MAURY USCG vessel records Sign in
← All vessels

VERONICA PG

VERONICA PG is a 2004 tank ship. The Coast Guard has recorded 20 inspections since 2004, most recently in November 2025, along with 3 deficiencies and 3 operational controls.

Records from 2004 to 2025. Most recent: inspection, 22 November 2025.

Built
2004
Last inspected
22 November 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9285328 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
732023
Flag
ISLE OF MAN
—
Maury page id
psix-732023

Inspections, by type

…with no type recorded4
Years with a record 14 calendar years (2004–2025)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6688 - Convention (Subpart B), Gross Ton
2869 - Convention (Subpart B), Net Ton
13298 - Displacement, Ton
10632 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

22 November 2025 COC-TVE Renew · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8270961
8 January 2025 COC-TVE Annual · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8059245
13 October 2023 PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7805772
16 May 2022 PSC B · COC-TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7451724
4 May 2021 PSC B · COC-TVE Renew · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7185374
6 June 2020 COC-TVE Annual · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6969500
3 May 2019 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6669228
10 May 2018 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6406338
30 April 2017 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6133764
10 September 2016 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5996334
22 May 2008 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3206368
23 December 2007 COC-CHEM Renew · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex II Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3118838
10 September 2007 COC-TVE Annual · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3054159
27 July 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2726703
18 July 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2717622
24 June 2006 MARPOL Annex I Examination · COC-TVE Renew · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2686779
18 May 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2652830
22 July 2005 MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2435675
16 December 2004 Ballast Water Examination · ISPS II Exam · COC-TVE Annual · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2261561
15 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2259712

Deficiency record · 3

Deck/Cargo › Inert Gas System › Flue Gas Isolating Valve
Issued 10 September 2007 Resolved
Make repairs to the I.G. system. Until repairs have been made, adequatly monitor system until corrections have been made to the satisfaction of Flag/Class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Resolution: Def. Cleared. requirements written from Class/Flag
Engineering › Generator (propulsion/auxiliary-electric) › Outlet Box
Issued 10 September 2007 Resolved
Make repairs to the #3 generator to the satisfaction of Flag/Class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Resolution: Def. Cleared. requirements written from Class/Flag
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 16 December 2004 Resolved
Install signs for the High Level Alarm and for the Tank Overflow alarm as per 33CFR 153.409(d) and 408(b). 70 a,b, or c.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 21 December 2005

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.