Records from 2016 to 2026. Most recent: inspection, 7 May 2026.
Inspection history · 15
7 May 2026
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8368570
11 March 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8324333
9 October 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8250158
2 December 2024
Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8042008
1 March 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7872862
29 November 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7831307
1 February 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7630569
14 September 2022
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7579104
16 February 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7397476
20 January 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7128279
8 January 2020
COI Inspection · Hull Examination · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6885284
6 November 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6576295
3 April 2018
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6388116
17 January 2017
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6072092
25 February 2016
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5822434
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 March 2026
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 07 adult life jackets were found to be past their service life. Passenger count reduced by 07 passengers, Provide new adult life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2026
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 March 2026
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Provide maintenance log for portable extinguishers as required by this CFR.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2026
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 2 January 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. During the hull inspection it was noted that the vessel had a cracked weld on the fwd port side rail (gunwale) and at the top of the transom on the port side of center. Repair to the satisfaction of the attending MI.
46 CFR 177.100
Code 16 c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 January 2025
Resolved 7 January 2025
Resolution: New welds in place.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 2 January 2025
Resolved
A vessel must carry either a first aid kit approved under 199.175 (b)(10) or a kit with equivalent contents. The vessels first aid kit had expired eyewash and did not have ibuprofen. Replace to the satisfaction of the attending MI.
46 CFR 184.710
Code 16 c
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 January 2025
Resolved 7 January 2025
Resolution: Contents provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 March 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 12 March 2024
Resolution: New COI issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 December 2023
Resolved
A vessel must carry one floating water light unless it is limited to day time operations. Vessel owner must produce a working life buoy light to the satisfaction of the attending MI. Vessel is restricted to day light operations until cleared.
46 CFR 180.70 (d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2023
Resolution: New light installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 September 2022
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. Mark vsl name on all child and adult lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 September 2022
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that:
the pump is listed by an independent laboratory as meeting the requirements in UL 1113. Install approved electric bilge pumps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 September 2022
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: The pump is permanently mounted. Secure starboard bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 September 2022
Resolved
A flexible tube or hose may be used instead of fixed pipe for the discharge line of a submersible electric bilge pump. Replace bilge hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2022
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter. Prove operation of water light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Provide first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 September 2022
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Install machinery guards around rotating machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2022
Resolved
An adult lifejacket must be provided for each person carried on board a vessel. Replace two deteriorated adult life jackets.
Action required: 10 - Deficiency Rectified
Due 16 February 2022
Resolved 16 February 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 February 2022
Resolved
At least one ring life buoy must be fitted with a lifeline. Provide lifeline for ring life buoy.
Action required: 10 - Deficiency Rectified
Due 16 February 2022
Resolved 16 February 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 February 2022
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Mark vessel name on ring life buoy.
Action required: 10 - Deficiency Rectified
Due 16 February 2022
Resolved 16 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 November 2018
Resolved
Properly repair port side fan cage.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 16 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2018
Resolved
Renew covers for breaker in electrical panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 16 February 2022
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 April 2018
Resolved
Vessel restricted to daylight operations only until water light is provided.
Condition: Improper/Lack of Maintenance
Due 3 May 2018
Resolved 9 April 2018
Lifesaving › Lifebuoys › Stowage
Issued 17 January 2017
Resolved
Remount life ring for easier access and deployment.
Condition: Design Flaw
Due 24 January 2017
Resolved 26 January 2017
Engineering › Bilge Water Management System › Pump
Issued 17 January 2017
Resolved
Provide 5GPM portable bilge pump.
Condition: Improper/Lack of Maintenance
Due 24 January 2017
Resolved 26 January 2017