MAURY USCG vessel records
← All vessels

SALAMANCA FPU

SALAMANCA FPU is a 2007 industrial vessel. The Coast Guard has recorded 9 inspections since 2016, most recently in July 2026, along with 3 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2026. Most recent: inspection, 15 July 2026.

Built
2007
Last inspected
15 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 July 2026
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WQEJ344
732295
Flag
UNITED STATES
Maury page id
psix-732295

Documentation record

Tonnage as PSIX records it23650 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

15 July 2026 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8439073
2 February 2026 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8305492
19 December 2025 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8285626
26 August 2024 COI Inspection · Construction Oversight · Administrative Inspection
Physical examination · Outer Continental Shelf National Center of Expertise · Activity 8015914
8 June 2021 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7219319
25 April 2017 Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6133978
18 May 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5862999
5 April 2016 COE-Administrative
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5847606
21 March 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5837287

Deficiency record · 3

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2025 No resolution recorded
Provide bilge pumps capable of reliable operation from control room, without restrictions to piping design flow from each watertight compartment in hull. By 31 July 2025; Extended to 30Apr2026 on 28Nov2025.
Action required: 705 - Other - as specified
Due 31 July 2025 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Fire
Issued 18 May 2016 Resolved
Multiple shortcomings: recovery of casualties, intenral comms, donning of FF outfit, establishing boundaries. Conduct on board training to improve planning, continginencies, and attack of fire to satisfaction of marine inspector. 33 CFR 146.125(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 26 May 2016
Resolution: Conducted training.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 18 May 2016 Resolved
Galley door near serving line does not latch; no tag. Replace door. Other galley doors have UL rating, no CG/SFP test tag. Prove doors meet regs or replace doors w/ doors IAW regs. [46 CFR 108.135]
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 23 July 2016
Resolution: Door replaced. Pictures provided.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.