MAURY USCG vessel records Sign in
← All vessels

AGIOS NIKOLAS

AGIOS NIKOLAS is a 2004 freight ship. The Coast Guard has recorded 23 inspections since 2005, most recently in August 2021, along with 6 deficiencies and 3 operational controls.

Records from 2005 to 2021. Most recent: inspection, 29 August 2021.

Built
2004
Last inspected
29 August 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9291779 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
733764
Flag
GREECE
—
Maury page id
psix-733764

Inspections, by type

…with no type recorded7
Years with a record 11 calendar years (2005–2021)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it39818 - Convention (Subpart B), Gross Ton
25830 - Convention (Subpart B), Net Ton
86791 - Displacement, Metric Ton
76390 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

29 August 2021 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7290992
14 January 2021 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7124460
12 January 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7117336
24 June 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6985509
15 April 2020 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6935911
22 October 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6561564
26 August 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6251923
17 August 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6233507
3 February 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4230598
9 November 2010 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3887776
2 November 2010 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3920542
1 December 2009 Damage Survey · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3638356
7 July 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3253500
24 September 2007 ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3064732
17 May 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2932804
26 July 2006 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2726434
21 January 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2570839
10 February 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2290533
10 February 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2297626
13 January 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2273409
10 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2272488
10 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2307355
3 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2268360

Deficiency record · 6

08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 12 January 2021 Resolved
The detection system shall initiate audible and visual slarms distinct in both repects from the alarms of any other system not indicating fire, in sufficient places to ensure that the alarms are heard and observed on the navigation bridge and by a responsible engineer officer. PSCO noted that the visual alarms in the engine room were not activating. Code 1020, Fire Alarms, SOLAS(14)II-2/7.4.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2021
Resolution: Received Class and Tech reports attesting to proper system operation and completed repairs.
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 February 2012 Resolved
0710-Fire prevention-Fire protection systems, fire-fighting systems and appliances shall be maintained ready for use. The quick-closing fuel shutoff valve on the heavy fuel oil service tank was blocked in the open position with a wooden plug.-SOLAS 2009 cons. II-2/14.2
Action required: 705 - Other - as specified
Due 3 February 2012
Resolved 4 February 2012
Resolution: Received class report from LR stating that all Quick closing valves were now tested in Engine Room, especially the Heavy Fuel Oil Quick Closing Valve, and found satisfactory.
Fire Fighting › Fire Main › Condition
Issued 3 February 2012 Resolved
0725-Fixed fire extinguishing installation-The condition of the ship and its equipment shall remain fit to proceed to sea without danger to the ship or persons on board. There is a minor hole on the fire main in the forward bosun's store.-SOLAS 2009 cons. I/11
Action required: 705 - Other - as specified
Due 17 February 2012
Resolved 7 February 2012
Resolution: Received class report from LR stating that complete pipe renewed satisfactorily. Pressure test carried out on the Fire line found satisfactory.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 9 November 2010 Resolved
Liquid hydrostatic testing of bunkering arrangements is to be conducted annually. Vessel has not conducted test of one and a half the Maximum Allowable Working Pressure since 6 NOV 2009.
Action required: 705 - Other - as specified
Due 9 December 2010
Resolved 13 December 2010
Resolution: 13NOV2010 Received Onboard Testing Certificate from M/V AGIOS NIKOLAS attesting for the proper liquid test of the Fuel Oil and Diesel Oil Transfer Pipeline.
Communications › Alarms/Indicators › High Water Alarm
Issued 9 November 2010 Resolved
Water ingress alarms when the water level reaches (.5) meters and (2) meters alarm for #4 Cargo Hold (2) meters alarm is sounding on the bridge. No water is present in the hold.
Action required: 705 - Other - as specified
Due 16 November 2010
Resolved 13 November 2010
Resolution: 13NOV2010 Received Class report attesting for proper repairs to the water ingress alarm on the #4 Cargo Hold, see scanned survey statement.
Construction/Loadline › Hull › Hull Plating
Issued 1 December 2009 Resolved
Master of the M/V AGIOS NIKOLAS stated port side bow area struck dock upon mooring at this berth at ADM Grain in Corpus Christi, TX.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2009
Resolved 1 December 2009
Resolution: Recieved class report stating that the damage to the bow area is considered minor and not affecting seaworthiness. No repair is necessary and vessel is considered in class and safe to proceed.

Ownership record