MARQUETTE

MARQUETTE is a 1957 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1985, most recently in October 2025, along with 106 deficiencies, 2 operational controls and 5 casualty investigations between 2008 and 2013.

Records from 1985 to 2025. Most recent: inspection, 14 October 2025.

Built
1957
Last inspected
14 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC2385
Flag
UNITED STATES
366992270
Maury page id
psix-73759

Inspections, by type

…with no type recorded11
Years with a record 35 calendar years (1985–2025)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.6 ft × 15.0 ft × 5.5 ft
Registered tonnagegross 39 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBURGER BOAT COMPANY · MANITOWOC WI · built 1957
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Net Ton
39 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC2385MMSI 366992270 · active · compulsorily equipped · granted 15 November 2024, expires 20 November 2034
WCO7115MMSI not assigned · expired · compulsorily equipped · granted 9 November 1994, cancelled 15 January 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 81

14 October 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8251436
5 August 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7974599
22 July 2024 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7963989
18 January 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7851228
28 November 2023 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7830401
8 November 2023 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7821572
7 October 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7575683
8 September 2022 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7546931
29 July 2022 Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7523024
15 November 2021 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7351310
16 September 2021 Administrative Inspection · Internal Structural Exam · Drydock Exam · Construction Oversight · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7321753
19 May 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5881534
27 October 2015 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5752000
11 June 2014 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4886291
21 May 2014 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4864047
12 July 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4377846
18 June 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4349370
30 May 2012 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4333580
21 August 2011 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4123882
15 July 2011 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4082349
10 April 2009 Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3447467
14 October 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3344230
19 July 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3274662
18 July 2008 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3474815
19 June 2008 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3238837
30 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3222108
2 April 2008 Plan Review "T" Boat
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3176255
14 December 2007 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3115794
20 November 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3101587
19 September 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3054322
28 June 2006 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2694696
8 June 2006 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2673789
7 June 2006 Simplified Stability Test
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2672862
4 November 2005 Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2529793
26 April 2004 Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2050832
21 November 2003 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1950765
15 May 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1792891
2 May 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1607614
11 August 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 104243
5 August 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1071073
19 July 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 98608
1 June 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 113999
11 May 2001 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1423570
9 June 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1420333
25 October 1999 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1395291
4 September 1999 Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1117476
6 May 1999 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1126894
6 November 1998 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1469560
23 June 1998 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 795488
4 May 1998 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1418340
7 July 1997 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1398715
25 November 1996 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1428715
15 August 1996 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1089099
8 May 1996 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1355799
11 May 1995 Deficiency Check · COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1355324
18 May 1994 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1382769
6 July 1993 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1455075
18 May 1992 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 955976
11 March 1992 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1258519
17 October 1991 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 938755
4 October 1991 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1246694
27 September 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900317
15 August 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 916922
4 June 1990 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214886
22 May 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 903236
2 May 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223738
3 April 1990 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 898785
20 February 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1234161
12 October 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1034035
2 May 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1043632
10 March 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1205273
22 February 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1352038
11 October 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 886549
4 August 1988 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1313858
4 August 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1343806
14 July 1988 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1210513
26 October 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1021740
21 October 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1329574
4 September 1987 Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1003521
13 August 1986 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1001018
29 August 1985 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 991094

Deficiency record · 106

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: (c) Minimize accidental personnel contact with energized parts. 120v engine room electrical panel was missing a blank plate.
Action required: 10 - Deficiency Rectified
Resolved 14 October 2025
Resolution: Corrected prior to completion of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 14 October 2025 Resolved
The master of the vessel shall ensure that: (c) The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Monthly tests are not being logged.
Action required: 10 - Deficiency Rectified
Resolved 14 October 2025
Resolution: Master tested EPIRB and logged test.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 July 2024 Resolved
ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF OCMI. A POWER PANEL IN THE ENGINE ROOM HAS AN OPEN EXOSED CIRCUIT BREAKER SLOT. INSTALL A SLOT COVER FOR EXPOSED OPENING.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 5 August 2024
Resolution: Exposed circuit breaker slot has been covered.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 July 2024 Resolved
ALL ELECTICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF OCMI. AN OVERHEAD J-BOX IN THE SWTEERING SPACE HAS AN EXPOSED KNOCK-OUT HOLE. INSTALL KNOCK-OUT PLUG IN EXPOSED HOLE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 5 August 2024
Resolution: Exposed hole has installed knock-out plug.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 July 2024 Resolved
THE INSTALLATION OF PORTABLE EXTINGUISHERS MUST BE TO THE SATISFACTION OF THE [name withheld] LOCATED IN THE ENGINE ROOM AND OUTSIDE THE SPACE WTD NEED TO BE INSTALLED WITH APPROVED BRACKET #435793.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2024
Resolved 5 August 2024
Resolution: Approved brackets have been installed for portable extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2024 Resolved
AN ADULT LIFE JACKET MUST BE PROVIDED FOR EACH PERSON CARRIED ON BOARD AS PER COI. VESSEL HAS 56 SERVICEALBE LIFE JACKETS AND REQUIRES 57. PROVIDE REQUIRED LIFE JACKET AND VESSEL IS RESTRICTED TO 56 ADULT PASSENGERS UNTIL REPLACED.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 22 July 2024
Resolution: New Type I life jacket was provided on board.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 28 November 2023 Resolved
All portlights which are permitted in a vessel’s sides on vessels operating on exposed or partially-protected waters, whether of the opening or fixed type, shall be fitted with dead covers. (46 CFR 178.40-1(c)-1969) Provide dead covers for six (6) portlights in the forward space, readily accessible for use in case of emergency. The vessel is restricted to the waters of the Chicago River, west of the Chicago lock during the winter season (October 1 – April 15) and to the waters of Lake Michigan west of the outer Chicago breakwalls and north of a track line established between the dome of the Adler Planetarium and the outer breakwall south end light 19980 during the summer season (April 16 – September 30).
Action required: 705 - Other - as specified
Resolved 18 January 2024
Resolution: Deadlight covers for all portlights have been provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 November 2023 Resolved
All portlights which are permitted in a vessel's sides on vessels operating on exposed or partially-protected waters, whether of the opening or fixed type, shall be fitted with dead covers. (46 CFR 178.40-1(c)- 1969) Provide dead covers for six (6) portlights in the forward space, readily accessible for use in case of emergency.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 28 November 2023
Resolution: CG-835V re-issued w/restrictions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2022 Resolved
Vessels operator insalled a Hot Water Heater and Hand drier without Coast Guard approval or submission of plans prior to installation. Tag out and disconnect units and prior to placing in service submit plans for review and approval to the Marine Safety Center(MSC)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2022
Resolved 7 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2022 Resolved
Vessels air receiver could not be proven to meet ASME U or UM. Provide onboard an air receiver that meets these standards or one that bears a Coast Guard Propeller stamp.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2022
Resolved 7 October 2022
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 8 September 2022 Resolved
Vessels PA was removed during renovations. Prior to carrying passengers install pa system and prove proper operation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2022
Resolved 14 September 2022
Resolution: Video evidence of PA System installed and operational was provided to local OCMI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 September 2022 Resolved
Watertight door in the forward bulkhead of the engineroom is not properly marked. Properly label with 1 inch letters watertight door keep closed on both sides of door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2022
Resolved 15 September 2022
Resolution: WTD for engine room has been properly labeled on both sides.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 September 2022 Resolved
During testing of Fixed Bilge system the suction check valve in the engineroom was found fracture. Renew and prove proper operation. Also, the forepeak compartment bilge suction is missing the pick up strainer. provide and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2022
Resolved 15 September 2022
Resolution: Repairs were made to forward void and engine room installed bilge suctions, proper operation was proven.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 8 September 2022 Resolved
Emergency proceedures where not posted onboard. Post in areas of vessel for crews to reference in an emergency.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2022
Resolved 15 September 2022
Resolution: Emergency procedures have been posted on port/stbd sides of operating stations for crew to see.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2022 Resolved
Polarity was found reversed causing outlets to not have proper overcurrent protection under the console and in the forward compartment. Properly wire and prove proper operation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2022
Resolved 15 September 2022
Resolution: Electrical outlets had reverse polarity readings found, contracted electricains rectified, verified with ET310 Transmitter.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 19 May 2014 Resolved
Attach proper terminal lugs to the conductor ends and make proper connections to the terminal board in the ground-detection meter enclosure. 46CFR 183.05-50
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 7 July 2014
Resolution: Verified new connections as required. All sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2014 Resolved
Repair ground-fault in pilot house lighting circuit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 7 July 2014
Resolution: Verified no ground fault in pilot house circuit. Light removed and wires removed.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 19 May 2014 Resolved
Repair battery terminal connection on battery bank located behind generator. Connection is under high strain and half of the copper conductor strands are broken.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 7 July 2014
Resolution: Battery re-wired with new connections. All sat.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 19 May 2014 Resolved
Replace charred shore power receptacle on vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 7 July 2014
Resolution: New shore power receptacle and cable on dock. All sat.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 19 May 2014 Resolved
Repair high level bilge alarm for #4 VOID
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2014
Resolved 7 July 2014
Resolution: Tested new high level bilge alarm. Light and alarm function properly.
Lifesaving › Work Vest › Approval
Issued 30 May 2012 Resolved
Replace work vests for crew w/ type approved for use as work vests IAW 46CFR160.053 or 160.077 as req by 46CFR180.72(c) & (d).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 July 2012
Resolved 12 July 2012
Resolution: Company provided proof of purchase for new life jackets approved for use as Work vests on commercial vessels under 46CFR160.053
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 May 2012 Resolved
Vsl hull is carrying current when vsl is connected to shore power. Provide isolation xfmr or other acceptable means to prevent ship's hull from carrying current while on shore power. 46CFR 183.370
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2013
Resolved 6 June 2013
Resolution: Verfied installation of isolation xfmr on 25MAR13. Verfied installation of required ground detection on 06JUN13. All sat.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 30 May 2012 Resolved
Replace circuit breaker for shore tie in engine room. Shore tie cable is 10 AWG & is spliced to 6 AWG in the E/R distribution panel & is protected by a 100 amp circuit breaker. Circuit breaker should be sized to provide protection for the 10 AWG cable at approx 30 amperes.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 18 June 2012
Resolution: Vessel replaced circuit breaker in E/R for shore tie cable with a 30 amp breaker as required to protect the 10AWG conductor. All sat.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 30 May 2012 Resolved
Provide proper sized over-current protection for conductors supplying power to the LED ammeter installed at the engine room switchboard. Wire is 10 or 12 AWG and is currently protected by a 90 AMP circuit breaker which is far too large. Over-current protection needs to be sized to protect the conductor at either 20 or 30 amperes depending on the wire size.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 18 June 2012
Resolution: Vsl installed 20 amp circuit breaker to suuply power for LED ammeter. All sat.
Electrical › Electric Generation Source (service) › Generator
Issued 30 May 2012 Resolved
Deficiency is for the engine alternators. Alternator windings are full of oil and must be cleaned. 46CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2012
Resolved 12 July 2012
Resolution: Company opted to replace the alternators on each main engine. All sat.
Electrical › Electric Supply System (service) › Cable
Issued 30 May 2012 Resolved
Vsl approved one line diagram does not match what is on the vsl. Resubmit 120V one line diagram. Drawing must indicate circuit breakers for shore-tie, generator power & the main circuit breaker for the E/R distribution panel. Also, drawing must indicate where the shore tie conductors are spliced & change from 10AWG to 6 AWG conductor. 46CFR 177.202(4) & Part 183
Action required: 705 - Other - as specified
Due 25 April 2013
Resolved 25 March 2013
Resolution: Received updated vessel AC one line diagram. Made some minor pen and ink corrections. All sat.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 15 July 2011 Resolved
Generator lost power due to fuel pump failure.
Action required: 705 - Other - as specified
Due 17 July 2011
Resolved 15 July 2011
Resolution: Fuel pump replaced by tech. Tested sat.
Electrical › Electric Generation Source (service) › Panelboard
Issued 19 July 2008 Resolved
Install and demonstrate proper operation of service generator Ammeter iaw 46 CFR 183.10-5 (old T).
Action required: 705 - Other - as specified
Due 19 August 2008
Resolved 10 April 2009
Resolution: Ammeter installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 June 2008 Resolved
Ensure watertight tankroom bulkhead is watertight where wire passes through IAW 46 CFR 179.320
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 19 July 2008
Communications › Radio Communications › EPIRB
Issued 19 June 2008 Resolved
Ensure pull line for EPIRB activation is replaced because of wastage IAW 46 CFR 180.64.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 19 July 2008
Electrical › Electric Generation Source (service) › Generator Cable
Issued 19 June 2008 Resolved
Ensure wiring (12 guage) matches wiring (10 guage) on vessel's electrical plans IAW 46 CFR 177.202 (b)(4).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 19 July 2008
Stability › Unintentional Flooding › General
Issued 19 September 2007 Resolved
Prior to carrying passengers, demonstrate proper operation of engine room bilge high level alarm and float switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2007
Stability › Watertight Integrity › General
Issued 19 September 2007 Resolved
Prior to 19 Oct 07 provide catch chains or other securing devices on all hatch covers exposed to the weather (aft deck).
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 20 September 2007
Stability › Watertight Integrity › Deadlight Cover
Issued 19 September 2007 Resolved
Prior to 19 Oct 07 properly repair deadlight cover, womens head, by replacing missing dog.
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 20 September 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 June 2006 Resolved
Provide proper insulation of MDE's IAW 46 CFR 182.430
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 14 July 2006
Lifesaving › Lifebuoys › Size
Issued 8 June 2006 Resolved
Replace dry routed life rings (2 total) with approved type. IAW 46 CFR 180.70
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 14 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 June 2006 Resolved
Provide approved electrical one-line drawing IAW 46 CFR 176.700
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 19 June 2008
Resolution: Deficiency cleared to the satisfaction of an attending Coast Guard Marine Inspector.
Fire Fighting › Fire Pumps
Issued 2 May 2002 Resolved
NO REMOTE OPERATION FOR FIRE PUMP AT OPERATING STATION LEGACY COMPONENT DESC: Power Source
Condition: Improper Installation
Due 16 May 2002
Resolved 14 May 2002
Lifesaving › Lifejacket/PFD (General)
Issued 2 May 2002 Resolved
NO LIFE JACKET DONNING PLACARDS LEGACY COMPONENT DESC: Marking
Condition: Improper Installation
Due 16 May 2002
Resolved 14 May 2002
Engineering › Bilge Water Management System
Issued 2 May 2002 Resolved
CENTER VOID HIGH LEVEL ALARM NEEDS TO BE MOVE UP BECAUSE FALSE INDICATIONS INDUCE OPERATOR TO SECURE WARNING INDICATOR. LEGACY COMPONENT DESC: Eductor
Condition: Improper Installation
Due 16 May 2002
Resolved 14 May 2002
Navigation › Collision/Grounding Avoidance
Issued 2 May 2002 Resolved
ANCHOR LIGHT BULB MISSING LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2002
Resolved 14 May 2002
Documentation
Issued 11 May 2001 Resolved
Prove procurement of current copy of 46 CFR Subchapter "T"
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Construction/Loadline
Issued 11 May 2001 Resolved
Make proper repairs to port fwd and stbd galley port lights
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Lifesaving
Issued 11 May 2001 Resolved
Post emergency instruction list
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Engineering
Issued 11 May 2001 Resolved
Install guard over belts and pulleys on generator
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Navigation
Issued 11 May 2001 Resolved
Vessel restricted to daylight operation only pending proof of proper operation of compass light.
Condition: Unknown
Due 29 May 2001
Resolved 29 May 2001
Lifesaving
Issued 11 May 2001 Resolved
Prove purchase of current Hamor-type hydrostatic release unit for EPIRB
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Construction/Loadline
Issued 4 September 1999 Resolved
Conduct temporary repairs to stbd shell plating in holding tank compartment. Provide documentation that temporary repairs have been completed prior to sailing with passengers.
Condition: Unknown
Due 4 September 1999
Resolved 4 September 1999
Construction/Loadline
Issued 4 September 1999 Resolved
Conduct permanent repairs to stbd shell plating in holding tank compartment. Damage is located approx between the 4th and 7th frame 40 inches above the turn of the bilge.
Condition: Unknown
Due 4 September 1999
Resolved 4 September 1999
Navigation
Issued 6 November 1998 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE REPLACE THE PORT SHAFT STERNTUBE CUTLASS BEARING TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 6 November 1998
Resolved 6 November 1998
Navigation
Issued 4 May 1998 Resolved
Vessel is required to stay within 01 mile of shore, Chicago Harbor to planetarium and within the Chicago Harbor/Monroe Harbor during periods of reduced visibility, until the magnetic compass is repaired and a new deviation table is completed.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Lifesaving
Issued 7 July 1997 Resolved
Renew life floats on vessel. Vessel's route is restricted to within one mile from shore untin requirement is cleared.
Condition: Unknown
Due 7 July 1997
Resolved 7 July 1997
Construction/Loadline
Issued 8 May 1996 Resolved
MAKE REPAIRS TO O2 PORTLITES FORWARD ON PORTSIDE OF VESSEL. ONE REQUIRES REINSTALLATION OF COVER, ONE REQUIRES REINSTALLATION OF SECURING DEVICE (DOG).
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Navigation
Issued 11 May 1995 Resolved
Provide current magnetic compass deviation card._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1995
Resolved 3 July 1995
Construction/Loadline
Issued 11 May 1995 Resolved
Replace gasket on Class I Watertight Door and properly adjust clousre mechanism._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1995
Resolved 3 July 1995
Engineering
Issued 11 May 1995 Resolved
Install required flame screens on all fuel tank vents.
Condition: Unknown
Due 13 June 1995
Resolved 3 July 1995
Engineering
Issued 11 May 1995 Resolved
Repalce in kind STBD 4 inch non-metalic wet exhaust hose/pipe.
Condition: Unknown
Due 13 June 1995
Resolved 3 July 1995
Electrical
Issued 11 May 1995 Resolved
Repair weathertight cover on electric outlet box in way of main deck amidship on stern.
Condition: Unknown
Due 13 June 1995
Resolved 3 July 1995
Construction/Loadline
Issued 11 May 1995 Resolved
Properly seal bulhead peetration leading to lazaret/steering compartment._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1995
Resolved 3 July 1995
Lifesaving
Issued 6 July 1993 Resolved
Provide sufficient life floats or buoyant apparatus for 50% of total persons allowed on COI. Vessel is limited to within 1 mile of shore until provided.
Condition: Unknown
Due 6 July 1993
Resolved 6 July 1993
Lifesaving
Issued 6 July 1993 Resolved
Mark all PFD's with vessels name. Provide two additional adult PFD's. Vessel is limited to a maximum of 73 total persons until additional PFD's are provided.
Condition: Unknown
Due 6 July 1993
Resolved 6 July 1993
Lifesaving
Issued 6 July 1993 Resolved
[name withheld] with name of vessel. Obliterate all previous vessel names on EPIRB.
Condition: Unknown
Due 6 July 1993
Resolved 6 July 1993
Electrical
Issued 6 July 1993 Resolved
Lable breakers on new distribution panel in engine room to starboard of watertight door.
Condition: Unknown
Due 6 July 1993
Resolved 6 July 1993
Fire Fighting
Issued 6 July 1993 Resolved
provide additional B-II portable fire extinguisher to replace B-I portable fire extinguisher in the engine room.
Condition: Unknown
Due 7 July 1993
Resolved 7 July 1993
Electrical
Issued 6 July 1993 Resolved
Provide acid resistant lining in main engine starting battery box, and block batteries in place to prevent movement.
Condition: Unknown
Due 6 July 1993
Resolved 6 July 1993
Lifesaving
Issued 18 May 1992 Resolved
PROVIDE PRIMARY LIFESAVING FOR 50% OF TOTAL PERSONS CARRIED. ROUTE IS RESTRICTED TO WITHIN 1 MILE OF SHORE UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 18 May 1992
Resolved 18 May 1992
Documentation
Issued 4 October 1991 Resolved
PROVIDE GREAT LAKES AGREEMENT RADIOTELEPHONE CERTIFICATE. TO BE COMPLETED PRIOR TO CARRIAGE OF PASSENGERS ON LAKE MICHIGAN.
Condition: Unknown
Due 4 October 1991
Resolved 4 October 1991
Lifesaving
Issued 4 October 1991 Resolved
PROVIDE CLASS "C" EPIRB. MUST BE COMPLETED PRIOR TO CARRIAGE OF PASSENGERS ON LAKE MICHIGAN.
Condition: Unknown
Due 4 October 1991
Resolved 4 October 1991
Engineering
Issued 4 June 1990 Resolved
PROVIDE WOODEN PLANK TO ISOLATE THE GENERATOR REMOTE SHUTOFF VALVE FROM THEFUEL TANK SPACE.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Lifesaving
Issued 4 June 1990 Resolved
PROVIDE REFLECTION TAPE FOR 3 ADULT LIFEJACKETS AND PROVIDE 3 ADDITIONAL JACKETS. VESSEL IS LIMITED TO THE CARRIAGE OF 65 TOTAL PERSONS UNTIL COMPELTED.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Construction/Loadline
Issued 4 June 1990 Resolved
CLEAR THE AFTER HATCH COAMING DRAIN HOLE.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Engineering
Issued 4 June 1990 Resolved
PROVIDE MEANS TO SECURE REACH ROD TO MAIN FUEL TANK VALVE HANDLES TO PREVENT REACH ROD FROM DISENGAGING FROM VALVE HANDLE.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Electrical
Issued 4 June 1990 Resolved
PROVIDE A HAND RELIEVING DEVICE FOR THE AIR COMPRESSOR RELIEF VALVE.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Deck/Cargo
Issued 4 June 1990 Resolved
PROVIDE SUFFICIENT DISCHARGE HOSE FOR THE HAND BILGE PUMP.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Electrical
Issued 4 June 1990 Resolved
REPAIR PREHEAT GLOW PLUGS FOR THE GENERATOR (ONLY 1 OF 3 IS WORKING).
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Construction/Loadline
Issued 2 May 1990 Resolved
CREDIT DRYDOCK DUE 02NOV91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
REPLACE 2 PLASTIC THRU HULS WITH METALLIC ONES WELDED ON BOTH SIDES.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Deck/Cargo
Issued 2 May 1990 Resolved
REPLACE O/B DRAIN HOSES WITH WIRE REINFORCED HOSE AND FIT A VALVE AT THE SIDESHELL.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990 Resolved
PROVIDE REMOTE OPERATION FOR THE GENERATOR FUEL SUPPLY SHUTOFF VALVE (OPERATED FROM OUTSIDE FUEL TANK SPACE).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
SEAL/MAKE WATERTIGHT THE STBD AFTER HATCH COAMING TO 12" HIGH.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
WELD/MAKE WATERTIGHT THE AFTER BULKHEAD OF THE MIDSHIP HOLD.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
RENEW THE GASKET IN THE COLLISION BULKHEAD HATCH TO MAKE IT WATERTIGHT.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Navigation
Issued 2 May 1990 Resolved
PROVE OPERATION OF STEERING WHEN REASSEMBLED.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 3 April 1990 Resolved
CREDIT DRYDOCK DUE NO LATER THAN 02 MAY 1990.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Documentation
Issued 20 February 1990 Resolved
VESSEL IS OVERDUE FOR DRYDOCK. DRYDOCK THE VESSEL AS SOON AS POSSIBLE BUT NOT LATER THAN 21MAR90.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Engineering
Issued 2 May 1989 Resolved
INSTALL HEAT SHIELD FOR GENERATOR FUEL FILTER.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Accommodation/Occupational Safety
Issued 2 May 1989 Resolved
PROVIDE NAMEPLATE FOR AC GENERATOR.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Navigation
Issued 2 May 1989 Resolved
REPLACE LIGHT IN LAZARETTE AND INSTALL GUARD AROUND LIGHT IN FUEL TANK SPACE.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Navigation
Issued 2 May 1989 Resolved
RENEW GASKETS ON ALL PORT LIGHTS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Documentation
Issued 22 February 1989 Resolved
PROVIDE ELECTRIC ONE LINE DIAGRAM.
Condition: Unknown
Due 22 February 1989
Resolved 22 February 1989
Accommodation/Occupational Safety
Issued 22 February 1989 Resolved
INSTALL FENCING AROUND RAILS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 February 1989
Resolved 22 February 1989
Lifesaving
Issued 22 February 1989 Resolved
PROVIDE L/F OR B/A FOR 50% OF TOTAL PERSONS CARRIED STENCILED WITH VESSEL NAME AND CAPACITY, ATTACHED VIA A 100' PAINTER AND APPROPRIATE FLOATFREE LINK, FLOATING ELECTRIC WATERLIGHT AND IF LIFEFLOATS ARE USED, THEN TWO 4' OARS MUST BE LASHED TO LIFEFLOAT AND STENCILED WITH VESSEL NAME PRIOR TO
Condition: Unknown
Due 22 February 1989
Resolved 22 February 1989
Lifesaving
Issued 4 August 1988 Resolved
PROVIDE REQUIRED NUMBER OF P.F.D.'S FOR TOTAL NUMBER OF PEROSNS ALLOWED BY CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Construction/Loadline
Issued 4 August 1988 Resolved
REPLACE EXISTING MACHINERY SPACE DOOR WITH A CLASS I (HINGED) WATERTIGHT DOOR WITH A QUICK ACTION CLOSING DEVICE OPERATIVE FROM BOTH SIDES OF THE DOOR DESIGNED TO WITHSTAND A HEAD OF WATER EQUIVALENT TO 10 FEET. ALSO, AN INDICATOR IN THE PILOTHOUSE MUST SHOW WHETHER THE DOOR IS OPEN OR CLOSED
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Navigation
Issued 4 August 1988 Resolved
STENCIL VESSEL NAME ON EPIRB AND CONDUCT OPERATIONAL TEST.
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Documentation
Issued 4 August 1988 Resolved
PROVIDE CERTIFICATE OF INSPECTION, FCC LICENSE, GREAT LAKES AGREEMENT AND PFD INSTRUCTIONS.
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Lifesaving
Issued 4 August 1988 Resolved
REPAIR OR REPLACE RING BUOY AND STENCIL VESSEL NAME ON SAME.
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Accommodation/Occupational Safety
Issued 4 August 1988 Resolved
COMPLETE INSTALLATION OF FENCING BETWEEN COURSES OF RAILINGS.
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Navigation
Issued 4 August 1988 Resolved
TEST RELIEF VALVE FOR AIR RECEIVER.
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Engineering
Issued 4 August 1988 Resolved
INSTALL GUARD AROUND PULLY FOR AIR COMPRESSOR ON STARBOARD ENGINE.
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Electrical
Issued 4 August 1988 Resolved
PLACE 8 VOLT BATTERIES IN LINED BATTERY BOX.
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Electrical
Issued 4 August 1988 Resolved
REMOVE OR PROPERLY WIRE DEAD ENDED WIRES UNDER GUAGE PANEL.
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Fire Fighting
Issued 4 August 1988 Resolved
TEST FIRE AND BILGE PUMPS
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Construction/Loadline
Issued 4 September 1987 Resolved
INSTALL STRAINERS ON ALL BILGE SUCTION LINES PRIOR TO OPS.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Construction/Loadline
Issued 4 September 1987 Resolved
PLUG/WELD MANY SMALL HOLES ON STERN IN WAY OF OLD NAME PLATE PRIOR TO OPS.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Construction/Loadline
Issued 4 September 1987 Resolved
COMPLETE ATTACHMENT OF BILGE FRAMES TO NEW INSERTS IN FWD HOLE.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987

Casualty record · 5

18 July 2008Routine · role: Involved in a Marine Casualty · activity 3474815
19 June 2009Routine · role: Involved in a Marine Casualty · at MICHIGAN AVENUE BRIDGE · activity 3645919
9 August 2009Routine · role: Involved in a Marine Casualty · activity 3564042
27 September 2009Routine · role: Involved in a Marine Casualty · activity 3663830
21 July 2013Routine · role: Involved in a Marine Casualty · activity 4989203
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.