MAURY USCG vessel records
← All vessels

SC 4233 BP

SC 4233 BP is a 2003 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in May 2026, along with 16 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 6 May 2026.

Built
2003
Last inspected
6 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

732490
Flag
UNITED STATES
Maury page id
psix-732490

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it3 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

6 May 2026 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8368152
24 February 2025 Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8083481
1 May 2024 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7904873
8 February 2023 Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7629203
10 May 2022 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7448537
20 April 2021 Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7179226
12 March 2020 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6925960
15 February 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6626623
6 February 2019 Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6626611
16 February 2018 COI Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6351346
3 April 2017 DAPI Audit · Hull Examination · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6116860
22 August 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5980062
7 July 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5931619

Deficiency record · 16

10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 May 2026 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible. Vessel did not have charts for intended voyage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 11 June 2026
Resolution: Image well received. ALL SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2026 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Port navigation light was blocked and failed to provide ark of visibility.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 11 June 2026
Resolution: Image well received. ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 May 2026 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Vessel was missing 1 flashlight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 11 June 2026
Resolution: Image well received. ALL SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 February 2025 Resolved
If a State issues validation stickers, its numbering system must contain the requirements that stickers must be displayed within 6 inches of the number and the stickers must meet the requirements in paragraphs (b) and (c) of this section. Missing current state registration sticker.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2025
Resolved 26 February 2025
Resolution: New sticker placed on the vessel
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 February 2025 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2025
Resolved 26 February 2025
Resolution: Replaced battery
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 24 February 2025 Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs. O/O did not have current proof of chemical testing enrollment
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2025
Resolved 26 February 2025
Resolution: Proof was provided that employees were enrolled in DAPI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 February 2025 Resolved
Rails must be permanently installed except that the following rails may be removable; (1) Rails in way of embarkation stations and boarding locations. missing one of the embarkation courses
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2025
Resolved 26 February 2025
Resolution: missing course installed
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 24 February 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. marking wasn't legible
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2025
Resolved 18 March 2025
Resolution: new labels were installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 February 2025 Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. ground strap missing
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2025
Resolved 26 February 2025
Resolution: replaced grounding strap
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 February 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: (a) Operation of the main propulsion machinery both ahead and astern. The outboard engine was not available for testing due to a suspected electrical problem.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2023
Resolved 17 February 2023
Resolution: Received third party report showing repairs made to the engines and tested.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 February 2023 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: (i) Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. The annual maintenance was not conducted for the portable fire extinguishers by the owner or qualified third party.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2023
Resolved 17 February 2023
Resolution: Received third party report for fire extinguisher servicing.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 28 April 2021 Resolved
The manning requirements for a particular vessel are determined by the OCMI after consideration of the applicable laws, the regulations in this part, and all other factors involved, such as: emergency situations, size and type of vessel, installed equipment, etc. Crew CPR/First Aid Certification expired. 46 CFR 15.501
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 27 May 2021
Resolution: Crew attended and completed CPR/First Aid course.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 March 2020 Resolved
Show proper operation of dashboard gauges.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2020
Resolution: New gauges were placed in service.
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 July 2016 Resolved
Update Coast Pilot
Due 7 August 2016
Resolved 22 August 2016
Navigation › Piloting/Steering › Marine Charts
Issued 7 July 2016 Resolved
Update/correct marine chart
Due 7 August 2016
Resolved 22 August 2016
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 July 2016 Resolved
Renew wasted handle on port emergency fuel shutoff.
Due 7 August 2016
Resolved 22 August 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.