AFRICAN IBIS is a 2004 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in November 2021, along with 1 deficiency and 3 operational controls.
Records from 2016 to 2021. Most recent: inspection, 3 November 2021.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it20211 - Convention (Subpart B), Gross Ton 10948 - Convention (Subpart B), Net Ton 32347 - Dead Weight, Metric Ton 39677 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
3 November 2021Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7343072
29 July 2021Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7265757
31 January 2020PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6893881
30 January 2020Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6894631
5 July 2016Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5929826
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 6 July 2016Resolved
2550: The fire integrity of divisions shall be maintained at openings and penetrations. Multiple pipe duct spaces throughout decks A-C were found to have holes drilled through the fire boundaries for the running of wires, compromising the integrity of the boundary. 74 SOLAS (04 CONS.) II-2/9.1.3; 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2016
Resolved 18 July 2016
Resolution: Received, reviewed, and accepted photographic evidence attesting to repair of holes with fire-rated putty.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National