MAURY USCG vessel records Sign in
← All vessels

STEEL HONESTY

STEEL HONESTY is a 2000 freight ship. The Coast Guard has recorded 13 inspections since 2000, most recently in March 2016, along with 6 deficiencies and 3 operational controls.

Records from 2000 to 2016. Most recent: inspection, 3 March 2016.

Built
2000
Last inspected
3 March 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9198393 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
BAHAMAS, THE
—
Maury page id
psix-7344

Inspections, by type

…with no type recorded7
Years with a record 6 calendar years (2000–2016)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it26010 - Convention (Subpart B), Gross Ton
14834 - Convention (Subpart B), Net Ton
53181 - Displacement, Metric Ton
45578 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

3 March 2016 PII Safety Exam · MARPOL Annex VI Survey · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5826193
2 March 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5825854
1 March 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5821445
19 November 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3366153
8 February 2008 Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3134956
30 May 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2664653
6 September 2005 MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2481273
26 November 2004 NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2248114
22 November 2004 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2246165
28 January 2004 MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1995373
26 January 2004 Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 1993443
22 January 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1991415
8 October 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 282700

Deficiency record · 6

Documentation › Certificates/Documents
Issued 28 January 2004 Resolved
Master produced All Annex Documents to the Class Certificate but the Class certificate was missing. Must provide (IAW SOLAS 74/78 Chapt 1 Regulation 6) before departing Pier 86 Seattle to satisfaction of USCG. LEGACY COMPONENT DESC: Classification Document
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2004
Resolved 29 January 2004
Resolution: Class came on board and issued temporary provision to class document, b/c Master could not find the original.
Navigation › Piloting/Steering
Issued 28 January 2004 Resolved
Gyrocompass is OOC as noted in Letter of Deviation #04-04 issued by this port. Vessel must show proper operation of gyrocompass (IAW with 33 CFR 164.35) and provide a copy of the tech report to USCG satisfaction. LEGACY COMPONENT DESC: Gyro Compass
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2004
Resolved 29 January 2004
Resolution: Technician fixed gyrocompass and provided report. Satisfactory operation verified by USCG.
Fire Fighting › Firemans Outfit
Issued 28 January 2004 Resolved
Fire suit had excessive wear and was delaminating. Required to replace suit, and have two readily available for USCG Inspection (IAW SOLAS 74/78 Chapt II-2 Regulation 17, 1.1) prior to departing Pier 86 Seattle, WA LEGACY COMPONENT DESC: Protective Clothing
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2004
Resolved 29 January 2004
Resolution: Damaged fire suit was replaced with new one, as verified by USCG. Damaged suit will be taken out of service but used as a training aid.
Fire Fighting › Miscellaneous Items
Issued 28 January 2004 Resolved
Crew did not show proficiency in general fire fighting. Communications between team leader and fire team were inadequate and crew took little action to combat fire. Little familiarity with equipment and duties. Fire doors and dampers unsecured ; limited familiarity in emergency fire pump operation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2004
Resolved 29 January 2004
Resolution: Satisfactory Fire Drill was conducted in the Galley verified by Class representative and USCG. Emergency fire pump was energized quickly and effectively.
Lifesaving › Buoyant Smoke Signals
Issued 28 January 2004 Resolved
Smoke signal punctured due to weather during transit. Bridge wing (port) life buoy smoke marker must be replaced and verified by USCG. SOLAS 74/78 III-19.2
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2004
Resolved 29 January 2004
Resolution: Old Bracket was removed. Vessel obtained hot work permit to weld on new bracket and proper installation of smoke signal was verified.
Lifesaving › Lifebuoys
Issued 28 January 2004 Resolved
Life buoys on both port and starboard lifeboat decks have no access to the self igniting light b/c the latches of the holders for the lights are corroded shut. Must free holders to the satisfaction of USCG. SOLAS 74/78 III-19.2 LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2004
Resolved 29 January 2004
Resolution: Corrosion was sanded down and repainted. Light Signal Holders were found to be operational.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.