Records from 2010 to 2025. Most recent: inspection, 6 October 2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 October 2025
Resolved
Inspector Observed 03 high level bildge alarm lights not operating to include the Engine Room, Fuel tank room and the FWD compartment. Vessel to replace lights with ones that work.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 6 October 2025
Resolved
Inspector observed completely faded oil placard card. Vessel should replace with an new legible placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2025
Resolved
Inspector observed cracking on the lifebuoy. Missing correct length of lanyard for the light. Replace lifebuoy and obtain proper line for the light attachment.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 October 2025
Resolved
Inspector observed heavily faded lifejacket donning instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2025
Resolved
Inspector observed no AMP meter on the battery charger.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 October 2025
Resolved
Inspector observed a plastic valve/plug on the port engine fuel filter. Needs to be metallic.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 March 2025
Resolved
Boundaries that spearate machinery spaces from accommodation spaces must be lined with noncombustible panels or insulation. Insulation above starboard engine is loose and hanging down.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 1 April 2025
Resolution: USCG MI verified deficiency has been corrected properly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 March 2025
Resolved
All escape hatches and other emergency exits must be marked on both sides "EMERGENCY EXIT, KEEP CLEAR." Escape hatch not marked.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 1 April 2025
Resolution: USCG MI verified deficiency has been corrected properly.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 March 2025
Resolved
The rules concerning lights (83.20 through 83.31) shall be complies with. Vessels stern light inoperable.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 1 April 2025
Resolution: USCG MI verified deficiency has been corrected properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025
Resolved
At each inspection test pre-engineered fire protection equipment. Green indicating light at operating station for fire protection equipment inoperable.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 1 April 2025
Resolution: USCG MI verified deficiency has been corrected properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 March 2025
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. You failed to have an annual inspection within the 3 months before or after you anniversary date of 30 November 2024.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2025
Resolution: USCG MIs completed a satisfactory Annual Inspection.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 December 2024
Resolved
46 CFR 181.450
Vessels on an oceans route must have interconnected smoke detection and be installed such that the actuation of an alarm in one area results in both audible and visual alarms in all areas.
Vessel does not have any smoke detection. Smoke detection is required in at least the head and the salon.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2025
Resolved 3 January 2025
Resolution: New approved smoke detectors installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 December 2024
Resolved
46 CFR 176.600(a)
Owner shall make vessel available for drydock examinations.
The deck to bulkhead tab in the anchor locker has become delaminated and separated in multiple locations. Submit a repair proposal to this office detailing how the repair shall be conducted. The vessel may complete repairs in or out of the water after receiving approval of the repair plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2025
Resolved 3 January 2025
Resolution: Tab joint repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 22 June 2024
Resolved
Each vessel that operates on the high seas,must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's EPIRB has been lost and must be replaced and mounted in an accetable location to the cognizant Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 22 June 2024
Resolved 26 June 2024
Resolution: Verified new registered EPIRB was installed on vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2024
Resolved
The owner, charterer, managing operator, or master of must keep a correct list of the names of all persons that embark on and disembark from the vessel and the list shall be available to the Coast Guard upon request. Vessel was unable to provide list of crew and passengers to the Coast Guard upon request. Vessel owner must provide Coast with updated process on how passenger lists are recorded and ready upon request.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2024
Resolved 26 June 2024
Resolution: Passenger list with names will be kept by vessel captain and owner ashore for every voyage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2022
Resolved
EACH LIFE JACKET MUST BE MARKED WITH TYPE I RETROOREFLECTIVEV MATERIAL APPRIVED IN 46 CFR 164.018 OR OTHER STANDARD SPECIFIED BY THE COMMANDANT. RETROREFLECTIVE MATERIAL WAS NOT SERVICEABLE. REPALCE RETROREFLECTIVE MATERIAL.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 6 March 2022
Resolution: Photo evidence provided of retrotape, MI verified.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 February 2022
Resolved
AS APPROPRIATE FOR THE INTENDED VOYAGE, A VESSEL MUST CARRY ADEQUATE AND UP-TO-DATE CHARTS, U.S. COAST PILOT COAST GUARD LIGHT LIST, TIDE TABLES AND CURRENT TABLES. PROVIDE NAUTICAL PUBLICATIONS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 6 March 2022
Resolution: Photo evidence provided of publications, MI verified.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 28 February 2022
Resolved
STATIONS IN THE MARITIME SERVICE MUST BE LICENSED BY THE FCC EITHER INDIVIDUALLY OR BY FLEET. MISSING FCC STATION AUTHORIZATION CERTIFICATE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 23 March 2022
Resolution: FCC documents provided and verified by MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 December 2020
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Forward and aft bulkheads in the engine room are not watertight. Seal with approved material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2021
Resolved 8 January 2021
Resolution: Vessel owner provided evidence of proper sealant of the forward and aft bulkhead penetrations in the engine room, meeting the watertight integrity requirement.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 30 November 2020
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel is operated beyond the 20 nautical mile limitation, but not more than 100 nautical miles from the nearest land, and is not equipped with a MF-DSC frequency transmitter. Install proper MF-DSC radio IAW manufacturer's instructions. Until corrected, vessel operations are restricted to 20NM.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 15 December 2020
Resolution: Observed MF-DSC radio installed IAW manufacturer's instruction and an FCC-licensed technician completed a safety certificate examination.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 30 November 2020
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel's VHF-DSC radio is not equipped with a GPS feed which provides full operation of the DSC alert function. Connect GPS feed to the radio via nmea data cable connector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 15 December 2020
Resolution: Observed a new VHF-DSC radio installation IAW manufacturer's instruction and an FCC-licensed technician completed a safety certificate examination.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 November 2020
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel does not have an FCC safety certificate. Ensure an FCC-licensed technician attends the vessel for a detailed inspection of the radio installations on board once every five years, obtain and maintain FCC safety certificate to be kept on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 15 December 2020
Resolution: Verified FCC-licensed technician completed a safety certificate examination, and owner has valid FCC safety certificate onboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 November 2020
Resolved
A pre-engineered fixed gas fire extinguishing system must be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector. Vessel's Fireboy Cintex system was installed with the safety pin still in place; preventing manual activation from outside the space. Master removed red tamper seal and safety pin, and properly stowed the pin.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 December 2020
Resolved 30 November 2020
Resolution: Master removed red tamper seal and safety pin, and properly stowed the pin.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 November 2020
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test and make available for inspection all items in the ship's outfit, such as navigation lights and equipment. Sound signal found to be undersized for vessel length. Provide proper sound signaling device tpo include horn/bell.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 15 December 2020
Resolution: Owner provided sound signal sufficient for vessels up to 65' in length. Owner also provided sufficiently sized 8" bell.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 November 2020
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel is not in compliance with chemical testing program requirements. Provide all applicable employment testing results. 46CFR16.210/16.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 15 December 2020
Resolution: Owner provided all applicable employment testing results, and is in compliance with the DAPI program requirements.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 30 November 2020
Resolved
There must be a means of accurately determining the amount of fuel in each fuel tank either by sounding, through a separate sounding pipe or a fill pipe, or by an installed marine type fuel gauge. Master currently uses vessel draft references to determine fuel tank amount. Operator intends to request special consideration to allow current means of determining fuel level to meet requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 7 January 2021
Resolution: O/O removed the old fuel sending unit to dip the tank with a fuel level measuring dipstick, marked with Full, 3/4, half, and 1/4 full indicating lines, then put the old sending back in to secure the opening on the fuel tank.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 March 2020
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent.
Port vent stuck open.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2020
Resolution: Master provided video of air vent fully functonal.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 March 2020
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection.
Fire extinguisher bracket in foward passenger compartment was broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 11 March 2020
Resolution: Installed new bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Retro tape worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 11 March 2020
Resolution: New retro tape installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2020
Resolved
A vessel must have one or more ring life buoys. Replace retro.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 11 March 2020
Resolution: Retro tape replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 March 2020
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Light at operating station extinguished.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 11 March 2020
Resolution: Video provided of alarm and light fully operational at operating station.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 2 March 2020
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Bilge hose too short.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 2 March 2020
Resolution: Bildge hose mounted properly.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 March 2020
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Hydro static release not properly mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 2 March 2020
Resolution: Master properly instaled hydro static-release.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2020
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Test all employees prior to employment.
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 20 April 2020
Resolution: Employee no longer works for the company. All employees are enrolled in testing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2019
Resolved
Each PFD must have at least 31 square inches of retroflective material on front side and 31 square inches on back sides. Vessel has 2 PFD's which retro tape is wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel replaced old retro with new retro on 02 life jackets
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 February 2019
Resolved
A vessel must have at least three 2.5 gallon buckets with an attached lanyard. Vessel currently has three 5 gallon buckets. Make into 2.5 gallon buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner provided 3 2.5 gallons fire buckets
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 25 February 2019
Resolved
A durable placard must be posted with the emergency broadcast instructions and information, specific to the individual vessel. Vessel does not have placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner provided emergency broadcast instructions placard.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 February 2019
Resolved
Vessel needs a Employee Assistance Program (EAP)which must include at least the following elements: Display and distribution of informational material:display and distribution of a community service hot-line telephone number. Vessel needs to post EAP program.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner provided valid Employee Assistance Program.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 February 2017
Resolved
Ammomia inhalants missing 46 CFR 184.710
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2017
Resolved 28 February 2017
Resolution: Vessel procured new strips
Construction/Loadline › Structures › End Bulkhead
Issued 28 February 2017
Resolved
found open hole in bulkhead fwd stbd side E/R 46 CFR 179.212
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 2 March 2017
Resolution: O/o corrected deficiency by providing marine grade fire stop for e/r penetration.