MAURY USCG vessel records Sign in
← All vessels

ENDLESS SUMMER II

ENDLESS SUMMER II is a 2005 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2005, most recently in October 2025, along with 76 deficiencies, 2 operational controls and 1 casualty investigation in 2010.

Records from 2005 to 2025. Most recent: inspection, 6 October 2025.

Built
2005
Last inspected
6 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC8511
735325
Flag
UNITED STATES
367088490 (licence lapsed)
Maury page id
psix-735325

Inspections, by type

…with no type recorded1
Years with a record 19 calendar years (2005–2025)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)43.0 ft × 16.0 ft × 7.0 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER INT'L BOAT WORKS · FT PIERCE, FL, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portST AUGUSTINE, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 11 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC8511MMSI 367088490 · expired · compulsorily equipped · granted 25 November 2015, cancelled 28 March 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 30

6 October 2025 Deficiency Check · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8247283
21 March 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8097408
2 December 2024 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8041981
22 June 2024 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7940080
12 December 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7839582
27 February 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7662747
13 December 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7640717
28 February 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7403241
15 December 2020 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7110173
30 November 2020 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7096901
20 April 2020 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6941336
2 March 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6907993
25 February 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6632037
4 December 2018 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6591805
30 November 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6589740
1 March 2018 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6364212
28 February 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6095882
16 November 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6042056
23 November 2015 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5768534
13 March 2014 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4811680
6 January 2012 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4219672
1 August 2011 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4131957
14 December 2010 COI Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3907849
31 March 2010 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3725415
26 March 2010 Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3703222
17 March 2009 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3435025
8 January 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3126826
5 July 2007 Hull Examination · Deficiency Check · Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2984483
23 January 2006 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2572997
20 January 2005 Construction Oversight · Simplified Stability Test · Initial Certification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2277781

Deficiency record · 76

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 October 2025 Resolved
Inspector Observed 03 high level bildge alarm lights not operating to include the Engine Room, Fuel tank room and the FWD compartment. Vessel to replace lights with ones that work.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 6 October 2025 Resolved
Inspector observed completely faded oil placard card. Vessel should replace with an new legible placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2025 Resolved
Inspector observed cracking on the lifebuoy. Missing correct length of lanyard for the light. Replace lifebuoy and obtain proper line for the light attachment.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 October 2025 Resolved
Inspector observed heavily faded lifejacket donning instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2025 Resolved
Inspector observed no AMP meter on the battery charger.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 October 2025 Resolved
Inspector observed a plastic valve/plug on the port engine fuel filter. Needs to be metallic.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 12 November 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 March 2025 Resolved
Boundaries that spearate machinery spaces from accommodation spaces must be lined with noncombustible panels or insulation. Insulation above starboard engine is loose and hanging down.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 1 April 2025
Resolution: USCG MI verified deficiency has been corrected properly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 March 2025 Resolved
All escape hatches and other emergency exits must be marked on both sides "EMERGENCY EXIT, KEEP CLEAR." Escape hatch not marked.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 1 April 2025
Resolution: USCG MI verified deficiency has been corrected properly.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 March 2025 Resolved
The rules concerning lights (83.20 through 83.31) shall be complies with. Vessels stern light inoperable.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 1 April 2025
Resolution: USCG MI verified deficiency has been corrected properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025 Resolved
At each inspection test pre-engineered fire protection equipment. Green indicating light at operating station for fire protection equipment inoperable.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 1 April 2025
Resolution: USCG MI verified deficiency has been corrected properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 March 2025 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. You failed to have an annual inspection within the 3 months before or after you anniversary date of 30 November 2024.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2025
Resolution: USCG MIs completed a satisfactory Annual Inspection.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 December 2024 Resolved
46 CFR 181.450 Vessels on an oceans route must have interconnected smoke detection and be installed such that the actuation of an alarm in one area results in both audible and visual alarms in all areas. Vessel does not have any smoke detection. Smoke detection is required in at least the head and the salon.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2025
Resolved 3 January 2025
Resolution: New approved smoke detectors installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 December 2024 Resolved
46 CFR 176.600(a) Owner shall make vessel available for drydock examinations. The deck to bulkhead tab in the anchor locker has become delaminated and separated in multiple locations. Submit a repair proposal to this office detailing how the repair shall be conducted. The vessel may complete repairs in or out of the water after receiving approval of the repair plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2025
Resolved 3 January 2025
Resolution: Tab joint repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 22 June 2024 Resolved
Each vessel that operates on the high seas,must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's EPIRB has been lost and must be replaced and mounted in an accetable location to the cognizant Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 22 June 2024
Resolved 26 June 2024
Resolution: Verified new registered EPIRB was installed on vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2024 Resolved
The owner, charterer, managing operator, or master of must keep a correct list of the names of all persons that embark on and disembark from the vessel and the list shall be available to the Coast Guard upon request. Vessel was unable to provide list of crew and passengers to the Coast Guard upon request. Vessel owner must provide Coast with updated process on how passenger lists are recorded and ready upon request.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2024
Resolved 26 June 2024
Resolution: Passenger list with names will be kept by vessel captain and owner ashore for every voyage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2022 Resolved
EACH LIFE JACKET MUST BE MARKED WITH TYPE I RETROOREFLECTIVEV MATERIAL APPRIVED IN 46 CFR 164.018 OR OTHER STANDARD SPECIFIED BY THE COMMANDANT. RETROREFLECTIVE MATERIAL WAS NOT SERVICEABLE. REPALCE RETROREFLECTIVE MATERIAL.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 6 March 2022
Resolution: Photo evidence provided of retrotape, MI verified.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 February 2022 Resolved
AS APPROPRIATE FOR THE INTENDED VOYAGE, A VESSEL MUST CARRY ADEQUATE AND UP-TO-DATE CHARTS, U.S. COAST PILOT COAST GUARD LIGHT LIST, TIDE TABLES AND CURRENT TABLES. PROVIDE NAUTICAL PUBLICATIONS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 6 March 2022
Resolution: Photo evidence provided of publications, MI verified.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 28 February 2022 Resolved
STATIONS IN THE MARITIME SERVICE MUST BE LICENSED BY THE FCC EITHER INDIVIDUALLY OR BY FLEET. MISSING FCC STATION AUTHORIZATION CERTIFICATE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 23 March 2022
Resolution: FCC documents provided and verified by MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 December 2020 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Forward and aft bulkheads in the engine room are not watertight. Seal with approved material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2021
Resolved 8 January 2021
Resolution: Vessel owner provided evidence of proper sealant of the forward and aft bulkhead penetrations in the engine room, meeting the watertight integrity requirement.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 30 November 2020 Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel is operated beyond the 20 nautical mile limitation, but not more than 100 nautical miles from the nearest land, and is not equipped with a MF-DSC frequency transmitter. Install proper MF-DSC radio IAW manufacturer's instructions. Until corrected, vessel operations are restricted to 20NM.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 15 December 2020
Resolution: Observed MF-DSC radio installed IAW manufacturer's instruction and an FCC-licensed technician completed a safety certificate examination.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 30 November 2020 Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel's VHF-DSC radio is not equipped with a GPS feed which provides full operation of the DSC alert function. Connect GPS feed to the radio via nmea data cable connector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 15 December 2020
Resolution: Observed a new VHF-DSC radio installation IAW manufacturer's instruction and an FCC-licensed technician completed a safety certificate examination.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 November 2020 Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel does not have an FCC safety certificate. Ensure an FCC-licensed technician attends the vessel for a detailed inspection of the radio installations on board once every five years, obtain and maintain FCC safety certificate to be kept on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 15 December 2020
Resolution: Verified FCC-licensed technician completed a safety certificate examination, and owner has valid FCC safety certificate onboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 November 2020 Resolved
A pre-engineered fixed gas fire extinguishing system must be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector. Vessel's Fireboy Cintex system was installed with the safety pin still in place; preventing manual activation from outside the space. Master removed red tamper seal and safety pin, and properly stowed the pin.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 December 2020
Resolved 30 November 2020
Resolution: Master removed red tamper seal and safety pin, and properly stowed the pin.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 November 2020 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test and make available for inspection all items in the ship's outfit, such as navigation lights and equipment. Sound signal found to be undersized for vessel length. Provide proper sound signaling device tpo include horn/bell.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 15 December 2020
Resolution: Owner provided sound signal sufficient for vessels up to 65' in length. Owner also provided sufficiently sized 8" bell.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 November 2020 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel is not in compliance with chemical testing program requirements. Provide all applicable employment testing results. 46CFR16.210/16.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 15 December 2020
Resolution: Owner provided all applicable employment testing results, and is in compliance with the DAPI program requirements.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 30 November 2020 Resolved
There must be a means of accurately determining the amount of fuel in each fuel tank either by sounding, through a separate sounding pipe or a fill pipe, or by an installed marine type fuel gauge. Master currently uses vessel draft references to determine fuel tank amount. Operator intends to request special consideration to allow current means of determining fuel level to meet requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 7 January 2021
Resolution: O/O removed the old fuel sending unit to dip the tank with a fuel level measuring dipstick, marked with Full, 3/4, half, and 1/4 full indicating lines, then put the old sending back in to secure the opening on the fuel tank.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 March 2020 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port vent stuck open.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2020
Resolution: Master provided video of air vent fully functonal.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 March 2020 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Fire extinguisher bracket in foward passenger compartment was broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 11 March 2020
Resolution: Installed new bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2020 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Retro tape worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 11 March 2020
Resolution: New retro tape installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2020 Resolved
A vessel must have one or more ring life buoys. Replace retro.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 11 March 2020
Resolution: Retro tape replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 March 2020 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Light at operating station extinguished.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 11 March 2020
Resolution: Video provided of alarm and light fully operational at operating station.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 2 March 2020 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Bilge hose too short.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 2 March 2020
Resolution: Bildge hose mounted properly.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 March 2020 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Hydro static release not properly mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 2 March 2020
Resolution: Master properly instaled hydro static-release.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2020 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Test all employees prior to employment.
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 20 April 2020
Resolution: Employee no longer works for the company. All employees are enrolled in testing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2019 Resolved
Each PFD must have at least 31 square inches of retroflective material on front side and 31 square inches on back sides. Vessel has 2 PFD's which retro tape is wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel replaced old retro with new retro on 02 life jackets
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 February 2019 Resolved
A vessel must have at least three 2.5 gallon buckets with an attached lanyard. Vessel currently has three 5 gallon buckets. Make into 2.5 gallon buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner provided 3 2.5 gallons fire buckets
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 25 February 2019 Resolved
A durable placard must be posted with the emergency broadcast instructions and information, specific to the individual vessel. Vessel does not have placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner provided emergency broadcast instructions placard.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 February 2019 Resolved
Vessel needs a Employee Assistance Program (EAP)which must include at least the following elements: Display and distribution of informational material:display and distribution of a community service hot-line telephone number. Vessel needs to post EAP program.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner provided valid Employee Assistance Program.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 February 2017 Resolved
Ammomia inhalants missing 46 CFR 184.710
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2017
Resolved 28 February 2017
Resolution: Vessel procured new strips
Construction/Loadline › Structures › End Bulkhead
Issued 28 February 2017 Resolved
found open hole in bulkhead fwd stbd side E/R 46 CFR 179.212
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 2 March 2017
Resolution: O/o corrected deficiency by providing marine grade fire stop for e/r penetration.
Lifesaving › Lifebuoys › Serviceable
Issued 3 December 2015 Resolved
Batteries for life buoys are expired, need to be replaced with new batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2015
Resolved 8 December 2015
Resolution: New batteries were purchased and installed.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 3 December 2015 Resolved
Retro tape on lifejackets are worn. Replace on 3 adult and 2 child lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2015
Resolved 8 December 2015
Resolution: 02 child lifejackets were purchased, 03 adult life jackets were repaired.
Lifesaving › Lifebuoys › Serviceable
Issued 3 December 2015 Resolved
Grab line on ring buoy is short. Replace with approved grab line and replace worn retro tape too.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2015
Resolved 8 December 2015
Resolution: New grab line was installed.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 3 December 2015 Resolved
Structural fire protection in engine room needs repair work. Repair in marked spots pointed out by marine inspectors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2015
Resolved 8 December 2015
Resolution: Structural fire protection was repaired in marked areas.
Communications › Radio Communications › EPIRB
Issued 3 December 2015 Resolved
Battery in EPIRB is expired. Replace with new approved battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2015
Resolved 8 December 2015
Resolution: New battery was installed in EPIRB.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 23 November 2015 Resolved
DAPI paperwork is incomplete. Provide MIS report for 2014 and random/pre-employment testing info.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2015
Resolved 8 December 2015
Resolution: MIS report for 2014 and pre-employment/random test results were provided.
Communications › Radio Communications › EPIRB
Issued 6 January 2012 Resolved
EPIRB is not registered with NOAA. Provide proof of current registration to the satisfaction of marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2012
Resolution: Received email verification.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 6 January 2012 Resolved
Independent generator does not shut down when pre-engineered fire fighting (Fireboy) engages. Properly incorporate generator into fireboy system to the satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Witnessed proper operation.
Communications › Alarms/Indicators › High Water Alarm
Issued 6 January 2012 Resolved
Visual indicators for all high level alarms (4) at the pilot house are inoperative. Repair to the satisfaction of marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Witnessed proper operation.
Fire Fighting › Fire Bucket › Availability
Issued 6 January 2012 Resolved
Place three (3) 2.5 gallon fire buckets with lanyard and proper markings in accordance with regulations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Verified.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 January 2012 Resolved
Complete Man Overboard and fire drills to the satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Witnessed satisfactory drills.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 January 2012 Resolved
Enroll all deckhands in current drug consortium (APCA) and conduct pre-employment test prior to employment on vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2012
Resolution: Verified through scan copy of documents.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 January 2012 Resolved
Replace expired ALCO test kits (2) and provide proof to marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Verified.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 6 January 2012 Resolved
Replace all personal marker lights with new unexpired lights. Provide documentation to marine inspector for 15 adults and 4 child size life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Verified.
Communications › Radio Communications › EPIRB
Issued 17 December 2010 Resolved
Install a new battery for the CAT I calss I EPIRB. Prior to voyages greater than 20 miles.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2010
Resolution: Owner purchased and installed a new EPIRB on the vessel NEW Beacon ID: ADCD021E5941401.
Lifesaving › Lifefloat › Markings
Issued 17 December 2010 Resolved
Apply name of vessel to the lifefloat with letters not less than two inches high.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2010
Resolution: Owner applied the name of the vessel with 2 in high letters to the lifefloat.
Lifesaving › Lifefloat › Paddle
Issued 17 December 2010 Resolved
Provide for the lifefloat two paddles of at least 4 foot long.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2010
Resolution: The operator provided two paddles for the lifefloat.
Lifesaving › Lifefloat › Painter
Issued 17 December 2010 Resolved
Provide for the lifefloat a new painter of at least 100ft and meeting the requirements contained in 46 CFR 180.175 (f) (3).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2010
Resolution: Owner provided a new painter of 100 ft long.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 April 2010 Resolved
Renew raw water supply hoses on the port engine (sea valve to strainer and strainer to engine), and the raw water hose from the sea valve to strainer on the stbd engine. (3 hoses in all)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2010
Resolved 28 April 2010
Resolution: Hoses were replaced
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 2 April 2010 Resolved
Install proper manual actuation pull on the pre-engineered fire extinguishing system iaw 46CFR 181.400 (b)(2) and 181.420.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2010
Resolved 28 April 2010
Resolution: Manual pull installed
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 2 April 2010 Resolved
Install required B-2 extinguisher outside of machinery space.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2010
Resolution: Purchased Extinguisher; corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 January 2008 Resolved
Two child size life jackets need new retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2008
Resolution: Provided e-mail proof that retro was installed on life jackets. All SAT.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 January 2008 Resolved
First aid kit has expired asprin, motrin, and missing large bandages'.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2008
Resolution: Provided documentary proof that new first aid supplies were purchased for vessel. All sat.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 27 July 2007 Resolved
Repair or replace vent covers on the port and stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 1 August 2007
Resolution: Vent covers were repaired and are working fine.
Operations/Management › Drills/Instruction › Fire
Issued 27 July 2007 Resolved
Provide a log book, Conduct and log all drills and training.
Action required: 705 - Other - as specified
Due 27 August 2007
Resolved 1 August 2007
Resolution: Drills are logged in the new book.
Communications › Radio Communications › EPIRB
Issued 27 July 2007 Resolved
Renew hydrostatic release. The release was installed at the initial certification (10 Jan 2006) but the date was never marked.
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 1 August 2007
Resolution: New hydrostatic release installed.
Lifesaving › Lifebuoys › Serviceable
Issued 27 July 2007 Resolved
Renew the life ring.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 1 August 2007
Resolution: New life ring.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 January 2005 Resolved
Automatic shutdown for the generator (internal combustion engine) located in engine compartment is to be provided for when the fixed fire extinguishing system is energized prior to operating with passengers.
Action required: 705 - Other - as specified
Due 10 February 2006
Resolved 23 January 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 10 January 2005 Resolved
Valid FCC station license is to be provided for the vessel.
Action required: 705 - Other - as specified
Due 10 February 2006
Resolved 24 July 2007
Resolution: Vessel has valid FCC License posted onboard.
Lifesaving › Lifefloat › Float-free Link
Issued 10 January 2005 Resolved
Improperly sized weak link installed on lifefloat. Properly sized weak link to be installed prior to the vessel operating with passengers.
Action required: 705 - Other - as specified
Due 10 January 2006
Resolved 23 January 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 January 2005 Resolved
Dead end wires located under operating station to be removed or properly dead ended.
Action required: 705 - Other - as specified
Due 10 February 2006
Resolved 23 January 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 10 January 2005 Resolved
Location of A-I fire extinguisher under operating station is to be properly labeled.
Action required: 705 - Other - as specified
Due 10 February 2006
Resolved 23 January 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 10 January 2005 Resolved
Additional B-II fire extinguisher is to be provided IWO E/R access prior to operating with passengers.
Action required: 705 - Other - as specified
Due 10 February 2006
Resolved 23 January 2006
Engineering › Bilge Water Management System › Interface Detector
Issued 10 January 2005 Resolved
Bilge water high level alarm panel located at operating station is to be properly labeled.
Action required: 705 - Other - as specified
Due 10 February 2006
Resolved 23 January 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 January 2005 Resolved
Lanyard and battery for lifefloat waterlight is to be provided prior to operating with passengers.
Action required: 705 - Other - as specified
Due 10 January 2006
Resolved 23 January 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 January 2005 Resolved
Provide 12" rail coures IWO port and starboard operating stations.
Action required: 705 - Other - as specified
Due 10 February 2006
Resolved 23 January 2006

Casualty record · 1

31 March 2010Routine · role: Involved in a Marine Casualty · activity 3725415
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record