Records from 2005 to 2026. Most recent: inspection, 21 January 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
21 January 2026
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8299791
8 January 2025
COI Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8063187
20 February 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7867879
11 April 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7666585
25 January 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7626907
24 March 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7417653
5 November 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7346230
26 January 2021
Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7130719
29 February 2020
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6926364
29 January 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6928167
14 January 2020
Annual Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6883797
22 April 2019
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6676287
26 March 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6649629
23 January 2019
Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6614081
26 March 2018
DAPI Audit · Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6378888
15 May 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6187858
1 March 2017
Hull Examination · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6094313
23 January 2017
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6073680
27 January 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5834842
15 February 2011
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3900627
26 January 2010
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3670072
1 April 2009
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3443826
19 February 2009
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3420412
7 March 2008
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3159833
2 February 2007
Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2954818
21 February 2006
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2820931
21 January 2005
Deficiency Check · Initial Certification · Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2396904
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 25 January 2023
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below. A portion of main deck FRP is cracked and water ingress into marine plywood core at the both port and starboard entry way making the deck flex.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2023
Resolved 21 March 2023
Resolution: Deck repaired and considered satisfactory.
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 March 2017
Resolved
Vessel bilge pump needs to be equipped with a working visual indicator when the pump is in operation at a central control point.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 1 April 2017
Resolution: The vessel's bilge alarm indicator was fixed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 March 2017
Resolved
Vessel needs to weld cracked area and exposed metal wear area on the port side rail of the swim step ladder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 1 April 2017
Resolution: The vessel welded the cracked area on the port side rail.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 March 2017
Resolved
Vessel needs to have a valid FCC Certificate onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 1 April 2017
Resolution: Vessel received a valid FCC Safety Certificate.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 15 February 2011
Resolved
Provide valid FCC Safety Radiotelephony certificate onboard.
Due 15 March 2011
Resolved 26 April 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 February 2011
Resolved
Submit plans for USCG approval to properly secure the aft swim step to meet the railing requirements of 46 CFR 177.900 for a vessel engaged in excursion trips.
Due 15 March 2011
Resolved 6 April 2011
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 15 February 2011
Resolved
Prove operation of fixed fire extinguisher automatic engine shutdown.
Due 15 March 2011
Resolved 6 April 2011
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 26 January 2010
Resolved
During Compliance Exam found that the CG does not have complete approved vessel plans. Submit vessel plans for all applicable systems to USCG for approval i.a.w. 46 CFR 177.202
Action required: 705 - Other - as specified
Resolved 26 January 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 January 2010
Resolved
Found one B-II portable fire extinguisher not in serviceable condition. Portable fire extinguisher pressure gauge reading in the red line. Replace/recharge one B-II portable fire extinguisher.
Action required: 705 - Other - as specified
Due 9 February 2010
Resolved 28 January 2010
Resolution: Replaced portable fire extinguisher.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 January 2010
Resolved
Provide 3 to 6 foot lanyard for floating waterlight for ring buoy.
Action required: 705 - Other - as specified
Due 9 February 2010
Resolved 28 January 2010
Engineering › Bilge Water Management System › Not Operational
Issued 19 February 2009
Resolved
Prove operation of (2) high level bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2009
Engineering › Fuel Oil Service System › Flange
Issued 19 February 2009
Resolved
Provide (2) heat shields for port and stbd racor filters.
Due 6 March 2009
Resolved 23 February 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 March 2008
Resolved
Fixed gas fire fighting system did not have a means to automatically shut-down engines IAW 46 CFR 181.420(a)(3).
Action required: 705 - Other - as specified
Resolved 2 April 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 March 2008
Resolved
FIxed gas fire fighting system did not have a means to reset engines upon activation of system.
Action required: 705 - Other - as specified
Resolved 2 April 2008
Engineering › Bilge Water Management System › Not Operational
Issued 7 March 2008
Resolved
Bilge high level alarms were installed but inoperable.
Action required: 705 - Other - as specified
Resolved 14 March 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 March 2008
Resolved
Vessel did not have current copy of USCG light list on board.
Due 21 March 2008
Resolved 14 March 2008
Operations/Management › Passenger Operations › Safety Orientation
Issued 7 March 2008
Resolved
Vessel did not have copy of diver recall procedures on board for operations with reduced manning per Sector Honolulu guidance.
Due 21 March 2008
Resolved 2 April 2008
Navigation › Piloting/Steering › Marine Charts
Issued 7 March 2008
Resolved
Vessel did not have up to date navigational chart on board.
Due 21 March 2008
Resolved 14 March 2008
Lifesaving › Lifebuoys › Serviceable
Issued 7 March 2008
Resolved
Ring buoy showed deterioration. Retro reflective tape was badly worn, grab line was deteriorated and ring had several punctures in outer covering.
Due 21 March 2008
Resolved 2 July 2008
Fire Fighting › Ventilation Systems › Operating Controls
Issued 7 March 2008
Resolved
Vessel did not have means to secure ventilation to engine room where fixed gas fire fighting system was installed.
Due 21 March 2008
Resolved 14 March 2008
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 7 March 2008
Resolved
Company did not meet EAP requirements IAW 46 CFR 16.500 nor did they have proof of their 2006 and 2007 MIS submission.
Due 14 April 2008
Resolved 4 April 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 March 2008
Resolved
Did not conduct drills due to problems with fixed gas fire fighting system and inoperable high level bilge alarms.
Action required: 705 - Other - as specified
Resolved 14 March 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 February 2007
Resolved
Properly cover batteries to protect from exposure to water
Due 2 March 2007
Resolved 20 February 2007
Engineering › Fuel Oil Service System › Valve
Issued 2 February 2007
Resolved
Label fuel shut offs
Due 2 March 2007
Resolved 20 February 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 February 2007
Resolved
Provide original copy of COD
Due 2 March 2007
Resolved 20 February 2007
Construction/Loadline › Hull › Hull Plating
Issued 2 February 2007
Resolved
Make proper repairs to port quarter as discussed
Due 2 March 2007
Resolved 6 March 2007
Communications › Radio Communications › EPIRB
Issued 2 February 2007
Resolved
Verify hydrostatic release expiration date to EPIRB
Due 2 March 2007
Resolved 20 February 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 February 2007
Resolved
Prove proper operation of port running light and anchor light
Due 2 March 2007
Resolved 20 February 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 2 February 2007
Resolved
Make drug and alcohol program available for inspection
Due 2 March 2007
Resolved 6 March 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 21 February 2006
Resolved
Have all firefighting serviced
Due 21 March 2006
Resolved 23 March 2006
Communications › Radio Communications › EPIRB
Issued 21 February 2006
Resolved
Install EPIRB in a float free arrangement
Due 21 March 2006
Resolved 23 March 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 21 February 2006
Resolved
Obtain Coast Pilot and tides & currents
Due 21 March 2006
Resolved 23 March 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 February 2006
Resolved
Add temporary railing to both port and stbd embarkation
Due 21 March 2006
Resolved 23 March 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 February 2006
Resolved
Label vessel name on lifering
Due 21 March 2006
Resolved 23 March 2006
Engineering › Bilge Water Management System › Hose
Issued 21 February 2006
Resolved
Obtain longer hose for portable hand pump
Due 21 March 2006
Resolved 23 March 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 February 2006
Resolved
Replace netting for railings
Due 21 March 2006
Resolved 23 March 2006
Documentation › Certificates/Documents › FCC SSL
Issued 21 January 2005
Resolved
Obtain valid FCC certificates (Station License and Safety Radiotelephony). Vessel is restricted to operating within 1000 ft from shore until this requirement is met to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 6 June 2005
Documentation › Markings/Placards › Warning Signs
Issued 21 January 2005
Resolved
Post radio broadcast placard.
Due 26 February 2005
Resolved 23 February 2005