Records from 2017 to 2023. Most recent: inspection, 11 September 2023.
Inspection history · 26
11 September 2023
Appeal
Administrative · Commandant (CG-CVC) · Activity 7789375
21 July 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7748146
6 July 2023
PSC B · Deficiency Check · Appeal · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7724562
12 August 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7531556
10 July 2022
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7499733
8 December 2021
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7363249
30 May 2021
Ballast Water Examination · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7209046
15 November 2020
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7093671
10 June 2020
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6972858
22 May 2020
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6958073
16 May 2020
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6954121
10 May 2020
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6950434
10 May 2020
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6951064
27 October 2019
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6839804
10 May 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6680099
20 April 2019
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6664317
21 March 2019
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6646528
18 March 2019
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6644734
18 October 2018
PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6560467
28 November 2017
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6314574
22 November 2017
ISPS III Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6311333
14 November 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6306695
10 July 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6204119
27 April 2017
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6133530
11 March 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6103047
3 March 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam · COE-Dockside
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6096098
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 July 2023
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory.
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause, if known.
PSCO’s observed two inoperable fire pumps and insufficient quantity of water to the fire main from emergency fire pump. PSCO’s observed fire doors that couldn’t self-close and hatchways in position 2 that weren’t weathertight. An ISM audit is required prior to departure.
74 SOLAS (20) IX/3.1
ISM Code Part A/10.1
ISM Code Part A/10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 July 2023
Resolution: Vessel replaced both fire pumps, fixed the emergency fire pump, and replaced the gaskets for the doors and hatches.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 July 2023
Resolved
The required fire pumps shall be capable of delivering for fire-fighting purposes a quantity of water, at the pressure specified in paragraph 4.
PSCO’s observed the required fire pumps were unable to deliver the quantity of water at the pressure specified in paragraph 4. The water pressure appeared visibly low, and the vessel’s crew was unable to provide a means of testing to verify adequate water pressure was being delivered.
74 SOLAS (97 Cons.) CH. II-2 Reg 4.2.1.2
Action required: 30 - Ship detained
Resolved 21 July 2023
Resolution: PSCO's observed both fire pumps provided adequate pressure of 5.5 bar.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 July 2023
Resolved
Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times.
A condition of class was issued to allow the vessel to utilize the general service and ballast pumps for firefighting purposes due to the vessel having two inoperable fire main pumps. PSCOs observed the valve responsible for directing the water to the fire main was stuck in position, disabling the delivery of water.
74SOLAS (97Cons.) CH II-2 Reg 21
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 27 July 2023
Resolution: Vessel sent video of fire pump mechanical seal not leaking. All Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 6 July 2023
Resolved
At positions 1 and 2 the height above the deck of hatchway coamings fitted with weathertight hatch covers of steel or other equivalent material shall be fitted withgaskets and clamping devices that shall be at as specified in Regulation 15 (1).
PSCO’s observed the hatchway between the emergency steering room and the main deck was not weathertight and allowed light to shine though when sealed.
ICLL 66/88
Annex I/Reg 16(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: Chief engineer replaced the gasket and the hatchway is now weather tight
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 July 2023
Resolved
… Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing.
PSCOs observed the door between the Engine Control Room and Engine Room was unable to self-close. PSCO also, observed the door between the main deck and engine room was also unable to self-close, compromising the required fire boundary.
74 SOLAS (97Cons.) CH II-2 Reg 47.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: Chief engineer adjusted the door spring. Door is now able to self close.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 July 2023
Resolved
All external openings leading to compartments assumed intact in the damage analysis, which are below the final damage waterline, are required to be watertight.
PSCO’s observed the door leading down to forward CO2 room was not able to be sealed watertight due gasket excessively worn.
The inability for the door to properly seal compromised the weathertight integrity
74 SOLAS (97Cons.) Reg 25-10.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: Chief engineer replaced the gasket. Door is now watertight.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 July 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on deck. The shutoff valve from the section side of the diesel oil purifier does not work by remote activation; however, the diesel oil purifier is not in use. The suction valve will remain out of service and tagged. 74SOLAS(20)I/11; Code 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2022
Resolved 12 August 2022
Resolution: Recived documentation form RO stating a new Quick closing valve had been installed on the 09th of August 2022 and tested/working satisfactory. Documentation attached.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 July 2022
Resolved
Class A fire doors shall be possible to be opened and closed from each side of the bulkhead by one person only. The door extending from the main space to the ECR did not open as intended. 74SOLAS(97)II-2/30.3; Code 10c issued.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 July 2022
Resolved 10 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2020
Resolved
2 lifebuoys shall be capable of quick release from the navigation bridge. The quick release lifebuoys are installed in a position where they will fall on the deck of the ship upon activation. 74SOLAS(97) III/ 7.1.3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2020
Resolved 4 June 2020
Resolution: Life buoys relocated and brought into compliance. Class/flag notified and approved of corrective actions.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 10 May 2020
Resolved
A HAZMAT employee must recieve the training required by this subpart at least once every 3 years. The 2nd officer's HAZMAT training has expired beyond 3 years. 49 CFR 172.704
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2020
Resolved 22 May 2020
Resolution: RECIEVED DOCUMENTATION FROM THE VESSEL THAT THE 2ND OFFICER HAS COMPLETED HAZMAT TRAINING IAW 49CFR172.704 DOCUMENTATION UPLOADED INTO THIS ACTIVITY.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 May 2020
Resolved
No person may use transfer pipe system that has not been tested to 1.5 times the maximum allowable working pressure on an annual basis. Vessel has gone over a year without a bunkering piping test.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 May 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 May 2020
Resolved
Each vessel must have a warning statement of conditions on the manuevering information fact sheet. The warning statement is not displayed in the wheelhouse. 33 CFR 164.35
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 10 May 2020
Resolution: Warning statement added to fact sheet before exam ended.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 April 2019
Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without sanction of the administration.
The second means of starting the EDG, via spring, was inoperable. Vessel will swap batteries for second means of starting the EDG until repairs have been made.
SOLAS (2014) CH I/Reg. 11(b).
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2019
Resolved 16 May 2019
Resolution: Received picture and RO report attesting to satisfactory correction.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 18 October 2018
Resolved
A self contained energy source of electrical power shall be provided. The emergency source of power onboard the vessel is currently inoperable. 74 SOLAS (1997) CH II-1/REG 43.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2018
Resolved 20 October 2018
Resolution: Received report from vessel's RO stating that the vessel has an alternative means of providing power from an emergency power source.
Pollution Prevention/Response › Prevention Equipment › Garbage Grinder/Comminuter
Issued 22 November 2017
Resolved
2120 - Disc vharge of food wastes shall be comminuted or ground and shall be capable of passingb through a screen with opening no greater than 25MM. Vessel is discharging ungrounded food wastge into the sea. MARPOL ANNEX V/4.2 17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2017
Resolution: Recieved Flag Letter attesteing correction for the Garbage Management Plan and for the discharging of food.
Electrical › Electric Generation Source (emergency) › Generator
Issued 14 November 2017
Resolved
1430 - Auxiliary Engines - Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration with a stored energy capacity of at least three consecutive starts. A second means shall be provided with an additional three consecutive starts.
74 SOLAS 2004 CONS CH II-1/REG 44
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 20 November 2017
Resolution: Vessel replaced all batteries and replaced the "Spring Starter", which was the secondary means for the starting arrangement. The emergency generator is now fully operational.
IBS Class Surveyor Report is included in the Documents.
Fire Fighting › Fire Pumps › Arrangement
Issued 14 November 2017
Resolved
0740 - Pumps - In Cargo Ships of 2000 gross tonnage and upwards, if a fire in any one compartment could put all the pumps out of action there shall be an alternative means consisting of a fixed independently driven emergency pump which shall be capable of supplying two jets of water.
74 SOLAS 1997 CONS CH II-1/REG 4.3.3.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 20 November 2017
Resolution: Vessel replaced the fire pump with a Desmi model. PSCO's witnessed a operational test along with IBS Class surveyor of the fire pump. Emergency Fire pump is fully operational.
IBS Class Surveyor Report is included in the Documents
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 November 2017
Resolved
0725 - Fixes Fire Extinguishing installation - Maintenance shall be carried out based on the guidelines developed by the organization. Vessel's Fixed CO2 Firefighting System is out of date on servicing.
74 SOLAS 2014 CONS CHII-2/REG14.2.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 28 November 2017
Resolution: Vessel serviced fixed CO2 system and provided documentation to USCG
Deck/Cargo › Cargo Stowage › General
Issued 14 November 2017
Resolved
1199 - Other (Cargo) - The Cargo Securing Manual shall be approved by the administration in accordance with IMO MSC.1/CIRC. 1353/ REV. 1. The cargo securing manual is not approved by the Administration.
74 SOLAS 2014 CONS CHVI/REG 5.6
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 20 November 2017
Resolution: IBS Class surveyor issued a Cargo Securing Manual approval ltr.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 14 November 2017
Resolved
2550 - Maintenance of Ship & Equipment - Recommend external ISM Audit after objective evidence was found for lack of maintenance to vessel's systems and equipment, to include vessel's emergency generator, emergency pump, and CO2 fixed firefighting system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2017
Resolved 20 November 2017
Resolution: Ships management and IBS Class surveyor completed a ISM Audit of the vessel's maintenance program and procedures. Class findings are attached in the activity. MSD Port Canaveral is satisfied with the findings.
Electrical › Electric Generation Source (service) › Generator
Issued 3 March 2017
Resolved
The ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship remains fit to proceed to sea without danger to the ship or persons onboard. Vessel lost control of the main engine due to the loss of electrical power.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2017
Resolved 4 March 2017
Resolution: Recieved Class report attesting to the proper operation of the ships propulsion and generators.