Records from 2005 to 2026. Most recent: inspection, 6 January 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
6 January 2026
Annual Inspection · Administrative Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8290854
12 December 2024
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8048530
14 August 2024
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7982591
1 August 2024
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7976410
7 July 2023
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7738458
29 May 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7719892
3 January 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7636551
21 June 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7482702
16 June 2022
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7478287
7 February 2022
Construction Oversight · Administrative Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7392128
29 September 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7327115
28 July 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7279056
15 April 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7176026
17 December 2020
COI Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7108828
10 November 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7092808
28 July 2020
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7018482
16 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6978124
1 May 2020
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6901857
3 April 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6939039
13 January 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6911618
30 August 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6808925
8 April 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6658344
13 March 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6659682
9 October 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6575515
13 August 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6524545
24 July 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6503457
8 March 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6398328
5 July 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6201125
30 May 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6189331
3 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6116580
25 October 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6030658
22 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5915819
18 December 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5784453
25 September 2015
COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5728941
3 September 2015
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5233964
28 October 2014
Annual Inspection · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5067992
9 October 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5002389
30 May 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4874545
5 June 2012
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4335036
7 December 2010
COI Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3898155
12 March 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3704871
22 February 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3683840
30 March 2009
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3480918
2 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3123834
25 October 2007
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3086716
12 June 2007
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2961307
12 October 2006
Re-Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2800843
29 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2762970
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 8 April 2019
Resolved
Each launching appliance must be fitted with brakes that meet the following requirement: The brakes must be capable of stopping the descent of the rescue boat and holding it securely. The brake for the rescue boat did not stop the descent.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 29 April 2019
Resolution: Received report from Norsafe clearing deficiency showing that brake was serviced by recognized servicing company.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 April 2019
Resolved
Each corridor bulkhead in an accomodation must be an A class or B class bulkhead. The A class door in PAM C has a broken closure device.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 9 April 2019
Resolution: Fixed on location.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 8 March 2018
Resolved
Each lifeboat must be a fire protected lifeboat approved under series 160.035. Installed air system pressure was low in both boats, LB1 18mpa w/refill required at 18mpa. Regulator discharge pressure was .7mpa with max discharge pressure as per the manual at .4mpa. LB2 regulator at .5mpa vs. .4mpa. bottle pressure was 3 at 2500psi and 1 at 2100psi when max is 2900 with refill at 2750psi. *3rd party servicing report was one month old and values on report were below minimum. 46CFR108.520 and 33CFR146.15.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2018
Resolved 6 April 2018
Resolution: OIM provided statement of completion.
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 8 March 2018
Resolved
Each unit must carry at least one rescue boat. Each rescue boat must be approved under series 160.156. The emergency equipment provided, regardless of whether or not required by this subchapter shall be maintained in good condition at all times. Trick wheel on FRB is cracked. FRP on port gunwale of FRB is cracked and in need of repair by an authorized repair facility or representative. 46CFR108.560 and 33CFR146.15.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2018
Resolved 6 April 2018
Resolution: Documentation from the OIM.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 25 October 2016
Resolved
L/B#1 SECOND STARTING BATTERY INOP, BATTERY COMPARTMENT HAD STANDING LIQUID (NOT sealed), AND OIL IN BILGE. [LSA Code 4.4.6.2 via 46 CFR 160.135-5(d) ; 46 CFR 160.135-7 (b)(8) ; 33 CFR 146.15 (a)]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 1 November 2016
Resolution: Lifeboat has been started everyday for 5 days on both batteries. Locking bar placed on switch so accidental flip of switch not possible. Oil drained from bilge. New screws and gasket installed on battery compartment.
Operations/Management › Drills/Instruction › Fire
Issued 25 October 2016
Resolved
ON BOARD TRAINING - PERSONNEL W/ DESIGNATED RESPONSIBILITY FOR SURVIVAL OF OTHERS MUST BE INSTRUCTED IN FF EQUIPMENT. FIRE TEAM MEMBERS UNFAMILIAR W/ SCBA AND NOT RECEIVED ON BOARD TRAINING. [33 CFR 146.125 (a) and (b)]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 1 November 2016
Resolution: Training provided by B/S to firefighters on SCBA. Roster list provided.
Electrical › Electrical Distribution System (service) › Cable
Issued 29 September 2015
Resolved
Methanol cable run on spar deck is corroded. Repair or replace to original condition.
Condition: Improper/Lack of Maintenance
Due 6 October 2015
Resolved 29 September 2015
Resolution: Corrected on spot.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 September 2015
Resolved
Handle on junction box in hazardous location is broken. Repair replace to original condition.
Condition: Damaged By Earlier Event
Due 6 October 2015
Resolved 29 September 2015
Resolution: Corrected on spot.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 October 2014
Resolved
The roll-down shutter did not close when tested for fail-safe closing (removal of the thermal link to simulate melting of the link in a fire scenario where the shutter may not have been closed manually). Make necessary adjustments and prove proper operation of the roll-down shutter. Cite 46 CFR 108.135 & 137.
Due 7 November 2014
Resolved 4 November 2014
Resolution: Received documentation showing satisfactory completion.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 October 2014
Resolved
Openings in rated fire boundaries to retain boundary integrity in case of fire. Observed dishpans below roll-down fire shutter for the Scullery on several occasions/after explaining to keep area clear. Items would prevent full closure of the shutter in case of thermal release. Ensure areas in the path of the shutter remain clear at all times. Cite 46 CFR 108.135 & 137.
Due 7 November 2014
Resolved 4 November 2014
Resolution: Received documentation showing satisfactory completion.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 29 October 2014
Resolved
Observed numerous Multi-Cable Transits (MCT's) that had been disturbed to run new cables but were not restored to retain boundary integrity. Affected MCT's were located in the following spaces in the accommodations. Restore integrity of all IAW manufacturer's instructions. Cite 46 CFR 108.133. See AN 5067992 narrative for listing of affected MCT's.
Due 12 March 2015
Resolved 21 February 2015
Resolution: Documentation was provided showing satisfactory correction of all listed MCT discrepancies.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 29 October 2014
Resolved
Documentation was not provided to show satisfactory completion of crane 5-year proof load tests IAW 46 CFR 107.260 for both cranes. Provide documentation for review that satisfies the requirements of 46 CFR 107.260. Noted numerous 3rd Party Tests, but testing is to be witnessed by one of the recognized organizations. Cite 46 CFR 107.260.
Action required: 705 - Other - as specified
Resolved 3 November 2014
Resolution: Weight tests witnessed by ABS with documentation provided for review.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 7 December 2010
Resolved
Obtain verification from Omnipure that relocation of book cell on Omnipure skid to relocate all non-conductive piping outside of hazardous location radius, will not void USCG type approval of the unit. Send documentation of ABS approval of solution per ABS outstanding comment 53 of annual machinery survey #4 dated 30 OCT 09.
Action required: 705 - Other - as specified
Resolved 28 February 2011
Resolution: Skid completely moved from Haz location. ABS surveyor [name withheld] attended.
Documentation › Logs/Records › Logbook (official)
Issued 7 December 2010
Resolved
Provide documentation of close-out for outstanding callouts from annual 3rd party fire-fighting survey/report.
Action required: 705 - Other - as specified
Resolved 28 February 2011
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 25 October 2007
Resolved
02 air supply bottles in #2 life boat were empty and need to be filled or replaced.
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 26 October 2007