Records from 2016 to 2025. Most recent: inspection, 28 July 2025.
Documentation record
Registered dimensions (L × B × D)26.8 ft × 10.0 ft × 4.9 ft
Registered tonnagegross 8 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFORTIER BOATS · SOMERSET, MA, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBEVERLY, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 July 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 11
28 July 2025
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8196512
30 April 2025
Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8108807
16 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7911362
5 May 2023
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7677317
24 May 2022
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7429369
26 May 2021
Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7207511
1 May 2020
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6944426
17 May 2019
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6672771
1 May 2018
Annual Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6404510
2 May 2017
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6137481
6 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5872267
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 15 May 2025
Resolved
The master of a vessel, except a vessel listed in § 185.502(a) of this part, shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Operator not logging passenger counts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 28 July 2025
Resolution: Vessel logging passenger counts correctly iaw Sector Boston SOP.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 30 April 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions were not posted at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 23 May 2025
Resolution: Operator posted emergency instructions on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached; Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. MI observed that lifeline attached to ring buoy was severely sun faded.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2024
Resolution: Operator provided objective evidence that the lifeline had been replaced accordingly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2024
Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. MI observed an area of chafe on the inside edge of the lifebuoy that has exposed the foam to the elements.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2024
Resolution: Operator provided opjective evidence that the ring buoy had been replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 May 2024
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. MI observed there was no valid COD on board at the time of inspection. Operator provided proof that they had submitted the application and are awaiting the document.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2024
Resolution: Operator provided a copy of the COD via email as proof they had registered the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2021
Resolved
The number and identification of the items stowed inside, and their size, must be marked clearly legible letters and numbers on each container for the life jackets. Letter and number must be at least 2 inches high. symbols must be at least 4 inches square. There were not numbers indicating the amount of child and adult life jacket where they were stowed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Received email from operator with pictures of new labeling for life jacket stowage.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 May 2021
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to satisfaction of the officer in charge, Marine Inspection. The portable extinguisher was not mounted on a manufacture approved bracket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Recieved email with pictures from operator with newly installed extinguisher bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2019
Resolved
Each life ring buoy must be approved in accordance with 46 CFR 160.050. Grab line on life ring buoy is wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2019
Resolution: Operator purchased a new life ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2019
Resolved
Each floating water light must have a lanyard of at least 3 feet in length secured to the body of the ring life buoy. Lanyard on floating water is wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2019
Resolution: Operator purchased a new line for the life ring buoy light.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 May 2018
Resolved
Water light battery needs to be replaced prior to night operations, CORRECTED ON THE SPOT 46CFR180.175.
Action required: 10 - Deficiency Rectified
Due 1 May 2018
Resolved 1 May 2018
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 May 2018
Resolved
Aft deck hatch was seized and would not open, CORRECTED ON THE SPOT 46CFR179.360.
Action required: 10 - Deficiency Rectified
Due 1 May 2018
Resolved 1 May 2018
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 May 2016
Resolved
replace Hi water alarm indicator, light does not work, by 19MAY16 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 18 May 2016
Resolution: HI water alarm light was installed on console.
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2016
Resolved
Replace retro on ring buoy by 19MAY16 46CFR185.604.
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 18 May 2016
Resolution: Retro on life rings was replaced.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 6 May 2016
Resolved
Provide name of VSL on port and STB bow, 4 “ lettering by 19MAY16 46CFR67.123.
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 18 May 2016
Resolution: Name in 4" letters placed on port and starboard bow.