Records from 2004 to 2010. Most recent: inspection, 23 March 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
23 March 2010
COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3701098
5 July 2009
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 3557414
16 March 2009
Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3435247
29 January 2009
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3401942
20 October 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3353855
24 March 2008
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3170600
15 March 2007
Periodic Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2889145
20 March 2006
Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2606127
16 July 2004
Inclining Experiment · Hull Examination · Construction Oversight · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2135239
Electrical › Electric Generation Source (service) › Generator
Issued 9 April 2010
Resolved
Priming pump on STBD generator set was leaking.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 9 April 2010
Resolution: Vessel removed pump and installed new pump in presence of marine inspectors.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 March 2010
Resolved
Provide updated charts and pubs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2010
Resolved 13 April 2010
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 March 2010
Resolved
Provide hailing port on all ring bouys.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 25 March 2010
Resolution: Ring bouys properly marked.
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 23 March 2010
Resolved
Wrap exhaust can. (inspection conducted 3/23 and 3/25, initial visit lagging missing on center can and found doubler, follow up visit request lagging removed from pt stbd exhaust cans found numerous doublers).
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 9 April 2010
Resolution: Vessel wrapped exhaust cans and replaced cans where doublers were found.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 23 March 2010
Resolved
Make air received ready for inspection
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 25 March 2010
Resolution: Air receiver examined, satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 23 March 2010
Resolved
Replace exhaust cans prior to commercial operation. Center, port and stbd cans found to have doublers due to internal corrosion.
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 9 April 2010
Resolution: Vessel replaced exhaust cans .
Engineering › Fuel Oil Service System › Valve, Control
Issued 23 March 2010
Resolved
Repair/replace fuel shutoff valve.
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 9 April 2010
Resolution: Vessel repaired shutoff valve. Inspectors tested shutoff valve and cycled through valve.
Lifesaving › Lifefloat › Paddle
Issued 23 March 2010
Resolved
Replace paddles on lifefloats. Paddles cracked and plastic separating from body.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 9 April 2010
Resolution: Vessel replaced all worn and cracked paddles.
Lifesaving › Lifefloat › Lifeline
Issued 16 March 2009
Resolved
Lifelines on life floats were deteriorated
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2009
Resolution: lifelines were replaced
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 24 March 2008
Resolved
Master is to provide certificate for mattresses on board.
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 25 March 2008
Resolution: Master provided documentation.
Navigation › Piloting/Steering › Marine Charts
Issued 24 March 2008
Resolved
Provide current updated charts of local operating area.
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 25 March 2008
Resolution: Provided Charts.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 20 March 2006
Resolved
Provide Voyage Plan for overnight trips.
Action required: 705 - Other - as specified
Resolved 30 May 2006
Communications › Radio Communications › EPIRB
Issued 20 March 2006
Resolved
Install new hydro-release.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2006