MAURY USCG vessel records Sign in
← All vessels

MARBELLA CARRIER

MARBELLA CARRIER is a 1996 freight ship. The Coast Guard has recorded 49 inspections since 2004, most recently in August 2025, along with 18 deficiencies and 10 operational controls.

Records from 2004 to 2025. Most recent: operational control imposed, 31 August 2025.

Built
1996
Last inspected
30 August 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9063653 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
732034
Flag
MARSHALL ISLANDS
—
Maury page id
psix-732034

Inspections, by type

…with no type recorded13
Years with a record 12 calendar years (2004–2025)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it9438 - Convention (Subpart B), Gross Ton
4037 - Convention (Subpart B), Net Ton
9357 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 49

30 August 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8221379
6 December 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7604769
10 November 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7600445
19 February 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7398734
19 February 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7399894
3 August 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7275866
13 January 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7123699
16 June 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6978173
5 November 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6849353
24 January 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6614402
20 January 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6612765
23 October 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6566530
16 August 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6513656
24 July 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6488898
23 July 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6487856
15 June 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6445069
27 April 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6400722
14 April 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6391406
31 March 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6382404
17 March 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6373450
4 March 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6365436
16 February 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6356401
23 January 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6342354
13 January 2018 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6337520
8 January 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6334822
26 December 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6328848
25 December 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6328780
11 May 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6143564
29 December 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6063488
8 July 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5933729
24 June 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5917735
18 February 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5817281
18 February 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5817875
30 November 2015 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5771965
26 October 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5751375
22 August 2015 Deficiency Check · Spot Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5219314
5 August 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5202241
25 August 2014 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4965117
11 August 2014 ISPS III Exam · Ballast Water Examination · Deficiency Check · Administrative Inspection · PI Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4944826
26 June 2014 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4900573
16 June 2014 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4890485
3 June 2014 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4878594
6 May 2014 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4852014
5 December 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3109798
3 December 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3108570
14 December 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2258800
14 December 2004 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2258824
14 December 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2259104
13 December 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2260444

Deficiency record · 18

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 February 2022 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO ENSURE IT REMAINS FIR FOR SEA. WHILE TRANSITING OUTBOUND, VESSEL EXPERIENCED A LOSS OF PROPULSION. MAKE REPAIRS AND PROVIDE A CLASS REPORT ADDRESSING THE CAUSITIVE FACTORS AND CORRECTIVE MEASURES. 74SOLAS(2020CONS)I/11
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 February 2022
Resolved 19 February 2022
Resolution: Received class report.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 June 2020 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the shipor persons on board. PSCO discovered port side pilot embarkation point railing gate rusted fast and incapable of being opened.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2020
Resolved 16 June 2020
Resolution: PSCO observed embarkation railing gate opened before departure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 June 2020 Resolved
Every totally enclosed life boat shall be provided with a rigid hatch which can be closed to make the lifeboat watertight. PSCO discovered lifeboat access hatch with a wasted gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 16 June 2020
Resolution: Crew replaced gasket on hatch and PSCO observed new gasket.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 30 November 2015 Resolved
74SOLAS(09)II-2/14.2.1: Fire detection and fire alarm systems shall be kept in good order as to ensure their required performance if fire occurs. Ship's CO2 room was found with their flexible hoses that connect the cylinders to manifold to be deteriorated and some worn to the metal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2015
Resolution: Class Report: The ship's fixed CO2 hoses were replaces with type approved hoses by Wilhelmsen Ships Service on 01Dec2015. Attending surveyor inspected CO2 room and extended the scope of survey to a general safety equipment inspection with no remarks.
Engineering › Generator (propulsion-electric) › Receptacle
Issued 30 November 2015 Resolved
74SOLAS(09)II-2/26.1: The machinery, boilers, and other pressure vessels, associated piping systems and fitting shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce at minimum and danger to persons on board. The incinerator and emergency generator were found to have fuel leaks.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2015
Resolution: Class Report: The incinerator and emergency generator and associated piping were found free of leaks. Attending surveyor additionally conducted a general examination of the vessel's machinery space and piping with no remarks.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 30 November 2015 Resolved
74SOLAS(09)I/11: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to process to sea. Observed on ship's bridge were 04 windows painted over so that there is no visibility. When asked reason, it was stated to keep out heat.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2015
Resolution: Class Report: Attending surveyor observed all windows on Navigation Bridge to be free of paint. Vessel crew removed paint.
Electrical › Electric Generation Source (service) › Panelboard
Issued 30 November 2015 Resolved
74SOLAS(09)II-1/45.2: Main and emergency switchboards shall be arranged as to give easy access. Where necessary, nonconducting mats or gratings shall be provided at the front and rear of switchboard. Mats were missing but then found and provided in appropriate place.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 30 November 2015
Communications › Internal Communications System › Sound-powered Telephone
Issued 30 November 2015 Resolved
74SOLAS(09)II-1/37.1: At least two independent means shall be provided for communicating orders from the navigation bridge to the position in the machinery space or into control room. During exam, sound powered phone failed. Ship's engineering dept fixed/ comms now operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 30 November 2015
Lifesaving › Lifeboat › Windows/Translucent Panels
Issued 5 August 2015 Resolved
SOLAS 74 (97 CONS) III / 41.7.13 EVERY LIFEBOAT SHALL BE SO ARRANGED THAT AN ADEQUATE VIEW FORWARD, AFT AND TO BOTH SIDES IS PROVIDED FROM THE CONTROL AND STEERING POSITION FOR SAFE LAUNCHING AND MANOEUVERING. WINDOWS FOUND CRACKED ON FREE FALL LIFEBOAT.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2015
Resolution: 06AUG15: RECEIVED CLASS BV LETTER STATING ALL SUN DAMAGED AND CRACKED WINDOWS ON FREE FALL LIFEBOAT WERE REPLACED WITH NEW ONES BY MANUFACTURE''S AUTHORIZED SERVICE COMPANY.
Engineering › Sea-water System (primary cooling) › Valve
Issued 5 August 2015 Resolved
SOLAS 74 (09 CONS) I / 11 (a) 2 CEMENT BOX PATCHES WERE FOUND ON SALT WATER PUMPS NUMBER 1 AND 2 INLET VALVES.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2015
Resolution: 06AUG15: RECEIVED CLASS BV LETTER STATING A CONDITION OF CLASS HAS BEEN ISSUED TO RENEW THE VALVES NO LATER THAN 3 MONTHS.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 August 2015 Resolved
SOLAS 74 (04 CONS) II-1 / 40.1.3 ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT: THE SAFETY OF PASSENGERS, CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. LIGHTING FIXTURES IN ENGINE ROOM CONTAIN EXPOSED WIRES.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 August 2015
Resolution: Class has certified full inspection of engine room lighting. All wiring issues have been corrected.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 5 August 2015 Resolved
SOLAS 74 (09 CONS) V / 22.1.9.4 CLEAR-VIEW WINDOWS SHALL BE PROVIDED AT ALL TIMES. THE BRIDGE WINDOW IN FRONT OF THE HELM IS CRACKED.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 October 2015
Resolution: Recieved Class report attesting to the repair of windows.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 5 August 2015 Resolved
SOLAS 74 (04 CONS) II-1 / 26.1 THE MSD WAS FOUND TO HAVE SMALL LEAKS.
Action required: 705 - Other - as specified
Resolved 22 August 2015
Resolution: Class Survey certifies temporary repair. Class directs full repair to be completed at vessel''s next dry dock - October 2015
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 5 August 2015 Resolved
33 CFR § 160.212 (a) ALL VESSELS MUST SUBMIT NOAs WITHIN THE TIMES REQUIRED. 14 DAYS PRIOR TO ENTERING THE U.S. ALL DOCUMENTS REQUIRED BY CVC-2 LETTER 16711 / MARBELLA CARRIER DATED JAN 05, 2015 MUST BE SUBMITTED TO CVC-2.
Due 5 September 2015
Resolved 22 August 2015
Resolution: Vessel has provided all necessary documentation to CVC-2 via email. Observed and confirmed by CG PSCE team
Construction/Loadline › Structures › Door
Issued 11 August 2014 Resolved
1270 - Enclosed superstructures shall be fitted with doors of steel or other equivalent material, permanently and strongly attached to the bulkhead, and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed. PSCO found 02 aft galley doors not weathertight. - ICLL Annex I Ch.II/12.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 25 August 2014
Resolution: All access openings in bulkheads at ends of superstructures were examined and tested, including doors mentioned in the last PSC inspection, verified its closing means and weathertightness, found in satisfactory condition by Class.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 August 2014 Resolved
0945 - The survival craft, its launching appliance, and the area of water into which it is to be launched shall be adequately illuminated by lighting supplied from the emergency source of electrical power. PSCO found port side aft life raft emergency lighting to be inoperable. 74 SOLAS (97) III/15.7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 August 2014
Resolution: PSCO verified that emergency lighting was repaired. All lights operational.
Lifesaving › Lifeboat › Markings
Issued 14 December 2004 Resolved
MEANS OF IDENTIFYING THE SHIP TO WHICH THE LIFEBOAT BELONGS IS NOT MARKED/VISIBLE FROM ABOVE. CITE: LSA CODE, CH. IV 4.4.9.3. MUST BE CORRECTED BY 31MAR05 (LIFEBOAT IS A FREEFALL LIFE BOAT AND IT IS NOT SAFE TO PUT ON DUE TO ANGLE OF LIFEBOAT. 31MAR05 IS THE NEXT SCHEDULED TIME OF LAUNCHING LIFEBOAT).
Due 31 March 2005
Resolved 5 December 2007
Resolution: Call sign has been affixed to the top side IAW the LSA Code.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 December 2004 Resolved
MSO PHILADELPHIA ISSUED LOD 48-04 TO M/V PIERRE DOUX FOR INOPERABLE 3CM RADAR
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2004
Resolved 15 December 2004
Resolution: INOP RADAR INSPECTED AND TESTED TO THE SATISFACTION OF THE REPAIR TECHNICIAN. LOD 48-04 RESCINDED.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.