Records from 2016 to 2026. Most recent: inspection, 12 May 2026.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 May 2026
Resolved
A vessel to which this subchapter applies must meet 46 CFR 181.405 (interconnected fire detection system) if it is operating on a Coastwise or Oceans route. The interconnected fire detection was not interconnected. Vessel is restricted to operating on a Limited Coastwise route until the system is interconnected to the satisfaction of the MI.
46 CFR 175.110 (c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 May 2026
Resolution: Vessel owner purchased new smoke detectors, connected them and sent a video of them working, which is provided in the documents tab.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 May 2026
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Cover for access to fuel shut off valves has large openings in it. Replace access cover to satisfaction of MI.
46 CFR 177.405 (e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2026
Resolution: New access cover for fuel shut off valve installed
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 May 2026
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. MI observes improper seal on both port and starboard ventilation closure devices to engine room. Adjust closure devices to the satisfaction of the MI.
46 CFR 182.465 (h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2026
Resolution: Vessel applied weather stripping and additional clamps to ventilation closure devices on both port and starboard side
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 12 May 2026
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency, operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include (1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; or (3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Vessel did not have overboard secured. Operator installed a chain and lock on the overboard valve.
33 CFR 159.7 (c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI witnessed the port shaft unbalanced while underway and the drip-less shaft seal leaking.
46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2025
Resolution: Yanks Marine pulled shaft and sent out to be straightened before reinstalling. Also, replaced dripless shaft seal and intermediate and strut cutlass bearings.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 April 2025
Resolved
In addition to meeting § 180.130, each life float and buoyant apparatus must be stowed as required under this section. MI witnessed forward life float secured by bungee cord, oars not lashed to aft life float, and tangled painter that connected the two life floats.
46 CFR 180.137
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 1 May 2025
Resolution: Forward life float bungee cord removed, oars lashed to aft life float, and untangled painter that connected the two life floats.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 29 April 2025
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable and made watertight. MI found two pipes in forward void compartment on the starboard side leading to engine room compartment not watertight.
46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 1 May 2025
Resolution: sealed two pipes in forward void compartment on the starboard side leading to engine room compartment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed. MI found broken hose clamp on crankcase breather flexible hose.
46 CFR 182.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 1 May 2025
Resolution: replaced broken hose clamp on crankcase breather flexible hose
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 April 2025
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. MI found engine room compartment and forward void compartment missing securing devices.
46 CRF 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 1 May 2025
Resolution: installed engine room compartment and forward void compartment hatch securing devices
08 - Alarms › N/A - No Subsystem › General alarm
Issued 29 April 2025
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length, a battery powered bullhorn may serve as the public address system if audible throughout the accommodation spaces of the vessel during normal operating conditions. The bullhorn's batteries are to be continually maintained at a fully charged level by use of a battery charger or other means acceptable to the cognizant [name withheld] found vessels public address system non-operational. Repair current public address system or supply a battery powered bullhorn.
46 CFR 183.550
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 1 May 2025
Resolution: repaired vessels public address system be operational
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 April 2025
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. MI found missing cover on starboard anchor line cover.
46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 15 May 2025
Resolution: Operator installed new starboard anchor line cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2025
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. MI found deteriorated flexible hose connected to the port bilge overboard connection.
46 CFR 182.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 1 May 2025
Resolution: replaced deteriorated flexible hose connected to the port bilge overboard connection
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found deteriorated electrical box cover and missing cord connectors under operating station.
46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 1 May 2025
Resolution: installed new electrical box and cord connectors under operating station
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 August 2023
Resolved
Master of vessel needs to have preemployment drug testing and be enrolled in the vessels drug alcohol programs. Provide required documentations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2023
Resolution: Provided required documention.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 August 2023
Resolved
Vessels is required to have a logbook onboard at all times. Provide logbook and documented required drills. New crew members need to complete drills prior to getting underway.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 16 August 2023
Resolution: Logbook onboard vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2023
Resolved
Vessel is missing #3 2.5 gallon fire buckets with lanyard and marked "FIRE BUCKET". Provide required buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 10 August 2023
Resolution: Fire buckets are onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 August 2023
Resolved
Masthead light is not operable. Light is required to be working onboard vessel. Limit voyages to day light until light is working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 10 August 2023
Resolution: Repaired mast light.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 August 2023
Resolved
Aspirin is expired onboard vessels. Provide aspirin that is not expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 16 August 2023
Resolution: Aspirin onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 August 2023
Resolved
Life float lines are deteriorated on some. Replace lines on both Life floats with same type and length of previous.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 16 August 2023
Resolution: Lifelines have been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2023
Resolved
Engine room has two dead end wires. Remove wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 10 August 2023
Resolution: Wires have been corrected.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 8 August 2023
Resolved
Sewage valve for the MSD is not locked. Install a lock and chain to prevent accidental discharge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 10 August 2023
Resolution: Sewage valve is zip tided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 August 2023
Resolved
FCC Station license not onboard the vessel. Provide required documentation and keep onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 10 August 2023
Resolution: FCC safety license is current and correct vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2022
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories.
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The fuel line from the fuel tank to the generator does not have a shutoff valve at the tank.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2023
Resolved 18 May 2023
Resolution: Fuel shutoff valve has been installed and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 October 2021
Resolved
Vessels on LC voyages are req'd 12 flares (6 hand red & 6 orange smoke, or 12 hand red); vessel has 8 flares on board. Provide enough flares to equal 12 approved type for voyage. Vessel restricted to LBS route.
Action required: 10 - Deficiency Rectified
Resolved 15 October 2021
Resolution: provided
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 October 2021
Resolved
Vessel req'd Cat1 EPIRB. Battery on EPIRB was expired (09/2021). Provide new batter for EPIRB, or purchase new EPIRB and register. Vessel restiricted to w/in 3m from shore (not to operate on the high seas).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 March 2022
Resolution: Rec'd info and updated in MISLE
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 October 2021
Resolved
Fuel shut off valves are req'd to be labeled. Labeling on fule shut off valves has faded/non-existant. Label fuel shut off valves.
Action required: 10 - Deficiency Rectified
Resolved 15 October 2021
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2021
Resolved
Properly label PFD stowage for adults and children. Numbers on plaques did not match quantity of PFD's in container. Provide the PFD's to match qty, or re-label.
Action required: 10 - Deficiency Rectified
Resolved 15 October 2021
Resolution: completed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 October 2021
Resolved
Provide copy of FCC station License w/new vessel name. Old station license cancelled, provide new info and post on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2021
Resolution: Rec'd
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2019
Resolved
A visual and audible alarm must be provided at the operating station. Engine room light for bilge alarm was inoperable.
46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2019
Resolved 17 May 2019
Resolution: audible and visual alarm was observed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2019
Resolved
A visual and audible alarm must be provided at the operating station. Audible and visual alarms for bunk room is inoperable.
46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2019
Resolved 17 May 2019
Resolution: audible and visual alarm was observed
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 May 2019
Resolved
Each survial craft on the vessel must be in good working order and ready for immediate use. Vessel's forward life float is water logged and needs replaced.
46 CFR 185.700
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2019
Resolved 17 May 2019
Resolution: survival craft was placed in service
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 May 2019
Resolved
Each life float must be fitted with 2 paddles of at least 4ft and lashed to the life float. Both life float paddles need replaced.
46 CFR 180.175(f)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 17 May 2019
Resolution: new paddles was placed on survival craft
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 15 May 2019
Resolved
Master did not have Marine Operator Permit. Vessel is restricted to 1000 ft from shore.
47 CFR 80.159
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 17 May 2019
Resolution: Recieved photo of Marine Operators Permit
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 May 2019
Resolved
Vessel life floats must be stowed as far as practicable in a position and protected from fire. Vessel's aft life float was sitting on electrical wiring.
46 CFR 180.130(10)
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 13 June 2019
Resolution: recieved photo of moved life float
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019
Resolved
An exterior lighting fixture operating more than 50 volts must comply with UL 595. Provide UL specs for newly installed deck lights.
46 CFR 183.410(d)
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 27 June 2019
Resolution: Recieved photo of correct electrical repairs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 May 2019
Resolved
Vessel's stern light was inoperable.
46 CFR 183.420
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 17 June 2019
Resolution: CG MI verified operation of the stern light.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019
Resolved
Electrical equipment in spaces containing machinery spaces must be explosion proof. Lights in engine room were missing guards.
46 CFR 183.530
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 12 June 2019
Resolution: Recieved photo of lihgts with guards
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019
Resolved
The wires on the foward lights on upper mast, the connection need to made within an enclosure.
46 CFR 183.340(g)
17JUN2019 - due date extended to 21JUN2019.
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 27 June 2019
Resolution: recieved photos of electrical enclosures.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 May 2019
Resolved
Verify hydrostatic realease unit for EPIRB servicing date.
46 CFR 185.740
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 29 May 2019
Resolution: Received cert of EPIRB servicing
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019
Resolved
Wires for stern light connection must be made in an enclosure.
46 CFR 183.340(g)
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 27 June 2019
Resolution: Recieved photos of enclosures
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 May 2019
Resolved
Each survival craft must be visually inspected to ensure readiness for use. Vessel's aft life float needs patch work due to penetrations.
46 CFR 185.702
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 13 June 2019
Resolution: Recieved photos of repaired life float
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 May 2019
Resolved
Number of penetrations in a watertight bulkhead must be minimized and made watertight. Piping running through bulkhead from engine room to aft void were not watertight.
46 CFR 179.320
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 13 June 2019
Resolution: Recieved photo of sealed through hole fitting
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019
Resolved
Vessel must carry first aid kit that is approved under 46 CFR 160.41. Vessel had incorrect first aid kit.
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 12 June 2019
Resolution: Recieved photo of new first aid kit
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2019
Resolved
The fire extinguisher bracket located on maindeck foward needs to be replaced and relocated due to deteriation and bracket does not fully open due to location.
46 CFR 185.500(d)
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 29 May 2019
Resolution: Recieved photo of new bracket
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2019
Resolved
Each portable extinguisher needs to be of the approved type. Pilot house needs 10 B:C extinguisher
46 CFR 185.500
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 12 June 2019
Resolution: Photo of new extinguisher
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2019
Resolved
Clean terminal blocks on batteries in engine room.
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 17 May 2019
Resolution: Recieved phots of clean terminals
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 May 2019
Resolved
Clean edges and tighten hatch scuttles to maintain watertight integrity on Engine Room and Lazarette scuttles.
46 CFR 179.360
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 12 June 2019
Resolution: Recieved photo of clean knife edges on hatches
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 May 2019
Resolved
Replace gasket on forepeak scuttle.
46 CFR 179.360
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 13 June 2019
Resolution: Recieved photo of new gasket install
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019
Resolved
Wire connections for lights in pilot house must be in an enclosure.
46 CFR 183.340(g)
17JUN2019 - due date extended to 21JUN2019.
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 27 June 2019
Resolution: Recieved photos of proper enclosures
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 15 May 2019
Resolved
Vessel's radar must be installed and be suitable for the intended speed and route of vessel. Vessel's radar was inoperable.
46 CFR 184.404
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 13 June 2019
Resolution: Recieved photo of operating radar
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2019
Resolved
An exposed hazard, such as gears or rotating machinery must be properly protected by a cover, guard, or rail. Veesel missing guards on rotating belts on engine.
46 CFR 177.960
17JUN2019 - due date extended to 21JUN2019.
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 2 July 2019
Resolution: Attended vessel, witnessed guards installed
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 May 2019
Resolved
Monthly inspections required ny NFPA 10 needs to be conducted. No monthly tests on portable extinguisher were completed.
46 CFR 176.810(b)(1)(ii)
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 12 June 2019
Resolution: Photo of monthly inspection tags on extinguishers
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019
Resolved
Stardboard side lights on main deck need sockets.
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 29 May 2019
Resolution: Photo of socket installed in light fixture
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 15 May 2019
Resolved
Conduct satisfactory fire and abandon ship drill in the presence of a marine inspector.
46 CFR 185.520
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2019
Resolved 17 May 2019
Resolution: witnessed satisfactory fire and abandon ship drill
Lifesaving › Lifefloat › Serviceable
Issued 24 April 2018
Resolved
Life float must meet series 160.027 requirements. Life float needs to be serviced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 30 April 2018
Resolution: Confirmed lifefloat was properly serviced.
Lifesaving › Lifefloat › Serviceable
Issued 24 April 2017
Resolved
17 man lifefloat needs to be serviced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 1 June 2017
Resolution: 17 man lifefloat was serviced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 April 2016
Resolved
Provide high level bilge alarms (audible and visual) for storage space. Label alarms properly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: Tested all bilge alarms.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Service
Issued 7 April 2016
Resolved
Provide servicing report for fixed fire system.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: Service provided for all FF
Stability › Watertight Integrity › General
Issued 7 April 2016
Resolved
Remove water in steering compartment and perform sea trials under way.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: All water removed, and bilge pump tested.
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 April 2016
Resolved
Provide operable fuel shuutoff valves (03).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: All valves replaced.
Engineering › Bilge Water Management System › Strainer
Issued 7 April 2016
Resolved
Provide strainers for all fixed bilge systems.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: All bilges installed with strainers.
Engineering › Bilge Water Management System › Valve
Issued 7 April 2016
Resolved
Provide valves for allelectric bilge o/b pipes.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 20 April 2016
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 7 April 2016
Resolved
Replace port fuel tank vent tube.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 17 June 2016
Resolution: Replaced vent pipe.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 7 April 2016
Resolved
Install means to secure MSD overboard valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 7 April 2016
Resolved
Removed unused hose on macerator pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 20 April 2016
Engineering › Fuel Oil Service System › Filter
Issued 7 April 2016
Resolved
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 April 2016
Resolved
Repair STB MDE wet exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2016
Resolved 17 June 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 7 April 2016
Resolved
Inspect lighten auxiliary belts on MDEs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 20 April 2016
Engineering › Fuel Oil Service System › Tank
Issued 7 April 2016
Resolved
Make tank compartment available for inspection. Remove excessive oil and water in bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 April 2016
Engineering › Fuel Oil Service System › Ventilation
Issued 7 April 2016
Resolved
Provide engine vent closures.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Construction/Loadline › Penetrations › Bottom Plug
Issued 7 April 2016
Resolved
At next DD/ISE, inspect fixed port stuffing box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 March 2017
Resolution: Fixed port stuffing box inspected at credit DD/ISE; all sat.
Engineering › Bilge Water Management System › Pump
Issued 7 April 2016
Resolved
Provide proper operation of fixed bilge pump in tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 April 2016
Resolved
Post valid COI, Stability letter and addendum.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 20 April 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 7 April 2016
Resolved
Program MMSI number into VHF radio.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 17 June 2016
Documentation › Certificates/Documents › FCC SSL
Issued 7 April 2016
Resolved
Provide proof of valid FCC SSL.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 April 2016
Communications › Radio Communications › EPIRB
Issued 7 April 2016
Resolved
Provide proof of valid EPIRB battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 April 2016
Lifesaving › Lifefloat › Markings
Issued 7 April 2016
Resolved
Mark life floats with passenger count.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 20 April 2016
Lifesaving › Lifefloat › Retroreflective Material
Issued 7 April 2016
Resolved
Replace retro tape on lifefloats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 20 April 2016
Fire Fighting › Fire Bucket › Availability
Issued 7 April 2016
Resolved
Provide fire buckets (03).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Lifesaving › Hand Flares › Storage
Issued 7 April 2016
Resolved
Provide watertight flare box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 April 2016
Engineering › Bilge Water Management System › Pump
Issued 7 April 2016
Resolved
Mount electric bilge pump in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 20 April 2016
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 7 April 2016
Resolved
Provide two (02) portable lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 20 April 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 April 2016
Resolved
Provide updated coast pilot and light list.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 April 2016