MAURY USCG vessel records Sign in
← All vessels

HOLY CHUTE

HOLY CHUTE is a 2005 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2005, most recently in August 2024, along with 52 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2006 and 2019.

Records from 2005 to 2024. Most recent: inspection, 12 August 2024.

Built
2005
Last inspected
12 August 2024
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF6820
736777
Flag
UNITED STATES
367478160 (licence lapsed)
Maury page id
psix-736777

Inspections, by type

…with no type recorded2
Years with a record 17 calendar years (2005–2024)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CLERMONT, NJ, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portFT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 8 February 2005
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF6820MMSI 367478160 · expired · compulsorily equipped · granted 4 February 2011, cancelled 10 April 2021
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 29

12 August 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7979427
9 March 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7646824
3 February 2023 Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7631473
24 January 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7384460
1 December 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7359486
4 December 2020 Deficiency Check · Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7054285
6 August 2020 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7043168
19 November 2019 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6799597
8 February 2019 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6623842
14 January 2019 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6570979
19 November 2018 Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6570885
14 December 2017 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6325907
9 February 2017 DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6093705
11 January 2017 Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6069140
11 February 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5811440
6 February 2012 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4244157
3 February 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3937954
25 January 2011 Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3932678
26 January 2010 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3670186
8 July 2009 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3527955
30 January 2009 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3402216
15 January 2009 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3394649
4 February 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3141505
31 May 2007 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2947850
31 May 2006 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2665887
10 February 2006 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2583242
31 January 2006 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2577668
28 April 2005 Initial Certification
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2343827
5 January 2005 Plan Review "T" Boat · Construction Oversight · Simplified Stability Test
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2344642

Deficiency record · 52

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 August 2024 No resolution recorded
No vessel which is required by § 67.7 to be documented may engage in unlimited coastwise trade or the fisheries without being documented in accordance with the requirements of this part. Vessel's COD expired 31 July 2024.
Condition: Invalid
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2023 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is prohibited from operations until a drydock examination and an internal structural exam has been completed by a US Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2023
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 1 December 2021 Resolved
The current Certificate of Documentation was not on board. Provide and maintain the original Certificate of Documentation on board the vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2021
Resolved 9 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 December 2021 Resolved
Vessel had 04 adult and 01 child-size life jackets that were not in serviceable condition. Provide a total of 14 adult and 2 child-size life jackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 December 2021
Resolved 1 December 2021
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 January 2019 Resolved
Fractures found on 3 of the 4 blade roots at hub connection on prop. Repair/replace propeller, if repairing provide servicing facility report attesting to structural integrity.
Action required: 705 - Other - as specified
Resolved 23 January 2019
Resolution: Prop switched with spare prop that had been serviced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 January 2019 Resolved
Cutlass bearing d-laminating from housing and a section is missing. Replace cutlass bearing.
Action required: 705 - Other - as specified
Resolved 18 January 2019
Resolution: replaced cutlass bearing
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 January 2019 Resolved
Steering gear is unbonded to vessel. Bond steering.
Action required: 705 - Other - as specified
Resolved 18 January 2019
Resolution: rebonded steering gear
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 January 2019 Resolved
Hydraulic steering ram leaking hydraulic fluid and connection to rudder post is very loose. Repair/replace hydraulic ram and demonstrate proper operation of steering ram connection point to rudder post.
Action required: 705 - Other - as specified
Resolved 18 January 2019
Resolution: replaced hydraulic ram and demonstrated proper operation of steering ram connection point to rudder post
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 January 2019 Resolved
Remove dead end wires (port battery negative post, Engine room Transom).
Action required: 705 - Other - as specified
Resolved 18 January 2019
Resolution: removed wire off battery and capped wire in engine room. wires were from old blower.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 January 2019 Resolved
Renew gasket on hatch for battery compartment, gasket missing sections.
Action required: 705 - Other - as specified
Resolved 18 January 2019
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 14 January 2019 Resolved
Deck core around cover to Hydraulic tank space found rotted due to water damaged, core is made of balsa wood. Submit plans to OCMI/Marine Inspector prior to repair.
Action required: 705 - Other - as specified
Resolved 17 January 2019
Resolution: Cut out rotted section and put a new cover in and sealed it properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 January 2019 Resolved
Properly secure stanchions to deck, screws were found loose (near roller head and port rail).
Action required: 705 - Other - as specified
Resolved 16 January 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 14 January 2019 Resolved
Engine room bilge overboard shutoff valve missing handle, demonstrate proper operation of valve. Provide hose clamp for deck drain hose in engine room.
Action required: 705 - Other - as specified
Resolved 23 January 2019
Resolution: Valve replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 January 2019 Resolved
Bottom of vessel on Starboard hull has 3 blisters that need to be ground down to good glass. If FRP repair is needed submit plans for repair layup schedule.
Action required: 705 - Other - as specified
Resolved 18 January 2019
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 19 November 2018 Resolved
Repair/replace LED/audible Indicator Lamp on pre-engineered fixed fire extinguishing system. No audible alarm sounded when tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 December 2018
Resolution: LED indicators replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 November 2018 Resolved
Repair/replace hatch securing device for "Belly Compartment".
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 December 2018
Resolution: Hatch securing device replaced.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 November 2018 Resolved
Provide updated U.S. Coast Pilot for the area of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 December 2018
Resolution: All publications on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 November 2018 Resolved
Post COI and Stability Letter, or post sign that indicates vessel documents are available upon request.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 December 2018
Resolution: Sign posted.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 November 2018 Resolved
Submit plans to local OCMI to reconfigure closure devices for engine room ventilation. Current configuration for closing ventilation does not provide adequate closure to contain agent that will be released by fixed gas extinguishing system (Fireboy). A plastic canvas material using button snaps is the current method for closing vents.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 December 2018
Resolution: New covers constructed, CID approved design.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 December 2017 Resolved
Provide 01 serviceable child PFD. Vessel restricted to carrying 10 passengers.
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 19 December 2017
Resolution: PFD provided.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 December 2017 Resolved
Demonstrate operation of visual indicator for automatic bilge pump (forward compartment).
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 19 December 2017
Resolution: Visual indicator functioned properly.
Engineering › Fuel Oil Service System › Valve
Issued 14 December 2017 Resolved
Mark/Label remote fuel shutoff's
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 19 December 2017
Resolution: Marked properly.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 December 2017 Resolved
Provide simple instructions for operation of fixed fire extinguishing system at pull box.
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 19 December 2017
Resolution: Posted.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 14 December 2017 Resolved
Provide 5 year service receipt or hydro fixed fire extinguishing system cylinder. May replace cylinder as well.
Action required: 705 - Other - as specified
Due 14 January 2018
Resolved 16 March 2018
Resolution: New cyclinder installed onboard.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 February 2017 Resolved
Install visual indicators for aft automatic bilge pump
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 21 February 2017
Resolution: Replaced LEDs on indicator.
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 February 2017 Resolved
Make penetrations through engine room bulkhead vapor tight
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 21 February 2017
Resolution: Filled penetration with fire retardant foam
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 9 February 2017 Resolved
Renew port fuel tank sending unit
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 14 March 2017
Resolution: Installed new sending unit
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 9 February 2017 Resolved
Provide first aid kit with all required contents
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 21 February 2017
Resolution: Purchased approved first aid kit
Communications › Radio Communications › VHF Radiotelephone
Issued 9 February 2017 Resolved
Provide VHF with GPS input
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 14 March 2017
Resolution: Installed new VHF
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 11 January 2017 Resolved
Renew starboard fuel tank fill hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2017
Resolution: Installed new hose
Engineering › Fuel Oil Service System › Tank
Issued 11 January 2017 Resolved
Electrically bond fuel tanks to common ground
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 13 January 2017
Resolution: Bonded fuel tanks
Stability › Watertight Integrity › Weathertight Enclosure
Issued 6 February 2012 Resolved
Forward deck hatch must be watertight.
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 15 February 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 February 2012 Resolved
Repair 02 fractures on portside of the inflation arch.
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 15 February 2012
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 February 2012 Resolved
Install 60 feet of dark line attached to life ring buoy.
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 6 February 2012
Resolution: 60 feet of line installed during the inspection.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 6 February 2012 Resolved
Replace broken glass gauge at operating station.
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 15 February 2012
Stability › Watertight Integrity › General
Issued 6 February 2012 Resolved
Recaulk forward engine hatch insert.
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 15 February 2012
Engineering › Steering Gear System › Follow-up Assembly
Issued 6 February 2012 Resolved
Acquire means for emergency steering.
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 6 February 2012
Resolution: Emergency steering system located during inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 February 2012 Resolved
Replace battery in float light.
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 6 February 2012
Resolution: Battery replaced during the inspection.
Communications › Radio Communications › EPIRB
Issued 3 February 2011 Resolved
Mark hydrostatic release for EPIRB with proper expiration date.
Due 3 February 2011
Resolved 3 February 2011
Resolution: Expiration date marked on hydrostatic release.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 3 February 2011 Resolved
Acquire 01 portable light to be kept onboard.
Due 3 February 2011
Resolved 3 February 2011
Resolution: Light acquired to be kept onboard vessel.
Lifesaving › Lifebuoys › Stowage
Issued 3 February 2011 Resolved
Install clip on lifering buoy strobe light line.
Condition: Improper Installation
Due 3 February 2011
Resolved 3 February 2011
Resolution: Clip installed on lifering buoy.
Documentation › Certificates/Documents › FCC SSL
Issued 3 February 2011 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 10 February 2011
Resolved 3 February 2011
Documentation › Certificates/Documents › FCC SSL
Issued 3 February 2011 Resolved
Provide valid radiotelephony certificate.
Due 10 February 2011
Resolved 3 February 2011
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 January 2011 Resolved
Install gasket around forward deck hatch to make watertight.
Due 25 January 2011
Resolved 26 January 2011
Stability › Watertight Integrity › General
Issued 25 January 2011 Resolved
Repair forepeak hatch.
Due 25 January 2011
Resolved 28 January 2011
Lifesaving › Hand Flares › Quantity
Issued 26 January 2010 Resolved
KW01 Acquire 04 red hand held flares
Due 26 January 2010
Resolved 26 January 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 January 2010 Resolved
KW02 Acquire USCG approved first aid kit
Due 26 January 2010
Resolved 26 January 2010
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 January 2010 Resolved
KW03 Affix new retro reflective tape to life ring buoy where it has been damaged.
Due 26 January 2010
Resolved 26 January 2010
Engineering › Bilge Water Management System › Interface Detector
Issued 26 January 2010 Resolved
KW04 Repair bilge alarm at operating station to be audible and visual, prove proper operation.
Due 26 January 2010
Resolved 26 January 2010
Engineering › Steering Gear System › Rudder
Issued 26 January 2010 Resolved
. KW05 Acquire secondary means of steering.
Due 26 February 2010
Resolved 1 February 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 June 2006 Resolved
Provide proof of servicing for all fire fighting extinguishers IAW 46 CFR 176.810(a)(1).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2006
Construction/Loadline › Hull › Hull Plating
Issued 10 February 2006 Resolved
Submit repair proposal for damage to the hull.
Action required: 705 - Other - as specified
Due 10 March 2006
Resolved 27 March 2006
Resolution: Sec [name withheld] advised vessel inspected sat.

Casualty record · 2

31 January 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 3 injured · activity 2577668
8 February 2019Routine · role: Involved in a Marine Casualty · activity 6623842
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record