MAURY USCG vessel records Sign in
← All vessels

MICHELANGELO TRADER

MICHELANGELO TRADER is a 2004 freight ship. The Coast Guard has recorded 52 inspections since 2004, most recently in February 2023, along with 17 deficiencies and 16 operational controls.

Records from 2004 to 2023. Most recent: operational control imposed, 13 February 2023.

Built
2004
Last inspected
13 February 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9282170 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA4850
733170
Flag
MALTA
—
Maury page id
psix-733170

Inspections, by type

…with no type recorded24
Years with a record 14 calendar years (2004–2023)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9528 - Convention (Subpart B), Gross Ton
4703 - Convention (Subpart B), Net Ton
17757 - Displacement, Ton
12914 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

13 February 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7635821
3 February 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7631630
27 January 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7627910
5 January 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7616665
10 December 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7366180
9 December 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7365254
21 January 2020 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6892231
2 April 2019 Ballast Water Examination · In-Service Inspection · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6654424
13 June 2014 ISPS II Exam · PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4887716
27 July 2012 COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4392471
25 June 2012 COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4358477
7 June 2012 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4336432
21 May 2012 COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4317993
1 February 2012 COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4236268
3 January 2012 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4216364
22 August 2011 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4118668
20 August 2011 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4121778
8 July 2011 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4073987
10 January 2011 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3921383
27 November 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3899299
11 November 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3889338
18 October 2010 COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3871921
27 September 2010 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3855565
27 September 2010 COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3857867
22 March 2010 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3700950
21 March 2010 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3699646
9 February 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3676990
29 December 2009 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3655796
28 December 2009 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3655800
12 May 2009 ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3472960
20 April 2009 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3457134
17 April 2009 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3454886
28 April 2008 PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3194332
7 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3160006
6 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3159516
1 February 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3141283
29 December 2007 Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 3122203
23 November 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 3102989
29 May 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2945598
27 April 2007 PII Safety Exam · Deficiency Check · MARPOL Annex I Examination · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2916194
24 August 2006 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2758020
18 April 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2627194
4 January 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2560986
29 October 2005 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2526599
10 August 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2458232
18 July 2005 In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2430706
19 May 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2362176
8 April 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2329177
18 January 2005 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2276682
11 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2272469
30 December 2004 ISPS II Exam · PII Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2266526
30 December 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2266654

Deficiency record · 17

03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 9 December 2021 Resolved
All hatchways … shall be weathertight and fitted with gaskets and clamping devices. PSCOs observed approximately 25 feet of cargo hold gasket material on the deck from forward hatch cover 3A. ICLL 88 Annex I / Reg. 16(1)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 11 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 December 2021 Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least A-0 class divisions and be protected by self-closing doors at all levels. PSCOs observed multiple A Class boundary doors on the main ladder unable to self close. 74SOLAS(01) II-2/46.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 January 2023
Resolution: Vessel rectified the deficiency by havign the door self-close
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 December 2021 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. PSCOs discovered multiple self closing doors held open with ropes. 74SOLAS(01) II-2/47.2
Action required: 10 - Deficiency Rectified
Resolved 10 December 2021
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 2 April 2019 Resolved
Any ship 400 GRT and above but less than 10,000 GRT shall be fitted with oil filtering equipment complying with paragraph 6 of this regulation... shall ensure that any oily mixture has an oil content not exceeding 15 PPM. Vessel reported a malfunction of the oil content meter during operational test of the oily water separator. MARPOL ANNEX I/14.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2019
Resolved 21 January 2020
Resolution: The vessel provided documentation it has an operational oil content meter.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 June 2014 Resolved
0650 - Not less than one half of the total number of lifebouys shall be provided with lifebuoy self-igniting lights complying with the requirements of paragraph 2.1.2. of the code. 03 self-igniting lights were not operational; located aft starboard, aft port, and amidships port side. 74 SOLAS (04 Cons.) CH III Reg. 7.1.3.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 13 June 2014
Resolution: Vessel crew immediately replaced with extra bouys kept in storage.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 June 2014 Resolved
1730 - Oil Filtering Equipment shall be of a design approved by the administration and shall ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. Chief Engineer was unable to successfully demonstrate operational test of OWS. Marpol Annex I, Reg. 14.6.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2014
Resolution: Witnessed satisfactory demonstration of the OWS.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 13 June 2014 Resolved
0615 - Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 minutes. Vessel's rescue boat unable to start due to an inoperable fuel hand pump. 74 SOLAS (09 Cons.) CH III, Reg. 14.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2014
Resolution: Witnessed satisfactory starting of the rescue boat engine.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 June 2014 Resolved
0710 - Doors required to be self-closing shall not be fitted with hold-back hooks. A-60 fire door at entrance to galley is fitted with hold-back hook. Fire control plan states galley door to be self-closing. 74 SOLAS (04 Cons.) CH II-2, Reg. 4.4.2.2.
Action required: 705 - Other - as specified
Due 27 June 2014
Resolved 8 July 2014
Resolution: 7July14: Received photos from vessel validating that hold back hooks have been removed for galley doors.
Construction/Loadline › Structures › Door
Issued 8 June 2012 Resolved
ICLL 66 Ch II/Reg 12.1 All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel and weathertight when closed. Wastage on sheet metal on interior of CO2 room door indicates lack of weathertightness.
Action required: 705 - Other - as specified
Due 12 July 2012
Resolved 31 July 2012
Resolution: Vessel renewed the steel on the interior of the CO2 door.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 June 2012 Resolved
74SOLAS(01) CH III/Reg 7.1.3 LSA II/2.1.2 Not less than half of the total number of lifebuoys shall be provided with self-igniting lights. 02 self igniting lights on the stbd side (aft and midships) do not light.
Due 8 June 2012
Resolved 8 June 2012
Resolution: Corrected on the spot.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 8 June 2012 Resolved
74SOLAS(01) Ch II-1/Reg 26.1 The machinery shall be of a design and construction adequate for the service for which intended. Forward winches (port and stbd) are leaking oil from the seals.
Action required: 705 - Other - as specified
Due 12 July 2012
Resolved 31 July 2012
Resolution: [name withheld]. replaced the packing inside both winches. The crew also had pictures of said procedure.
Fire Fighting › Fire Hoses › Location
Issued 7 June 2012 Resolved
74SOLAS(01) II-2/Reg 21. Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. Hoses from fire stations 14 and 15 were being used to transfer fresh water.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 July 2012
Resolved 31 July 2012
Resolution: Vessel ordered fresh water hoses that are marked and used only for fresh water.
Communications › Radio Communications › EPIRB
Issued 27 April 2007 Resolved
EPIRB hydrostatic release is specified for liferafts only
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2007
Resolved 27 April 2007
Resolution: Received receipt for proper EPIRB type hydrostatic release purchase
Fire Fighting › Fire Pumps › Pressure
Issued 27 April 2007 Resolved
Emergency fire pump will not provide adequate pressure to fight a fire. Water appears to trickle out of the hose.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2007
Resolved 27 April 2007
Resolution: Deficiency corrected on the spot. Pressure was achieved due to opening a closed valve
Lifesaving › Rescue Boat › Propulsion Engine
Issued 27 April 2007 Resolved
Rescue boat motor will not start. It is unknown why the motor wont start
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2007
Resolved 27 April 2007
Resolution: Received receipt for the purchase of new rescue boat motor and written statement from C/E that motor was successfully installed and operational
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 30 December 2004 Resolved
Forward bulkhead of aux. generator room is "A" Class boundary. Bulkhead has vent installed without any means to make boundary "A" Class.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 18 January 2005
Resolution: Received Class report from Lloyds Register showing that item #1 has been corrected and that fire dampener has been installed in the forward bulkhead vent, in generator space.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 30 December 2004 Resolved
Doors leading to open deck must be locked or unlocked using key on either side. If door is locked from inside and key is left in keyway, door may not be unlocked from outside, this installation is to be approved by the Flag Administration or install thumb knobs on the inside.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 18 January 2005
Resolution: Received statement from flag administration for item #2, that the door locks are being installed which will allow easier emergency egress out of interior of the ship.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.