MAURY USCG vessel records Sign in
← All vessels

GATUN

GATUN is a unclassified. The Coast Guard has recorded 7 inspections since 2004, most recently in March 2007, along with 21 deficiencies and 5 operational controls.

Records from 2004 to 2007. Most recent: inspection, 17 March 2007.

Built
Not recorded
Last inspected
17 March 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7015262 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
732476
Flag
PANAMA
—
Maury page id
psix-732476

Inspections, by type

…with no type recorded4
Years with a record 3 calendar years (2004–2007)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it1076 - Simplified, Net Ton
3241 - Simplified, Gross Ton
3241 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

17 March 2007 Type not recorded
No type recorded · USCGC SHERMAN (WHEC 720) · Activity 3298252
9 May 2005 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2353216
8 April 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2332953
25 March 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2319796
21 January 2005 STCW 95 Exam · PI Safety Exam · ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2274325
20 December 2004 Ballast Water Examination · ISPS II Exam · PI Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2262820
14 December 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2269925

Deficiency record · 21

Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 27 December 2004 Resolved
Warning statement missing on turning circle diagram as required on manuvering fact sheet. 33 C.F.R. 164.35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2005
Resolved 27 December 2004
Stability › Watertight Integrity › General
Issued 27 December 2004 Resolved
Provide proof that required drydock surveys were carried out.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2004
Lifesaving › Lifebuoys › Not on Board
Issued 27 December 2004 Resolved
Lifebuoys placed on bridge wings were not the proper weighted type capable of pulling the smoke signal from its station. SOLAS 74/78 Chapter III, regulation 7.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 December 2004 Resolved
Bridge lifebuoy lines were found to be dry-rotted. SOLAS 74/78 Chapter III, regulation 20.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2004
Lifesaving › Lifebuoys › Quantity
Issued 21 December 2004 Resolved
Vessel does not have enough lifebuoys (16 onboard) to meet indicated requirements according to Safety Equipment Certificate (26 reguired). SOLAS 74/78, chapter III, regulation 7.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 January 2005
Resolved 27 December 2004
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 21 December 2004 Resolved
Maneuvering fact sheet was not posted on the bridge. 33 C.F.R. 164.35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2004
Resolved 27 December 2004
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 21 December 2004 Resolved
Steering block diagram not posted on bridge. 33 C.F.R. 164.35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2004
Resolved 27 December 2004
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 21 December 2004 Resolved
Numerous life jackets missing required lights. SOLAS 74/78 Chapter III, regulation 32.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2004
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 21 December 2004 Resolved
Fire alarm panel on bridge indicated 4 areas of "trouble", however alarm signal was being over-rided by silencing; when questioned, the crew did not indicate any knowledge of trouble or concern over the panel's alarm signals. SOLAS 60 Chapter II, regulation 61.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 December 2004 Resolved
Exposed dead end wires found in radio and steering room. SOLAS Chapter 60, Chapter II, regulation 27.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2004
Resolved 27 December 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 21 December 2004 Resolved
Protective covers on fluoresent lights missing from numerous light fixtures in steering and engine spaces. SOLAS 60 chapter II, regulation 27.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2004
Resolved 27 December 2004
Construction/Loadline › Markings › Load Line Mark
Issued 21 December 2004 Resolved
Deck reference line not painted in contrasting color. ILLC 66, Annex I/8.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2004
Resolved 27 December 2004
Lifesaving › Lifeboat Equipment › Radio (fixed two-way VHF radio-telephone)
Issued 21 December 2004 Resolved
Inadequate number of required lifeboat radios and backup batteries for lifeboat radios. Only 2 radios were onboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2004
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 20 December 2004 Resolved
The emergency fire pump was inoperable. SOLAS 60, Chapter II, Regulation 65
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2004
Resolution: Item cleared by class
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 20 December 2004 Resolved
The vessel does not have a ship specific ballast water managment (BWM) plan; BMW reporting book is outdated with old version of report; Vessel failed to submit BWM report to SERC. Vessel's Master and crew unaware of reporting and recordkeeping requirements.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 December 2004
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 20 December 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2004
Resolution: Item cleared
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 20 December 2004 Resolved
The vessel hospital space was being used for storage. ILO-147/PWSA 33 USC 1233 (b)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2004
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 December 2004 Resolved
The self closing door located within the superstructure to engine space failed to close properly. SOLAS 60, chapter II, regulation 38.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2004
Resolution: Item cleared by class
Fire Fighting › Firemans Outfit › Lantern (Electric Safety Lamp)
Issued 20 December 2004 Resolved
Flashlights and fireproof safety line missing from firemen's outfits. SOLAS 60, Chapter II, regulation 63.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2004
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 20 December 2004 Resolved
SOPEP missing approval letter/stamp. SOPEP missing U,.S. contact numbers and current owner/operator information. MARPOL 73/78 annex I/26
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Resolved 21 December 2004
Resolution: Item cleared
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 20 December 2004 Resolved
Safety managment system not implemented properly as indicated by the numerous and varied deficiencies identified during the inspection. ISM audit required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2004
Resolution: ISM audit was conducted on December 28th with 6 non-conformities issued by class.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.