MAURY USCG vessel records Sign in
← All vessels

SALAMANCA FPU

SALAMANCA FPU is a 2007 industrial vessel. The Coast Guard has recorded 23 inspections since 2005, most recently in July 2026, along with 16 deficiencies — 1 with no resolution recorded —.

Records from 2005 to 2026. Most recent: inspection, 15 July 2026.

Built
2007
Last inspected
15 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WQEJ344
732295
Flag
UNITED STATES
—
Maury page id
psix-732295

Inspections, by type

…past their stated due date1
Years with a record 13 calendar years (2005–2026)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it23650 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

15 July 2026 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8439073
2 February 2026 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8305492
19 December 2025 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8285626
26 August 2024 COI Inspection · Construction Oversight · Administrative Inspection
Physical examination · Outer Continental Shelf National Center of Expertise · Activity 8015914
8 June 2021 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7219319
25 April 2017 Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6133978
18 May 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5862999
5 April 2016 COE-Administrative
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5847606
21 March 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5837287
6 March 2014 Deficiency Check · Hull Examination · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4811350
6 July 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4369975
27 May 2012 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4350974
4 May 2012 Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4301958
1 August 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4103974
7 July 2011 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4120357
2 March 2009 Annual Inspection · MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3440079
27 August 2008 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3310179
10 April 2008 In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3181079
17 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3132079
12 October 2007 MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3089309
20 February 2007 Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2877204
6 September 2005 Construction Oversight
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2587359
10 January 2005 Construction Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2678033

Deficiency record · 16

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2025 No resolution recorded
Provide bilge pumps capable of reliable operation from control room, without restrictions to piping design flow from each watertight compartment in hull. By 31 July 2025; Extended to 30Apr2026 on 28Nov2025.
Action required: 705 - Other - as specified
Due 31 July 2025 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Fire
Issued 18 May 2016 Resolved
Multiple shortcomings: recovery of casualties, intenral comms, donning of FF outfit, establishing boundaries. Conduct on board training to improve planning, continginencies, and attack of fire to satisfaction of marine inspector. 33 CFR 146.125(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 26 May 2016
Resolution: Conducted training.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 18 May 2016 Resolved
Galley door near serving line does not latch; no tag. Replace door. Other galley doors have UL rating, no CG/SFP test tag. Prove doors meet regs or replace doors w/ doors IAW regs. [46 CFR 108.135]
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 23 July 2016
Resolution: Door replaced. Pictures provided.
Lifesaving › Launching Appliances › Release Mechanism
Issued 6 March 2014 Resolved
During the brake test for the davit the boat hung up on the retainer chain for the safety pins. The hang up caused the boat to lay over at a 45 degree angle putting a load on the release hook outside the norm. Request the unit perform a load test on the release gear hooks and have the disassembled to ensure proper operation prior to use. A stand by boat is ordered until the boat is operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 June 2014
Resolution: Received email from [name withheld] with 3rd party certification attesting to the full operation of both release gear hooks on Lifeboat A. Boat has been placed back in full service and standby boat has been released.
Communications › Alarms/Indicators › General Alarm
Issued 6 March 2014 Resolved
Red flashing lights in high noise areas were not installed during the construction of the vessel. Unit is to provide a plan to install lights in the required areas or a letter from a professional engineer stating that they are not needed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 22 August 2014
Resolution: Received email from [name withheld] (Compliance) attesting to the plan to install 04 class1 div 1 lights in the high noise areas. The plan is to have the lights installed before the end of the year and we will be informed when it is complete.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 4 May 2012 Resolved
There is no fixed CO2 system for the rental genset install per ABS 10-82 project # MC2067749. Engine is greater than 1,000bhp. Vessel to contact vendor or ABS to resolve issue.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 9 August 2013
Resolution: Hurricane Generator now has a fixed CO2 suppression system installed.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 4 May 2012 Resolved
Provide a Approved Ops Manual or submit to OCMI for approval.
Action required: 705 - Other - as specified
Due 9 June 2012
Resolved 15 May 2012
Resolution: Received Ops Manual from Anadarko, manual is under review.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 7 July 2011 Resolved
Make repairs or replace air hoses as needed to restore to manufacturers specifications in Lifeboat "C".
Action required: 705 - Other - as specified
Due 21 July 2011
Resolved 9 July 2011
Resolution: leaking air line replaced
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 January 2007 Resolved
Demonstrate compliance with 46 CFR 111.105-33 for all electrical installations in hazardous locations to the satisfaction of attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 25 May 2007
Resolution: Cleared by ABS
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 25 January 2007 Resolved
Demonstrate fire protection system for helicopter landing deck is capable of discharging from each hose at 100 PSI prior to helicopter fueling operations.
Action required: 705 - Other - as specified
Resolved 25 May 2007
Resolution: Cleared by ABS
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 January 2007 Resolved
Demonstrate man-overboard drill with fast rescue craft to the satisfaction of attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 25 May 2007
Resolution: No fast rescue craft on board. conducted drill using designated life boat.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 25 January 2007 Resolved
Make all air receivers available for inspection and provide all information and access required by attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 25 May 2007
Resolution: U1A new recievers
Operations/Management › Cargo Transfer/Lightering › Conducted IAW with Facility Operations Manual
Issued 25 January 2007 Resolved
Demonstrate compliance with 46 CFR 58.60 and 46 CFR 111.107 for all industrial systems to the satisfaction of attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 25 May 2007
Resolution: Cleared by ABS
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 25 January 2007 Resolved
Obtain approval of Operating Manual and Construction Portfolio prior to COI.
Action required: 705 - Other - as specified
Resolved 25 May 2007
Resolution: OPS Manual ABS approved
Operations/Management › Drills/Instruction › Abandon Ship
Issued 25 January 2007 Resolved
Obtain USCG approval of Emergency Evacuation plan (EEP) IAW 33 CFR 146.140 prior to COI.
Action required: 705 - Other - as specified
Resolved 26 January 2007
Operations/Management › Drills/Instruction › Activating General Alarm
Issued 25 January 2007 Resolved
Once offshore and operating all machinery/equipment, demonstrate that the general alarm signal produces minimum sound pressure levels above ambient noise levels as required by 46 CFR 113.25-12 and 46 CFR 113.50-15 for public address system prior to COI.
Action required: 705 - Other - as specified
Resolved 22 July 2008

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.