MAURY USCG vessel records Sign in
← All vessels

BOOMVANG SPAR

BOOMVANG SPAR is a 2002 industrial vessel. The Coast Guard has recorded 37 inspections since 2001, most recently in April 2026, along with 16 deficiencies.

Records from 2001 to 2026. Most recent: inspection, 23 April 2026.

Built
2002
Last inspected
23 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-7342

Inspections, by type

…with no type recorded4
Years with a record 20 calendar years (2001–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 37

23 April 2026 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8354600
4 December 2025 Annual Inspection · Administrative Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8280353
10 August 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7765574
16 September 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7560360
2 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7527890
21 June 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7482782
24 September 2021 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7321345
26 January 2021 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7131798
11 September 2020 Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7061174
20 August 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7038084
12 August 2019 In-Service Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6782344
1 August 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6794912
19 September 2018 In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6544696
9 September 2018 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6619590
4 September 2017 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6264997
31 May 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6161902
5 July 2016 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6021107
28 June 2016 Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5925755
21 October 2015 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5755816
27 August 2015 Annual Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5228435
22 March 2010 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3700464
28 April 2009 Examination of Repairs · In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3493637
14 April 2008 Annual Inspection · In-Service Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3186285
10 May 2007 COI Inspection · Internal Structural Exam · In-Service Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3186291
7 May 2007 In-Service Inspection · COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2921110
26 August 2005 Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3186309
7 August 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2242231
3 August 2004 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2154997
15 June 2004 In-Service Inspection · Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2096200
24 March 2004 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2030465
27 February 2004 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2016657
10 December 2003 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1968846
22 October 2003 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1933862
25 July 2003 In-Service Inspection · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1945805
10 May 2002 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1651992
6 December 2001 Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382459
30 August 2001 Type not recorded
No type recorded · Activities Europe · Activity 1384695

Deficiency record · 16

Lifesaving › Lifeboat › Exhaust Pipe
Issued 28 June 2016 Resolved
Exhaust was found to be excessively leaking into cabin under exhaust wrapping. Exhaust pipe had large crack in it.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 3 July 2016
Resolution: Replaced lifeboat.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 August 2015 Resolved
All exterior A-60 doors from temporary living quarters will not self close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 21 October 2015
Resolution: Temp living quarters exterior doors have been replaced with new doors.
Electrical › Electric Generation Source (service) › Generator
Issued 28 April 2009 Resolved
Generator windings shorted out and the generator was sent in for repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 28 May 2009
Resolution: Attended the vessel and witnessed satisfactory test of the generator.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 14 April 2008 Resolved
Provide amended contact sheet for the SPAR EEP for review
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 May 2008
Resolution: Received e-mail document with updated contact list. Contacted 24 HR POC. Contact successful new numbers accurate.
Lifesaving › Lifeboat › Fender
Issued 14 April 2008 Resolved
Complete repairs to damaged rub rails on both lifeboat where they ride on steel guides into the hawsed position.
Condition: Damaged By Earlier Event
Due 20 May 2008
Resolved 12 May 2008
Resolution: OIM provided photographic evidence of proper repairs.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 14 April 2008 Resolved
Repair or renew malfunctioning 30sec time delay on the MCC CO2 system.
Condition: Damaged By Earlier Event
Due 20 May 2008
Resolved 18 April 2008
Resolution: Received verification from 3rd party fire fighting systems technician that the unit had been replaced and tested.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 10 May 2007 Resolved
Renew partially partesd main line cable on the platform's 60 ton crane and load test to the satisfaction of the attending CG inspector or Class Surveyor
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2007
Resolution: New cable insalled and weight test witnessed by ABS surveyor [name withheld]
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 10 May 2007 Resolved
Complete repairs to and provide a tecnicians report attesting to the proper operation of the breathing air system regulatos in both life boats.
Condition: Unknown
Due 18 May 2007
Resolved 18 May 2007
Resolution: Servicing company renewed regulators.
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 26 August 2005 Resolved
Complete proper installation of cable through MCT in tool room external A-60 bulkhead.
Condition: Improper Installation
Due 2 September 2005
Resolved 2 September 2005
Resolution: OIM provided verification of repair VIA photos.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 26 August 2005 Resolved
Provide and maintain purge air to electrical enclosure as required for installations in hazardous locations
Condition: Improper/Lack of Maintenance
Due 26 August 2005
Resolved 26 August 2005
Resolution: Operator immediately opened purge air for cabinet. OIM held conference with the on hitch crew and passed information to B hitch crew to always maintain purge air.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 15 June 2004 Resolved
Properly install pipe run through boundry on emergecy generator room.
Condition: Improper Installation
Due 14 July 2004
Resolved 20 July 2004
Resolution: Letter of Fact received.
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 15 June 2004 Resolved
Small hot water tanks leaking all over the deck requiring the tank to be sequired. Renew or replace so hot water can be provided fro the crew. Boomvang had the new tanks on order.
Due 14 July 2004
Resolved 4 July 2004
Resolution: Letter received stating completions
Lifesaving › Lifeboat › Markings
Issued 15 June 2004 Resolved
Install Life boat instructions at life area.
Condition: Unknown
Due 14 July 2004
Resolved 29 June 2004
Resolution: Received letter state the posting of the instructions.
Fire Fighting › Fixed Deck Foam System › Monitors
Issued 27 February 2004 Resolved
Helideck has refueling capability. Provide approved foam system for the helideck. 46 CFR 108.487
Due 27 May 2004
Resolved 10 May 2007
Resolution: [name withheld] verified installation of the helideck foam sprinkler system IAW approved plans. Witnessed a satisfactory foam and coverage test.
Fire Fighting › Automatic Sprinkler System › Piping
Issued 10 May 2002 Resolved
Prior to production activities, prove proper operation of deluge system to attending ABS surveyor.
Due 30 May 2002
Resolved 10 May 2002
Lifesaving › Rescue Boat › Propulsion Transmission
Issued 10 May 2002 Resolved
Prove proper operation of Fast Rescue Craft (FRC).
Due 10 May 2002
Resolved 10 May 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.