MAURY USCG vessel records Sign in
← All vessels

FRISIA ROTTERDAM

FRISIA ROTTERDAM is a 2004 freight ship. The Coast Guard has recorded 15 inspections since 2004, most recently in August 2014, along with 5 deficiencies and 2 operational controls.

Records from 2004 to 2014. Most recent: operational control imposed, 18 August 2014.

Built
2004
Last inspected
18 August 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9299032 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
732806
Flag
GIBRALTAR
—
Maury page id
psix-732806

Inspections, by type

…with no type recorded7
Years with a record 6 calendar years (2004–2014)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12538 - Convention (Subpart B), Net Ton
25406 - Convention (Subpart B), Gross Ton
33781 - Dead Weight, Ton
44541 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

18 August 2014 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4958731
26 November 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3369929
20 October 2008 Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3348036
3 June 2008 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3226188
11 July 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2992610
18 April 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2910319
28 March 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2896573
16 July 2006 ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2714163
15 July 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2713765
16 February 2006 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2586473
3 September 2005 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2482348
16 March 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2311779
23 December 2004 ISPS II Exam · PII Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2263940
22 December 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2263671
18 December 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2261679

Deficiency record · 5

Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 20 October 2008 Resolved
Chief Engineer does not have Flag State endorsements or proof of application. Vessels Safe Manning Certificate requires one Chief Engineer. Vessel must provide documentation stating that the Chief Engineer has an interim Flag State endorsement or accepted application. SOLAS IX, Reg 1; ISM A/6 to The Satisfaction of Flag State and Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2008
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 20 October 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 November 2008
Resolution: Received flag endorsements from vessel.
Electrical › Electric Generation Source (emergency) › Switch
Issued 20 October 2008 Resolved
The emergency generator starts inadvertently without powerloss. Due to this the Crew leaves the emergency generator in 'manual' position with disables the required auto start function. A crew member is stationed at the emergency generator when entering/departing port as a safety precaution. Spare parts have been ordered and company has been notified. SOLAS II-1/43.3. To the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 November 2008
Resolution: Received class report attesting to proper operation of emergency generator.
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 March 2007 Resolved
CLASS SOCIETY SURVEYOR TO ATTEST A PROPER ARRANGEMENT OF RELAY SWITCH FROM EMERGENCY BUS TO MAIN SWITCH BOARD.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2007
Resolved 28 March 2007
Resolution: Received class report that stated that the vessels temporary operating procedure to effectively operate the electrical breaker satisfactory during maneuvering periods until no later than 28 April 2007.
Construction/Loadline › Structures › Trunk
Issued 23 December 2004 Resolved
The hatch to the Bosun Storage is bent, due to voyage damage, and no longer weathertight. Make permanent repairs to the satisfaction of Class by 23 JAN 05.
Action required: 705 - Other - as specified
Due 23 January 2005
Resolved 16 March 2005
Resolution: CLASS REPORT

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.