MAURY USCG vessel records Sign in
← All vessels

BIG E

BIG E is a 2005 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2004, most recently in March 2010, along with 13 deficiencies.

Records from 2004 to 2010. Most recent: inspection, 23 March 2010.

Built
2005
Last inspected
23 March 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9348871 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC3882
735219
Flag
UNITED STATES
367015730 (licence lapsed)
Maury page id
psix-735219

Inspections, by type

…with no type recorded1
Years with a record 6 calendar years (2004–2010)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
222 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
74 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC3882MMSI 367015730 · expired · compulsorily equipped · granted 3 February 2005, cancelled 11 April 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 9

23 March 2010 COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3701098
5 July 2009 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 3557414
16 March 2009 Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3435247
29 January 2009 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3401942
20 October 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3353855
24 March 2008 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3170600
15 March 2007 Periodic Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2889145
20 March 2006 Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2606127
16 July 2004 Inclining Experiment · Hull Examination · Construction Oversight · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2135239

Deficiency record · 13

Electrical › Electric Generation Source (service) › Generator
Issued 9 April 2010 Resolved
Priming pump on STBD generator set was leaking.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 9 April 2010
Resolution: Vessel removed pump and installed new pump in presence of marine inspectors.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 March 2010 Resolved
Provide updated charts and pubs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2010
Resolved 13 April 2010
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 March 2010 Resolved
Provide hailing port on all ring bouys.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 25 March 2010
Resolution: Ring bouys properly marked.
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 23 March 2010 Resolved
Wrap exhaust can. (inspection conducted 3/23 and 3/25, initial visit lagging missing on center can and found doubler, follow up visit request lagging removed from pt stbd exhaust cans found numerous doublers).
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 9 April 2010
Resolution: Vessel wrapped exhaust cans and replaced cans where doublers were found.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 23 March 2010 Resolved
Make air received ready for inspection
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 25 March 2010
Resolution: Air receiver examined, satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 23 March 2010 Resolved
Replace exhaust cans prior to commercial operation. Center, port and stbd cans found to have doublers due to internal corrosion.
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 9 April 2010
Resolution: Vessel replaced exhaust cans .
Engineering › Fuel Oil Service System › Valve, Control
Issued 23 March 2010 Resolved
Repair/replace fuel shutoff valve.
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 9 April 2010
Resolution: Vessel repaired shutoff valve. Inspectors tested shutoff valve and cycled through valve.
Lifesaving › Lifefloat › Paddle
Issued 23 March 2010 Resolved
Replace paddles on lifefloats. Paddles cracked and plastic separating from body.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 9 April 2010
Resolution: Vessel replaced all worn and cracked paddles.
Lifesaving › Lifefloat › Lifeline
Issued 16 March 2009 Resolved
Lifelines on life floats were deteriorated
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2009
Resolution: lifelines were replaced
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 24 March 2008 Resolved
Master is to provide certificate for mattresses on board.
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 25 March 2008
Resolution: Master provided documentation.
Navigation › Piloting/Steering › Marine Charts
Issued 24 March 2008 Resolved
Provide current updated charts of local operating area.
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 25 March 2008
Resolution: Provided Charts.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 20 March 2006 Resolved
Provide Voyage Plan for overnight trips.
Action required: 705 - Other - as specified
Resolved 30 May 2006
Communications › Radio Communications › EPIRB
Issued 20 March 2006 Resolved
Install new hydro-release.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2006

Ownership record