MAURY USCG vessel records Sign in
← All vessels

PACIFIC SOPHIA

PACIFIC SOPHIA is a 2004 freight ship. The Coast Guard has recorded 17 inspections since 2005, most recently in April 2026, along with 7 deficiencies and 4 operational controls, 1 with no removal date recorded.

Records from 2005 to 2026. Most recent: inspection, 6 April 2026.

Built
2004
Last inspected
6 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9274927 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
736078
Flag
PANAMA
—
Maury page id
psix-736078

Inspections, by type

…with no type recorded6
Years with a record 10 calendar years (2005–2026)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it30064 - Convention (Subpart B), Gross Ton
17927 - Convention (Subpart B), Net Ton
52501 - Dead Weight, Ton
60772 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

6 April 2026 Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8343383
22 December 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7612121
30 January 2020 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6897682
20 August 2018 MARPOL Annex I Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6517818
13 August 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6510155
26 April 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5857346
25 April 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5862155
7 June 2012 PII Safety Exam · ISPS I Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4331382
6 June 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4336412
2 June 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4331792
1 June 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4331431
13 July 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4074122
27 January 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2862596
19 October 2006 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2803980
9 April 2005 PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2328900
7 February 2005 PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2287140
3 February 2005 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2286190

Deficiency record · 7

Engineering › Diesel Engine (propulsion-direct drive) › Charge Air Cooling
Issued 7 June 2012 Resolved
1410-Propulsion Main Engine-Main engine after cooler has a wooden plug installed, preventing the leakage of jacket water. SOLAS 74 (a) I/11
Action required: 705 - Other - as specified
Due 21 June 2012
Resolved 18 December 2012
Resolution: The wooden plug was removed and replaced with a bolt and is considered satisfactory.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 7 June 2012 Resolved
1499-Other (Prop & Aux. Machinery)-Each bunker line transfer pipe must be annually tested and not leak under static liquid pressure at least 1.5 times the max allowable working press. Vessel conducted annual test however, air was used as a medium. 33 CFR 156.170
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 18 December 2012
Resolution: The bunker lines were tested using water to a pressure of 1.5 times the M.A.W.P. and is considered satisfactory.
Fire Fighting › Ventilation Systems › Ducts
Issued 13 July 2011 Resolved
Means of control shall be provided for opening and closing of the manual fire dampers for the prevention of fire. Ventilating srystem over the air compressor's, beside the L/O tank is not functioning properly. Fire Dampers shall be tested IAW SOLAS and the ship's management system. SOLAS 74 (09) II-2/5.2.2.1 - 70(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 June 2012
Resolution: PSCO completed visual inspection of the proper operation on vent damper
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 13 July 2011 Resolved
Vessel did not submit a Notice of Intent. Informed vessel master of the EPA Vessel General Permit and provided the VGP Fact Sheet with the requirements to submit a Notice of Intent to the U.S. Environmental Protection Agency. 40 CFR 122.2 [name withheld], [phone withheld], [email withheld], SECTOR CHARLESTON, SC,
Action required: 705 - Other - as specified
Due 13 July 2011
Resolved 7 June 2012
Resolution: PSCO completed visual inspection of VGP and Notice of Intent, all sat.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 27 January 2007 Resolved
The vessel has not prepared or submitted a Non-Tank Vessel Response Plan to the United States Coast Guard.
Due 1 July 2008
Resolved 13 July 2011
Resolution: USCG Sector Charleston inspection team verified that the vessel had a valid Non-Tank VRP
Documentation › Certificates/Documents › IOPP Certificate
Issued 7 February 2005 Resolved
Include the incinerator waste oil service and settling tanks in block three of the IOPP. MARPOL 73/78 I
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 April 2005
Resolution: Inspected to satisfaction of Marine Inspector
Documentation › Logs/Records › Oil Record Book
Issued 7 February 2005 Resolved
Commence making entries into the oil record book as per the instructions found in appendix III of annex I of MARPOL 73/78 where the quantity of contents retained is missing under the C-12-2 & 3 entries.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 April 2005
Resolution: Inspected to satisfaction of Marine Inspector

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.