JASMINE S is a 2004 tank ship. The Coast Guard has recorded 12 inspections since 2005, most recently in April 2024, along with 9 deficiencies and 4 operational controls.
Records from 2005 to 2024. Most recent: inspection, 28 April 2024.
- Built
- 2004
- Last inspected
- 28 April 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9279721 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FGX7
734683
Flag
PANAMA
—
Maury page id
psix-734683
Inspections, by type
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it28150 - Convention (Subpart B), Gross Ton
11553 - Convention (Subpart B), Net Ton
28150 - Simplified, Gross Ton
11553 - Simplified, Net Ton
54780 - Displacement, Metric Ton
45937 - Dead Weight, Metric Ton
11553 - Convention (Subpart B), Net Ton
28150 - Simplified, Gross Ton
11553 - Simplified, Net Ton
54780 - Displacement, Metric Ton
45937 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
28 April 2024
Administrative Inspection · PSC B · Deficiency Check · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7893311
9 September 2022
Bulk Liquid Transfer Monitor
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7554760
8 September 2022
PSC B · COC-TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7552111
23 September 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3331079
22 September 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3329458
22 September 2008
ISPS I Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3330161
4 February 2008
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3141404
20 December 2007
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3118542
7 March 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2305313
19 January 2005
Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 2278595
14 January 2005
Ballast Water Examination · COC-TVE Renew · ISPS I Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2275124
12 January 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2273491
Deficiency record · 9
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 28 April 2024
Resolved
Tankers shall be equipped with at least one portable instrument for measuring oxygen and one for measuring flammable vapor concentrations, together with a sufficient set of spares. Suitable means shall be provided for the calibration of such instruments. One of the portable gas detectors is not operable and the other is not able to be calibrated.
74SOLAS2001 II-2/59.5
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 April 2024
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The port lifeboat is not able to turn to starboard.
74SOLAS2020 III/20.1
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 28 April 2024
Resolved
The venting system shall be provided with devices to prevent the passage of flames into the cargo tanks. 25% of the vessels Flame Screens are covered in oil and connot operate as intended.
74SOLAS2001 II-2/59.1.5
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 April 2024
Resolved
ANy Fixed Fire Detection shall be capabale of immediate operation at all times. The smoke detector above the generator is inoperable.
74SOLAS2001 II-2/13.1.1
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other cargo/timber/deck/construction
Issued 28 April 2024
Resolved
The last 1 meter of vapor piping must be painted in the sequence red/yellow/red. The starboard manifolds vapor piping is not painted.
46CFR39.2001(h)
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 8 September 2022
Resolved
Oil tankers of 150 gross tonnage and above shall be equipped with an oil discharge monitoring and control system approved by the administration. Crew could no prove proper operation of the oil discharge monitoring system under simulation. Prior to carrying cargorequiring the use of the ODM system, prove proper operation to the satisfaction of the CG.
MARPOL ANNEX I/Reg 31.1
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 September 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed holes in the weld in the bulkhead was cut and repaired during the IGG equipment replacement in 2021
SOLAS 2020(Cons) Ch.I/Reg 11(a)
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 20 December 2007
Resolved
vessel is required to have pumproom inspection with marine chemist at next U.S. port due to lack of available marine chemist at SEC DelBay.
Engineering › Steering Gear System › Pump
Issued 20 December 2007
Resolved
Audible and visual alarms for low hydraulic level shall be given on navigation bridge. Alarm failed to activate during testing.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.