TOWER BRIDGE is a 2004 tank ship. The Coast Guard has recorded 38 inspections since 2005, most recently in April 2020, along with 18 deficiencies and 13 operational controls.

Records from 2005 to 2020. Most recent: inspection, 21 April 2020.

Built
2004
Last inspected
21 April 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9292034 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
734934
Flag
LIBERIA
—
Maury page id
psix-734934

Inspections, by type

…with no type recorded17
Years with a record 11 calendar years (2005–2020)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it27725 - Convention (Subpart B), Gross Ton
13762 - Convention (Subpart B), Net Ton
47252 - Dead Weight, Ton
57054 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

21 April 2020 PSC B · COC-TVE Renew
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6940450
19 December 2018 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6598938
18 November 2017 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6309789
13 November 2017 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6306129
9 November 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6304377
5 May 2017 COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6139410
29 April 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6135085
24 January 2017 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6080885
25 November 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6047550
18 November 2016 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6039618
11 June 2014 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4886137
11 June 2014 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4886184
16 March 2014 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4813226
12 June 2012 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4341555
9 January 2012 Deficiency Check · Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4221232
8 January 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4217142
4 January 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4218030
3 April 2009 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3445670
29 March 2009 COC-TVE Renew · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3442088
30 December 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3386441
26 May 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3214528
26 April 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3192780
31 March 2008 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3174710
20 February 2008 COC-TVE Annual · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3140078
20 February 2008 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3150714
15 November 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3098915
26 April 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2920769
22 February 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2876124
9 February 2007 COC-TVE Renew · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2867022
5 October 2006 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2794138
19 May 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2653326
16 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2650878
24 January 2006 COC-TVE Annual · Random ISPS/MTSA/PSC · MARPOL Annex II Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2572073
7 November 2005 MARPOL Annex I Examination · Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2529872
8 March 2005 Deficiency Check · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2305942
22 January 2005 COC-TVE Renew · ISPS II Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2275117
22 January 2005 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2281062
20 January 2005 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2280476

Deficiency record · 18

Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 18 November 2017 Resolved
The tank high level alarm required by paragraph (A) of this section must be identified by the legend "high-level alarm" in black letters at least 50.8 millimeters (2inches) high on a white background.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 November 2017
Resolved 23 November 2017
Resolution: Vessel provided adequate documentation to show deficiency rectified and painted correctly in black.
Documentation › Certificates/Documents › IOPP Certificate
Issued 18 November 2016 Resolved
Vessel's IOPP Form B states that the deadweight tonnage is 47.199 but the vessel's actual deadweight tonnage is 47.252 in accordance with the statement form the shipyard. MARPOL ANNEX I / REG 7.2
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 December 2016
Resolved 25 November 2016
Resolution: Recieved official letter from Class determining what the vessel's official deadweight tonnage. Attached to MISLE Activity #6047550
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 18 November 2016 Resolved
Prior to performing any physical change or change in metod of operation that results in an increase in emissions, the applicant shall submit a Notice Of Intent (NOI) to the administrator through the EPA regional office. Master was not aware of nor did he send the NOI 40CFR 55.4 40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 November 2016
Resolved 25 November 2016
Resolution: Vessel provided eNOI.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 11 June 2014 Resolved
THE VESSEL TOWER BRIDGE SUBMITTED THIER NOTICE OF ARRIVAL AFTER ARRIVING AT THE ANCHORAGE FOR THE PORT OF CORPUS CHRISTI. THIS WAS DISCOVERED WHEN THE VESSEL WAS BEING VETTED BY THE ARRIVALS BRANCH.
Action required: 705 - Other - as specified
Resolved 11 June 2014
Resolution: VESSEL WAS HELD OUT OF PORT UNTIL FOR 24 HOURS FROM THE TIME THEY SUBMITTED THEIR NOTICE OF ARRIVAL.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 January 2012 Resolved
1720-Found additional piping on OWS connected to 02 safety valves, piping not approved by class society or part of manufacturer design. Arrangement could allow for potential bypass of filtering process. Class shall attest to piping arrangment & functionality of the valves installed after discharge pump & on top of OWS. This piping connects to oil discharge line after 3 way valve.17 a c MARPOL 14.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2012
Resolution: 10 JAN 2012 Recieved class report NYK 1200009 attesting to the piping and new approved drawings. Seals have also been placed on safety valves.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 9 January 2012 Resolved
2535-The vessels safety management system does not adequately address the testing of LEL for ballast tanks that are partially filled with water. There are no procedures in place or policies addressing when and how crewmembers will test the ballast tanks. 09 SOLAS IX REG 3 ISM CODE 7 Prior to next U.S port to the satisfcation of Administration.
Action required: 15 - Rectify deficiencies by next port
Resolved 12 June 2012
Resolution: Received, reviewed and accepted report from SCF Unicom and copies of SMS approved pages modifed to correct deficiencies to address the testing of LEL for ballast tanks that are partially filled.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 9 January 2012 Resolved
1835- PV valves: 1Starboard, 2 Starboard, 3 Starboard, and 5 Starboard did not have vacuum valve reseat properly upon testing, creating potential for an explosive atmosphere.
Action required: 705 - Other - as specified
Resolved 9 January 2012
Resolution: Vessel was able to reseat the valves properly.
Engineering › Generator (propulsion/auxiliary-electric) › Cable
Issued 9 January 2012 Resolved
1499 -The emergency generator fuel shut off was found to be inoperable for cutting off fuel flow. 2004 SOLAS II-2 Reg 4.2.2.3.4
Action required: 705 - Other - as specified
Resolved 9 January 2012
Resolution: Vessel corrected deficiency and provided temporary means of shutting fuel source off.
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 January 2012 Resolved
0710-Quick Closing valves are being held open by alternate devices creating fire hazard. 09SOLAS II-2 REG 14 2.1.2
Action required: 705 - Other - as specified
Resolved 9 January 2012
Resolution: All devices were removed.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 29 March 2009 Resolved
Vsl high level and overfill cargo level alarms (visual only) are not functioning. Repair the same, prior to conducting cargo operations in the United States (loading of cargo) to the satisfaction of class. 46 CFR 39.20-7(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2009
Resolution: Corrected, received LR faxed class report # MMI 940034 dated 4/2/09.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 20 February 2008 Resolved
NOTED THAT THE INERT GAS SYSTEM DECK WATER SEAL PIPING IS HOLED. (SEE PHOTOS THIS CASE) MAKE REPAIRS TO THE PIPING TO THE SATISFACTION (EITHER TEMPORARY OR PERMANENT) OF THE CLASSIFICATION SOCIETY PRIOR TO DEPARTURE FROM ST. CROIX. WHILE REPAIRS ARE BEING MADE, THE VESSEL IS PROHIBITED FROM CARGO OPERATIONS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 22 January 2005 Resolved
No record of transfer equipment testing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2005
Resolution: Received report that Cargo Piping system has been hydraulically tested with p=15 kg/cm2. Cargo Piping tested for tanks and lines numbers 5p, 3st, 3p, 2p/st, 1p/st, slop p/st. Tested on 17 Nov 2004
Deck/Cargo › Cargo Stowage › General
Issued 22 January 2005 Resolved
Cargo tanks not maintained below 8% 02
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2005
Resolution: Started up inert gas system
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 22 January 2005 Resolved
No audible cargo over flow alarm not operable
Action required: 15 - Rectify deficiencies by next port
Resolved 22 January 2005
Electrical › Electric Generation Source (emergency) › Generator Cable
Issued 22 January 2005 Resolved
Fuel shut off frozen / pulley
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2005
Resolution: de-iced pulley system
Electrical › Electric Generation Source (emergency) › Switch
Issued 22 January 2005 Resolved
Emergency generator secondary means of starting is not operable
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2005
Resolution: deficiency corrected to satisfaction of Coast Guard Inspector
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 January 2005 Resolved
Ventilation into emergency generator space cannot be secured; space contains a fixed Gas Fire Extinguishing System.
Action required: 705 - Other - as specified
Due 22 February 2005
Resolved 8 March 2005
Resolution: Received class report from Lloyd’s Register satisfying requirement.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 22 January 2005 Resolved
Fire extinguisher was not properly secured to the bulkhead
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2005
Resolution: secured fire extinguisher bracket to the bulkhead

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.