Records from 2016 to 2026. Most recent: inspection, 21 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)35.0 ft × 10.0 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFORCE MARINE INC · HILO, HI, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portKAILUA-KONA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
21 January 2026
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8299791
8 January 2025
COI Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8063187
20 February 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7867879
11 April 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7666585
25 January 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7626907
24 March 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7417653
5 November 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7346230
26 January 2021
Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7130719
29 February 2020
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6926364
29 January 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6928167
14 January 2020
Annual Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6883797
22 April 2019
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6676287
26 March 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6649629
23 January 2019
Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6614081
26 March 2018
DAPI Audit · Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6378888
15 May 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6187858
1 March 2017
Hull Examination · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6094313
23 January 2017
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6073680
27 January 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5834842
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 25 January 2023
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below. A portion of main deck FRP is cracked and water ingress into marine plywood core at the both port and starboard entry way making the deck flex.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2023
Resolved 21 March 2023
Resolution: Deck repaired and considered satisfactory.
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 March 2017
Resolved
Vessel bilge pump needs to be equipped with a working visual indicator when the pump is in operation at a central control point.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 1 April 2017
Resolution: The vessel's bilge alarm indicator was fixed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 March 2017
Resolved
Vessel needs to weld cracked area and exposed metal wear area on the port side rail of the swim step ladder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 1 April 2017
Resolution: The vessel welded the cracked area on the port side rail.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 March 2017
Resolved
Vessel needs to have a valid FCC Certificate onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 1 April 2017
Resolution: Vessel received a valid FCC Safety Certificate.