MAURY USCG vessel records
← All vessels

BEGONIA

BEGONIA is a 2003 tank ship. The Coast Guard has recorded 9 inspections since 2019, most recently in January 2025, along with 5 deficiencies and 1 operational control.

Records from 2019 to 2025. Most recent: inspection, 15 January 2025.

Built
2003
Last inspected
15 January 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 January 2025
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2019–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9287297
738049
Flag
TUVALU
Maury page id
psix-738049

Documentation record

Tonnage as PSIX records it11627 - Convention (Subpart B), Gross Ton
20621 - Dead Weight, Metric Ton
25979 - Displacement, Metric Ton
6418 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

15 January 2025 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8063702
4 November 2024 COC-CHEM Renew
Type not classified · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8029149
7 July 2023 PSC B · COC-CHEM Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7734728
16 September 2022 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7560186
18 March 2022 COC-CHEM & TVE Renew · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7414169
3 March 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7149684
3 November 2020 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7089230
5 November 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6849349
3 November 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6844450

Deficiency record · 5

11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 4 November 2024 Resolved
The normal equipment for every lifeboat shall consist of a food ration totaling not less than 10,000KJ for every person the lifeboat is permitted to accommodate. Rations shall be kept in airtight packaging and be stowed in a watertight container. PSCO observed 17 damaged food rations, 8 in the port lifeboat and 9 in the starboard rescue boat. 74 SOLAS (20) III/34 – LSA 4.4.8.12
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2024
Resolved 8 November 2024
Resolution: Vessel purchased and replaced defective rations.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 November 2020 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. The Annex I sample locker (lockers I and II) have a water spray fire protection system. The nozzles of the spray rail were occluded or blocked by rust and debris in at least 6 of the 8 visible nozzles. The blockages would severly degrade the effectiveness of the system. 74 SOLAS (04) II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2020
Resolved 17 November 2020
Resolution: Recieved class report from NKK attesting to surveyor witnessing satisfactory repairs of system. system reported in good working condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2019 Resolved
74 SOLAS (14) I/11a The condition of the ship and its equipment shall be maintained to conform with the provisions of current regulations to ensure the ship will remain fit to proceed to sea without danger to the ship. PSCO observed a pin-hole saltwater leak in the inlet side of saltwater piping for the lube oil cooler. Temporary repairs shall be completed prior to departure to the satisfaction of the RO. Permanent repair shall be completed within 30 days to the satisfaction of the RO.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2019
Resolution: Class report received.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 November 2019 Resolved
46 CFR 39.2001 (h) The last 1 meter of vapor piping upstream of the connection must painted in the sequence Red/Yellow/Red. PSCO observed VCS connection piping piping painted only red and yellow with VAPOR verbiage faded.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2019
Resolution: Class report received.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 November 2019 Resolved
46 CFR 39.2001(j) Each vessel vapor connection flange face must have a permanent stud projecting outward that is at least 1 inch long. PSCO observed one VCS stud missing and 03 VCS studs of non-permanent nature.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2019
Resolution: Class report received.