MAURY USCG vessel records
← All vessels

ARROW LADY

ARROW LADY is a 2004 freight ship. The Coast Guard has recorded 7 inspections since 2018, most recently in July 2021, along with 3 deficiencies and 1 operational control.

Records from 2018 to 2021. Most recent: inspection, 12 July 2021.

Built
2004
Last inspected
12 July 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 July 2021
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2018–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9304215
9HA5284
737568
Flag
MALTA
Maury page id
psix-737568

Documentation record

Tonnage as PSIX records it40040 - Convention (Subpart B), Gross Ton
87409 - Displacement, Metric Ton
76752 - Dead Weight, Metric Ton
25318 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

12 July 2021 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7242393
12 March 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6925441
11 October 2019 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6833001
10 October 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6822602
9 October 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6830901
28 September 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6823149
21 February 2018 PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6357168

Deficiency record · 3

10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 11 October 2019 Resolved
Each vessel of 10000 gross tons or more must have a second marine radar system that operates independently of the other. Vessels X-Band radar is inpoperable.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 March 2020
Resolution: Received tech report and CAR.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 10 October 2019 Resolved
14799-The master owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the water of the United States must follow these practices, remove fouling organisms from the vessels hull in accordance with local, state, and federal regulations. PSCO observed significant biofouling on vessels hull. -33CFR151.2050(f)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 March 2020
Resolution: Recviewed dry dock report, class statement and car.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 February 2018 Resolved
ANY SHIP OF 10,000 GROSS TONNAGE AND ABOVE SHALL BE FITTED WITH OIL FILTERING EQUIPMENT COMPLYING WITH PARAGRAPH 7 OF THIS REGULATION. PSCO FOUND OWS DOES NOT MEET THE STANDARD OF MEPC 60(33) DUE TO INOPERABLE RETURN SOLENOID VALVE. (MARPOL ANNEX I/14.2 40AC)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 March 2018
Resolution: 21MAR2018 Received a class report satisfying the requirement. Cleared 01 deficiencies. 00 deficiencies remain outstanding.

Ownership record