MAURY USCG vessel records
← All vessels

JASMINE S

JASMINE S is a 2004 tank ship. The Coast Guard has recorded 3 inspections since 2022, most recently in April 2024, along with 7 deficiencies.

Records from 2022 to 2024. Most recent: inspection, 28 April 2024.

Built
2004
Last inspected
28 April 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 April 2024
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2022–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9279721
734683
Flag
PANAMA
Maury page id
psix-734683

Documentation record

Tonnage as PSIX records it28150 - Convention (Subpart B), Gross Ton
11553 - Convention (Subpart B), Net Ton
28150 - Simplified, Gross Ton
11553 - Simplified, Net Ton
54780 - Displacement, Metric Ton
45937 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

28 April 2024 Administrative Inspection · PSC B · Deficiency Check · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7893311
9 September 2022 Bulk Liquid Transfer Monitor
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7554760
8 September 2022 PSC B · COC-TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7552111

Deficiency record · 7

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 28 April 2024 Resolved
Tankers shall be equipped with at least one portable instrument for measuring oxygen and one for measuring flammable vapor concentrations, together with a sufficient set of spares. Suitable means shall be provided for the calibration of such instruments. One of the portable gas detectors is not operable and the other is not able to be calibrated. 74SOLAS2001 II-2/59.5
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2024
Resolved 29 April 2024
Resolution: Vessel received two new portable gas detectors and training on use and calibration. PSCO verified proper operation and crew competency with the new gas detectors via satisfactory calibration and function checks of both new detectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 April 2024 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The port lifeboat is not able to turn to starboard. 74SOLAS2020 III/20.1
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2024
Resolved 28 April 2024
Resolution: Ships crew repaired steering prior to PSCO departure.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 28 April 2024 Resolved
The venting system shall be provided with devices to prevent the passage of flames into the cargo tanks. 25% of the vessels Flame Screens are covered in oil and connot operate as intended. 74SOLAS2001 II-2/59.1.5
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2024
Resolved 29 April 2024
Resolution: Vessels crew cleaned or replaced the dirty flame screens.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 April 2024 Resolved
ANy Fixed Fire Detection shall be capabale of immediate operation at all times. The smoke detector above the generator is inoperable. 74SOLAS2001 II-2/13.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2024
Resolved 2 May 2024
Resolution: Received Class Report stating smoke detector was replaced and satisfactorily tested.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other cargo/timber/deck/construction
Issued 28 April 2024 Resolved
The last 1 meter of vapor piping must be painted in the sequence red/yellow/red. The starboard manifolds vapor piping is not painted. 46CFR39.2001(h)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 April 2024
Resolved 29 April 2024
Resolution: Vessels crew painted the vapor mainold in the sequence Red/Yellow/Red.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 8 September 2022 Resolved
Oil tankers of 150 gross tonnage and above shall be equipped with an oil discharge monitoring and control system approved by the administration. Crew could no prove proper operation of the oil discharge monitoring system under simulation. Prior to carrying cargorequiring the use of the ODM system, prove proper operation to the satisfaction of the CG. MARPOL ANNEX I/Reg 31.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 September 2022
Resolved 8 September 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 September 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed holes in the weld in the bulkhead was cut and repaired during the IGG equipment replacement in 2021 SOLAS 2020(Cons) Ch.I/Reg 11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 October 2022
Resolved 29 April 2024
Resolution: Recieved Class Report attesting to the repairs of the welds.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.