has broken free of its connection to the deck. Re weld this stanchion to the deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2025
Resolved 1 August 2025
Resolution: Stanchion has been reattached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Electrical systems must minimize system failures and shock hazards. In the vessel engine room the following was discovered: multiple electrical splices not in enclosures and multiple sensor wires not properly supported and protected from chafing and vibration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2025
Resolved 1 August 2025
Resolution: Verified all have been rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2025
Resolved
Machinery must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard. Multiple cooling water hoses not properly supported and chafing. Properly support the hoses and install chafing gear as needed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2025
Resolved 1 August 2025
Resolution: Chafing gear and supports have been installed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 July 2025
Resolved
Towing vessels of more than 65 feet in length must carry - one 40-B portable fire extinguisher fitted in the engine room. 40-B portable fire ext. was removed from engine room to facilitate deck plate removal and not reinstalled. Reinstalled during inspection.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2025
Resolved 1 August 2025
Resolution: Installed properly.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 July 2024
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks. United Steel has recently had a Man Overboard who nearly lost their life. A causal factor of that Marine Casualty was that the handrails had been removed, allowing the fall overboard. The company was alerted of the condition and reminded of the requirement. The company assured the Coast Guard that 100% of the vessel crews had been instructed on their policy. Marine Inspectors observed USS-1 underway with their handrails removed. The Company should conduct hands on training with each employee and formally document the training.
Condition: Improper Installation
Action required: 30 - Ship detained
Due 22 July 2024
Resolved 18 July 2024
Resolution: All hands training was conducted and a roster provided.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 18 July 2024
Resolved
The owner or managing operator of a towing vessel must establish procedures to address fall overboard prevention and recovery of persons in the water. United Steel did not have a plan to prevent falls overboard. A fall prevention plan shall be developed and implemented. ALL employees shall conduct, and acknowledge, training of the fall prevention plan.
Condition: Invalid
Action required: 30 - Ship detained
Due 22 July 2024
Resolved 18 July 2024
Resolution: A fall prevention plan was developed, implemented, and trained.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2024
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Both lifebuoys were outfitted with float lights attached to spring type connectors of non-approved batteries. The proper screw post type batteries, as approved on the light, shall be installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 31 July 2024
Resolution: Conducted def check, observed properly float light batteries installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The electrical distribution panel on the pilothouse was blocked by a bench. Remove the bench and assure easy access to the panel to minimize system failures, fire, and shock.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 31 July 2024
Resolution: Bench was removed and cut to fit beside the panel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 July 2024
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. A stanchion on the port aft 01 deck is wasted and needs to be renewed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 31 July 2024
Resolution: Stanchion was cut out and new one installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2024
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. The Port side float light was inoperable. Replace battery with properly approved Battery.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 31 July 2024
Resolution: Conducted def check, observed properly float light batteries installed
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 13 June 2024
Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month. Drills are not being completed by all crew members [name withheld] and crew-members who operate this vessel must conduct fire and person in the water drills on this vessel, provide documentation attesting to completion of drills for all crew and provide proof of corrective actions taken to mitigate future occurrence.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 18 June 2024
Resolution: Drills conducted and documented as required. New tracking tool implemented to address reoccurence of deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 June 2024
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Port side ventilation louvers broken and do not close. Repair or replace as required.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 18 July 2024
Resolution: Observed succesful operation of ventilation louvers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. A/C unit in overhead of pilot house missing cover to moving / electric components. Install cover or remove unit.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 18 July 2024
Resolution: Observed installed cover.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 13 June 2024
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Top part of ladder leading to the pilot house roof waisted. Crop wasted metal and return to original condition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 18 July 2024
Resolution: Observed ladder repairs, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2024
Resolved
Each towing vessel must carry at least one appropriately-sized lifejacket, approved under approval series 160.002, 160.005, 160.055, 160.155, or 160.176, for each person on board. Life jackets are no longer orange. Destroy existing life jackets and replace with new.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 18 July 2024
Resolution: Observed new life jackets.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 June 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: high bilge levels, be visible and audible at each operating station. The high bilge alarm was not audible or visible from the pilothouse. Repair the alarm and provide OCMI with tech report and video evidence that the system is restored.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2024
Resolved 1 August 2024
Resolution: Tech report was provided along with video evidence.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 6 June 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (1) Main engine low lubricating oil pressure; (2) Main engine high cooling water temperature; (3) Auxiliary generator engine low lubricating oil pressure; (4) Auxiliary generator engine high cooling water temperature. Engine alarm panel displaying invalid readings for all parameters for port propulsion engine/reduction gear and starboard generator displaying invalid reading for water temp. Repair equipment as required and validate alarm set-points for alarms in accordance with 46 CFR 143.245(b). Once complete, provide technical repair report indicating alarm set points and proper operation to the Coast Guard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 June 2023
Resolved 8 August 2023
Resolution: Engine monitoring system repaired. Verified alarm setting for MDE & SSDG oil and jacket water alarms were set to manufacturers requirements.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 6 June 2023
Resolved
Pressure vessels must be externally examined annually. Relief valves must be tested in accordance with § 143.245 (Twice every 5 years, with no more than 3 years elapsing since last test.) Conduct testing of pressure relief valves as required or replace with new. Once complete, provide technical repair report or receipt to Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2023
Resolved 8 August 2023
Resolution: Pressure relief valves replaced with new and documented as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 June 2023
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Loose material found inside starboard generator accessory pulley guard. Remove material.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 June 2023
Resolved 27 June 2023
Resolution: Cleaned out debris
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 June 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Emergency lighting for engine room inoperable. Repair as required. Once repaired provide documentation that testing of emergency lighting has been completed in accordance with 46 CFR 143.245(b) (Every 3 months).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2023
Resolved 27 June 2023
Resolution: Emergency lighting replaced with new.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 June 2023
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Oil soaked rags, trash, oil and grease found throughout bilges in machinery spaces. Clean bilges and fix oil leaks as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2023
Resolved 27 June 2023
Resolution: Bilges cleaned
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2023
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Port propulsion engine exhaust pipe exposed. Re-attached insulation to cover exposed exhaust pipe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 June 2023
Resolved 27 June 2023
Resolution: Exhaust lagging replaced and properly installed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 5 August 2022
Resolved
The owner, managing operator, or master must ensure that all persons on board a towing vessel comply with the health and safety plan. Vessel crew and company are not in compliance with published health and safety plan on vessel. Following the procedures of the vessel health and safety plan, utilize the below deficiencies identified by the Coast Guard Marine Inspectors to demonstrate the understanding and implementation of the vessels health and safety plan.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 2 September 2022
Resolution: Documents completed as required
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 August 2022
Resolved
All fire-extinguishing systems, including ventilation, dampers on board the vessel, must be inspected or tested at least once every 12 months. Port and starboard ventilation dampers are broken. Replace/repair as required.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 6 September 2022
Resolution: Dampers replaced with new
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 August 2022
Resolved
Internal combustion engine exhaust ducts, galley exhaust ducts and similar ignition sources must be insulated with noncombustible insulation if less than 450 mm (18 inches) away from combustible material. Wood block found wedged between internal combustion engine exhaust ducts. Remove wood as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 2 September 2022
Resolution: Wood block removed from exhaust stacks
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 August 2022
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Breakers missing labels in engine room breaker panel. Add labels to breakers as required.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 2 September 2022
Resolution: Breakers labeled as required
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 5 August 2022
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. Navigation assessment not properly completed. Train vessel Masters on proper navigational assessment procedures and ensure proper documentation is completed.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 6 September 2022
Resolution: Navigation assessment properly completed as required
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 August 2022
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Oil found in bilges. Remove all acculturation of oil as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 2 September 2022
Resolution: Oil cleaned from bilges
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 August 2022
Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container that meets the requirements of § 142.225 of this subchapter. Oil found stored in engine room. Store oil in approved container as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 2 September 2022
Resolution: Oil no longer stored in engine room
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 August 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Starboard generator battery cable loose. Tighten as required.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 August 2022
Resolved 8 August 2022
Resolution: Battery terminals tightened
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 5 August 2022
Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies. Crew was found to be unfamiliar with duties expected of them. Train crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 2 September 2022
Resolution: Drills completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2022
Resolved
The Master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Found one life jacket with hole in fabric. Replace holed life jacket.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 August 2022
Resolved 8 August 2022
Resolution: Replaced life jacket with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2022
Resolved
Each lifejacket must have a lifejacket light. Two of the lifejacket lights were not working. Replace lights on the two lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 August 2022
Resolved 8 August 2022
Resolution: Replaced lights with new
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 August 2022
Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working areas. The starboard forward light fixture light bulb is extinguished. Replace the light bulb.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 2 September 2022
Resolution: Lighting fixture replaced with new
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 August 2022
Resolved
The results of the inspections required by 33 CFR 164.76 must be documented in the official or in accordance with the TSMS applicable to the vessel. Inspections of the towing equipment are not being properly logged. Ensure inspections of towing equipment required in log are completed and logged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 6 September 2022
Resolution: Inspection of tow line logged as required
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 5 August 2022
Resolved
Pressure vessels must be equipped with one or more spring-loaded relief valves. One of the pressure relief valves on the port ship’s service air tank is broken. Replace the pressure relief valve.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 2 September 2022
Resolution: Pressure relioef valve replaced as required
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 August 2022
Resolved
Machinery and systems must be maintained to provide for safe operation of the towing vessel. The following deficiencies were identified:
1) Air intake bellows on the port and starboard turbo chargers are cracked
2) Starboard reduction gear bolt loose.
Repair as required
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 2 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 6 August 2021
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to:Slips, trips, and falls. Deck plating in engine room between propulsion engines and generators not secure. Correct as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2021
Resolution: Deck plate fasteners installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2021
Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the lifejackets stowed inside the container. Lifejacket containers missing required labeling. Label as required.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 September 2021
Resolution: Updated locations with quantity.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 August 2021
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Port shaft seals leaking excessively. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 September 2021
Resolution: Labelled as required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2021
Resolved
Each lifebuoy on a towing vessel must:
Be marked in block capital letters with the name of the vessel. All lifebuoys missing vessel name. Correct as required.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 September 2021
Resolution: Lifebuoys labelled with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2021
Resolved
If a towing vessel carries only one lifebuoy, the lifebuoy must be fitted with a floating electric water light approved under approval series 161.010 or 160.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. The water light must be attached by the lanyard with a corrosion-resistant clip to allow the water light to be quickly disconnected from the lifebuoy. The clip must have a strength of at least 22.7 kilograms (50 pounds). Water light line permenatly spliced to life ring. Remove splice and attach clip as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 September 2021
Resolution: Clip installed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 6 August 2021
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. In areas where space limitations make deck rails impractical, such as at narrow catwalks in way of deckhouse sides, hand grabs may be substituted. Bow of vessel is not equipped with rails. Install rails as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 September 2022
Resolution: Railing installed
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 6 August 2021
Resolved
The owner or managing operator must implement procedures for reporting unsafe conditions and must have records of the activities conducted under this section. The owner or managing operator must maintain records of health and safety incidents that occur on board the vessel, including any medical records associated with the incidents.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 September 2021
Resolution: Procedures developed and implemented for reporting unsafe conditions.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 6 August 2021
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Port generator exhaust lagging not secured. Repair as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 September 2021
Resolution: Installed insulation over exposed exhaust.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 August 2021
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:Be maintained to ensure proper operation. Port propulsion engine air intake improperly attached. Repair as required.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 August 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 August 2021
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Record keeping insufficient in tracking completion of tests and frequency. Correct as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 September 2021
Resolution: Recordkeeping procedures established as required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2021
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Distribution panel on the port side forward bulkhead in the engine room contained closed breakers without labeling. legend was not accurate to circuits breakers. Correct as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 October 2021
Resolution: Breaker panel legend labeled according to load.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 August 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Overhead light in engine room hanging down and not secured to overhead. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2021
Resolution: Lighting fixture reattached to overhead.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Electric shore tie cap on starboard side missing. Replace as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 September 2021
Resolution: Installed shore tie cap.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2021
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to: Electrical. Electrical distribution panel in pilot house blocked by bench. Correct as required.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2021
Resolution: Bench removed providing clear access to panel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Overloading
Issued 6 August 2021
Resolved
Each towing vessel must be maintained and operated so as to A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Found excessive accumulation of liquid in engine room bilge and forward void. Correct as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2021
Resolution: Liquid removed from bilge and void.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel starboard rudder lost in allision with buoy. Repair to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 June 2020
Resolved
Remote fuel valve must be installed in the fuel piping outside of the fuel tank. Remote valve is located at engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 28 July 2020
Resolution: Vessel provided objective photographic evidence of remote fuel valve location
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 June 2020
Resolved
Life jackets must be marked with the name of the vessel. Life jackets were unmarked.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 28 July 2020
Resolution: vessel produced photographic evidence of def repair
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 30 June 2020
Resolved
Rails or equivalent protection must be installed near periphery of all deck. No protection on aft deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 28 July 2020
Resolution: vessel produced photographic evidence of def repair
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 June 2020
Resolved
Fixed fire fighting systems must be tested annually to include time delays, ventilation, shutdowns.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 28 July 2020
Resolution: Vessel removed fixed system and replaced it with 260BC
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 June 2020
Resolved
Portable fire extinguishers must be maintained annually by a certified fire ext. servicing agency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 14 August 2020
Resolution: Recieved service inspection report for portable ext.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 10 February 2005
Resolved
Propeller sheered off as a result of grounding.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 March 2005
Resolved 23 February 2005
Engineering › Steering Gear System › Rudder
Issued 10 February 2005
Resolved
Port rudder sheered off from grounding.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 March 2005
Resolved 23 February 2005
Engineering › Steering Gear System
Issued 28 January 2004
Resolved
Leaking through rudder packing excessive caused flooding of stern void. LEGACY COMPONENT DESC: Rudder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 February 2004
Resolution: Flooding of stern void investigated at C & C Mon River and found to be caused by rudder packing. Packing renewed and leak stopped.