MAURY USCG vessel records Sign in
← All vessels

BBC MINNESOTA

BBC MINNESOTA is a 2004 public freight. The Coast Guard has recorded 33 inspections since 2004, most recently in January 2024, along with 10 deficiencies and 7 operational controls, 1 with no removal date recorded.

Records from 2004 to 2024. Most recent: inspection, 5 January 2024.

Built
2004
Last inspected
5 January 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9260378 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
731922
Flag
LIBERIA
—
Maury page id
psix-731922

Inspections, by type

…with no type recorded8
Years with a record 13 calendar years (2004–2024)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9611 - Convention (Subpart B), Gross Ton
4260 - Convention (Subpart B), Net Ton
17972 - Displacement, Ton
12840 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

5 January 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7845769
17 November 2023 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7827558
6 April 2023 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7663742
5 April 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7662971
5 April 2023 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7662973
12 January 2023 PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7620437
28 June 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7489526
8 June 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7471691
2 June 2021 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7206207
10 June 2020 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6971384
3 April 2020 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6935330
18 November 2019 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6858168
16 October 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6834521
11 January 2011 Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3924885
12 December 2010 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3909293
8 December 2010 PII Safety Exam · ISPS I Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3903829
7 December 2010 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3901726
2 December 2010 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3902711
20 July 2008 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3273272
20 May 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3212134
8 May 2008 PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3197868
4 October 2007 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3073469
11 July 2007 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2993762
22 March 2007 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2892553
14 July 2006 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2712883
30 October 2005 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2526084
26 October 2005 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2517730
25 July 2005 Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2439582
20 June 2005 Ballast Water Examination · Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2390147
20 June 2005 Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2390172
13 December 2004 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2258157
12 December 2004 Type not recorded
No type recorded · GROUP HAMPTON ROADS · USCG East District (CGD-E) · Activity 2259847
8 December 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2255618

Deficiency record · 10

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 12 January 2023 Resolved
Except where otherwise stated, the normal equipment of every lifeboat shall consist of a food ration totalling 10,00 KJ for each person the lifeboat is permitted to accommodate; these rations shall be kept in airtight packaging and be stowed in a watertight container. PSCO observed 12 of the 20 rations onboard had water ingress deeming the rations nonconformal with current regulations. SOLAS (2020) III/34; LSA IV/4.4.8.12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2023
Resolved 13 January 2023
Resolution: Received Class Report rectifying this deficiency.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 3 December 2010 Resolved
0750 - Fire doors with hold back hooks not subject to central control station release are prohibited. Engine Room entrance to incinerator room has hold back hooks not subjected to control station release, 74 SOLAS (09 CONS) II-2/9.4.1.1.4.4 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 8 December 2010
Resolution: Hold backs hooks were removed in the presence of the attending Coast Guard Marine Inspector.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 December 2010 Resolved
1730 - Oil filtering equipment shall ensure that oil mixture discharged into the sea has an oil content not exceeding 15 PPM. Vsl's OCM is not operational, rendering it unable to operate the OFE in accordance to the requirements of MARPOL. Vsl to maintain the O/B valve from OFE in a closed, secure position until repairs are made. MARPOL 73/78 Annex I/14.6 16ac
Action required: 705 - Other - as specified
Due 22 December 2010
Resolved 14 January 2011
Resolution: Received class report detailing the repairs and satisfactory testing of the oily water seperator system.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 8 May 2008 Resolved
The vessel does not have record of hydrostatic test for bunker lines. The vessel is prohibited from conducting bunkering operations in U.S. waters until the bunker lines have been hydrostatically tested at 1.5 times the maximum working pressure.
Action required: 703 - Prior to bunkering operations
Due 8 May 2008
Resolved 20 May 2008
Resolution: Recieved document of corrective action.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 8 May 2008 Resolved
The Chief Engineer and Captain were unable to produce for inspection the Oil Transfer procedures as required by 33 CFR 155.720.
Action required: 703 - Prior to bunkering operations
Due 8 May 2008
Resolved 20 May 2008
Resolution: Recieved document of corrective action.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 13 December 2004 Resolved
SLED LIFEBOAT MISSING 3 FOOD RATIONS. VESSEL TO PROVIDE 3 RATIONS TOTALING NOT LESS THAN 1700KJ.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2004
Resolved 13 December 2004
Resolution: 3 RATIONS WERE DELEIVED TO VESSEL PRIOR TO DEPARTURE OF COAST GUARD INSPECTION TEAM.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 December 2004 Resolved
LIFE BUOY STVD SIDE MIDSHIPS MISSING BRACKET FOR LIGHT. THIS POSES A SERIOUS THREAT TO THE CREW DUE TO THE LIGHT NOT BEING READY FOR IMMEDIATE USE.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2004
Resolved 17 December 2004
Construction/Loadline › Structures › Ventilators
Issued 13 December 2004 Resolved
VENT DUCT FOR BOW THRUSTER ROOM ON FORCASTLE DICK WAS MISSING, WHICH REDUCES THE WATERTIGHT INTEGIRGY OF VESSEL.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2004
Resolved 17 December 2004
Resolution: Rcvd Class report
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 December 2004 Resolved
ON BRIDGE THERE ARE 2 DEAD END WIRES; ONE IS ABOVE THE GMDSS AND ONE IS ABOVE THE BRIDGE COMPUTER. WIRES ARE TO BE REMOVED OR ;OACED IN A PROPER RECEPTICLE.
Action required: 705 - Other - as specified
Due 13 January 2005
Resolved 17 December 2004
Resolution: Rcvd Class Report
Communications › Alarms/Indicators › General Alarm
Issued 13 December 2004 Resolved
MUSTER LIST DOES NOT INDICATE THE PROPER SIGNALS FOR FIRE (GENERAL ALARM) AND ABANDON SHIP. VESSEL MUST MAKE THE MUSTER LIST MATCH THE ALARMS TO BE SOUNDED IN EMEGENCIES PRIOR TO DEPARTURE.
Action required: 705 - Other - as specified
Due 13 December 2004
Resolved 17 December 2004
Resolution: Rcvd Class Report

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.