← All vessels
ENDLESS SUMMER II
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named ENDLESS SUMMER II
ENDLESS SUMMER II is a 2005 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2005, most recently in October 2025, along with 76 deficiencies, 2 operational controls and 1 casualty investigation in 2010.
Records from 2005 to 2025. Most recent: inspection, 6 October 2025.
- Built
- 2005
- Last inspected
- 6 October 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 76 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2010
Identity
1168496
WDC8511
735325
Flag
UNITED STATES
367088490 (licence lapsed)
Maury page id
psix-735325
Inspections, by type
…with no type recorded1
Years with a record
19 calendar years (2005–2025)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)43.0 ft × 16.0 ft × 7.0 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER INT'L BOAT WORKS · FT PIERCE, FL, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portST AUGUSTINE, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 11 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
25 - Simplified, Net Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDC8511MMSI 367088490 · expired · compulsorily equipped · granted 25 November 2015, cancelled 28 March 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 30
6 October 2025
Deficiency Check · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8247283
21 March 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8097408
2 December 2024
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8041981
22 June 2024
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7940080
12 December 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7839582
27 February 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7662747
13 December 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7640717
28 February 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7403241
15 December 2020
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7110173
30 November 2020
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7096901
20 April 2020
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6941336
2 March 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6907993
25 February 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6632037
4 December 2018
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6591805
30 November 2018
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6589740
1 March 2018
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6364212
28 February 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6095882
16 November 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6042056
23 November 2015
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5768534
13 March 2014
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4811680
6 January 2012
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4219672
1 August 2011
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4131957
14 December 2010
COI Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3907849
31 March 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3725415
26 March 2010
Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3703222
17 March 2009
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3435025
8 January 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3126826
5 July 2007
Hull Examination · Deficiency Check · Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2984483
23 January 2006
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2572997
20 January 2005
Construction Oversight · Simplified Stability Test · Initial Certification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2277781
Deficiency record · 76
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 October 2025
Resolved
Inspector Observed 03 high level bildge alarm lights not operating to include the Engine Room, Fuel tank room and the FWD compartment. Vessel to replace lights with ones that work.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 6 October 2025
Resolved
Inspector observed completely faded oil placard card. Vessel should replace with an new legible placard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2025
Resolved
Inspector observed cracking on the lifebuoy. Missing correct length of lanyard for the light. Replace lifebuoy and obtain proper line for the light attachment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 October 2025
Resolved
Inspector observed heavily faded lifejacket donning instructions.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2025
Resolved
Inspector observed no AMP meter on the battery charger.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 October 2025
Resolved
Inspector observed a plastic valve/plug on the port engine fuel filter. Needs to be metallic.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 March 2025
Resolved
Boundaries that spearate machinery spaces from accommodation spaces must be lined with noncombustible panels or insulation. Insulation above starboard engine is loose and hanging down.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 March 2025
Resolved
All escape hatches and other emergency exits must be marked on both sides "EMERGENCY EXIT, KEEP CLEAR." Escape hatch not marked.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 March 2025
Resolved
The rules concerning lights (83.20 through 83.31) shall be complies with. Vessels stern light inoperable.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025
Resolved
At each inspection test pre-engineered fire protection equipment. Green indicating light at operating station for fire protection equipment inoperable.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 March 2025
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. You failed to have an annual inspection within the 3 months before or after you anniversary date of 30 November 2024.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 December 2024
Resolved
46 CFR 181.450
Vessels on an oceans route must have interconnected smoke detection and be installed such that the actuation of an alarm in one area results in both audible and visual alarms in all areas.
Vessel does not have any smoke detection. Smoke detection is required in at least the head and the salon.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 December 2024
Resolved
46 CFR 176.600(a)
Owner shall make vessel available for drydock examinations.
The deck to bulkhead tab in the anchor locker has become delaminated and separated in multiple locations. Submit a repair proposal to this office detailing how the repair shall be conducted. The vessel may complete repairs in or out of the water after receiving approval of the repair plan.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 22 June 2024
Resolved
Each vessel that operates on the high seas,must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's EPIRB has been lost and must be replaced and mounted in an accetable location to the cognizant Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2024
Resolved
The owner, charterer, managing operator, or master of must keep a correct list of the names of all persons that embark on and disembark from the vessel and the list shall be available to the Coast Guard upon request. Vessel was unable to provide list of crew and passengers to the Coast Guard upon request. Vessel owner must provide Coast with updated process on how passenger lists are recorded and ready upon request.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2022
Resolved
EACH LIFE JACKET MUST BE MARKED WITH TYPE I RETROOREFLECTIVEV MATERIAL APPRIVED IN 46 CFR 164.018 OR OTHER STANDARD SPECIFIED BY THE COMMANDANT. RETROREFLECTIVE MATERIAL WAS NOT SERVICEABLE. REPALCE RETROREFLECTIVE MATERIAL.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 February 2022
Resolved
AS APPROPRIATE FOR THE INTENDED VOYAGE, A VESSEL MUST CARRY ADEQUATE AND UP-TO-DATE CHARTS, U.S. COAST PILOT COAST GUARD LIGHT LIST, TIDE TABLES AND CURRENT TABLES. PROVIDE NAUTICAL PUBLICATIONS.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 28 February 2022
Resolved
STATIONS IN THE MARITIME SERVICE MUST BE LICENSED BY THE FCC EITHER INDIVIDUALLY OR BY FLEET. MISSING FCC STATION AUTHORIZATION CERTIFICATE.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 December 2020
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Forward and aft bulkheads in the engine room are not watertight. Seal with approved material.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 30 November 2020
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel is operated beyond the 20 nautical mile limitation, but not more than 100 nautical miles from the nearest land, and is not equipped with a MF-DSC frequency transmitter. Install proper MF-DSC radio IAW manufacturer's instructions. Until corrected, vessel operations are restricted to 20NM.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 30 November 2020
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel's VHF-DSC radio is not equipped with a GPS feed which provides full operation of the DSC alert function. Connect GPS feed to the radio via nmea data cable connector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 November 2020
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel does not have an FCC safety certificate. Ensure an FCC-licensed technician attends the vessel for a detailed inspection of the radio installations on board once every five years, obtain and maintain FCC safety certificate to be kept on board the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 November 2020
Resolved
A pre-engineered fixed gas fire extinguishing system must be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector. Vessel's Fireboy Cintex system was installed with the safety pin still in place; preventing manual activation from outside the space. Master removed red tamper seal and safety pin, and properly stowed the pin.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 November 2020
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test and make available for inspection all items in the ship's outfit, such as navigation lights and equipment. Sound signal found to be undersized for vessel length. Provide proper sound signaling device tpo include horn/bell.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 November 2020
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel is not in compliance with chemical testing program requirements. Provide all applicable employment testing results. 46CFR16.210/16.230
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 30 November 2020
Resolved
There must be a means of accurately determining the amount of fuel in each fuel tank either by sounding, through a separate sounding pipe or a fill pipe, or by an installed marine type fuel gauge. Master currently uses vessel draft references to determine fuel tank amount. Operator intends to request special consideration to allow current means of determining fuel level to meet requirements.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 March 2020
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent.
Port vent stuck open.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 March 2020
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection.
Fire extinguisher bracket in foward passenger compartment was broken.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Retro tape worn.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2020
Resolved
A vessel must have one or more ring life buoys. Replace retro.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 March 2020
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Light at operating station extinguished.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 2 March 2020
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Bilge hose too short.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 March 2020
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Hydro static release not properly mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2020
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Test all employees prior to employment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2019
Resolved
Each PFD must have at least 31 square inches of retroflective material on front side and 31 square inches on back sides. Vessel has 2 PFD's which retro tape is wasted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 February 2019
Resolved
A vessel must have at least three 2.5 gallon buckets with an attached lanyard. Vessel currently has three 5 gallon buckets. Make into 2.5 gallon buckets.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 25 February 2019
Resolved
A durable placard must be posted with the emergency broadcast instructions and information, specific to the individual vessel. Vessel does not have placard.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 February 2019
Resolved
Vessel needs a Employee Assistance Program (EAP)which must include at least the following elements: Display and distribution of informational material:display and distribution of a community service hot-line telephone number. Vessel needs to post EAP program.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 February 2017
Resolved
Ammomia inhalants missing 46 CFR 184.710
Construction/Loadline › Structures › End Bulkhead
Issued 28 February 2017
Resolved
found open hole in bulkhead fwd stbd side E/R 46 CFR 179.212
Lifesaving › Lifebuoys › Serviceable
Issued 3 December 2015
Resolved
Batteries for life buoys are expired, need to be replaced with new batteries.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 3 December 2015
Resolved
Retro tape on lifejackets are worn. Replace on 3 adult and 2 child lifejackets.
Lifesaving › Lifebuoys › Serviceable
Issued 3 December 2015
Resolved
Grab line on ring buoy is short. Replace with approved grab line and replace worn retro tape too.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 3 December 2015
Resolved
Structural fire protection in engine room needs repair work. Repair in marked spots pointed out by marine inspectors.
Communications › Radio Communications › EPIRB
Issued 3 December 2015
Resolved
Battery in EPIRB is expired. Replace with new approved battery.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 23 November 2015
Resolved
DAPI paperwork is incomplete. Provide MIS report for 2014 and random/pre-employment testing info.
Communications › Radio Communications › EPIRB
Issued 6 January 2012
Resolved
EPIRB is not registered with NOAA. Provide proof of current registration to the satisfaction of marine inspector.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 6 January 2012
Resolved
Independent generator does not shut down when pre-engineered fire fighting (Fireboy) engages. Properly incorporate generator into fireboy system to the satisfaction of attending marine inspector.
Communications › Alarms/Indicators › High Water Alarm
Issued 6 January 2012
Resolved
Visual indicators for all high level alarms (4) at the pilot house are inoperative. Repair to the satisfaction of marine inspector.
Fire Fighting › Fire Bucket › Availability
Issued 6 January 2012
Resolved
Place three (3) 2.5 gallon fire buckets with lanyard and proper markings in accordance with regulations.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 January 2012
Resolved
Complete Man Overboard and fire drills to the satisfaction of attending marine inspector.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 January 2012
Resolved
Enroll all deckhands in current drug consortium (APCA) and conduct pre-employment test prior to employment on vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 January 2012
Resolved
Replace expired ALCO test kits (2) and provide proof to marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 6 January 2012
Resolved
Replace all personal marker lights with new unexpired lights. Provide documentation to marine inspector for 15 adults and 4 child size life jackets.
Communications › Radio Communications › EPIRB
Issued 17 December 2010
Resolved
Install a new battery for the CAT I calss I EPIRB. Prior to voyages greater than 20 miles.
Lifesaving › Lifefloat › Markings
Issued 17 December 2010
Resolved
Apply name of vessel to the lifefloat with letters not less than two inches high.
Lifesaving › Lifefloat › Paddle
Issued 17 December 2010
Resolved
Provide for the lifefloat two paddles of at least 4 foot long.
Lifesaving › Lifefloat › Painter
Issued 17 December 2010
Resolved
Provide for the lifefloat a new painter of at least 100ft and meeting the requirements contained in 46 CFR 180.175 (f) (3).
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 April 2010
Resolved
Renew raw water supply hoses on the port engine (sea valve to strainer and strainer to engine), and the raw water hose from the sea valve to strainer on the stbd engine. (3 hoses in all)
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 2 April 2010
Resolved
Install proper manual actuation pull on the pre-engineered fire extinguishing system iaw 46CFR 181.400 (b)(2) and 181.420.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 2 April 2010
Resolved
Install required B-2 extinguisher outside of machinery space.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 January 2008
Resolved
Two child size life jackets need new retroreflective material.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 January 2008
Resolved
First aid kit has expired asprin, motrin, and missing large bandages'.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 27 July 2007
Resolved
Repair or replace vent covers on the port and stbd side.
Operations/Management › Drills/Instruction › Fire
Issued 27 July 2007
Resolved
Provide a log book, Conduct and log all drills and training.
Communications › Radio Communications › EPIRB
Issued 27 July 2007
Resolved
Renew hydrostatic release. The release was installed at the initial certification (10 Jan 2006) but the date was never marked.
Lifesaving › Lifebuoys › Serviceable
Issued 27 July 2007
Resolved
Renew the life ring.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 January 2005
Resolved
Automatic shutdown for the generator (internal combustion engine) located in engine compartment is to be provided for when the fixed fire extinguishing system is energized prior to operating with passengers.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 January 2005
Resolved
Valid FCC station license is to be provided for the vessel.
Lifesaving › Lifefloat › Float-free Link
Issued 10 January 2005
Resolved
Improperly sized weak link installed on lifefloat. Properly sized weak link to be installed prior to the vessel operating with passengers.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 January 2005
Resolved
Dead end wires located under operating station to be removed or properly dead ended.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 10 January 2005
Resolved
Location of A-I fire extinguisher under operating station is to be properly labeled.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 10 January 2005
Resolved
Additional B-II fire extinguisher is to be provided IWO E/R access prior to operating with passengers.
Engineering › Bilge Water Management System › Interface Detector
Issued 10 January 2005
Resolved
Bilge water high level alarm panel located at operating station is to be properly labeled.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 January 2005
Resolved
Lanyard and battery for lifefloat waterlight is to be provided prior to operating with passengers.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 January 2005
Resolved
Provide 12" rail coures IWO port and starboard operating stations.
Casualty record · 1
31 March 2010Routine · role: Involved in a Marine Casualty · activity 3725415
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.