← All vessels
BEGONIA
BEGONIA is a 2003 tank ship. The Coast Guard has recorded 22 inspections since 2005, most recently in January 2025, along with 18 deficiencies and 4 operational controls.
Records from 2005 to 2025. Most recent: inspection, 15 January 2025.
- Built
- 2003
- Last inspected
- 15 January 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9287297 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
T2WL5
738049
Flag
TUVALU
—
Maury page id
psix-738049
Inspections, by type
…with no type recorded4
Years with a record
13 calendar years (2005–2025)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it11627 - Convention (Subpart B), Gross Ton
20621 - Dead Weight, Metric Ton
25979 - Displacement, Metric Ton
6418 - Convention (Subpart B), Net Ton
20621 - Dead Weight, Metric Ton
25979 - Displacement, Metric Ton
6418 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
15 January 2025
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8063702
4 November 2024
COC-CHEM Renew
Type not classified · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8029149
7 July 2023
PSC B · COC-CHEM Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7734728
16 September 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7560186
18 March 2022
COC-CHEM & TVE Renew · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7414169
3 March 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7149684
3 November 2020
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7089230
5 November 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6849349
3 November 2019
Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6844450
17 June 2014
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4888982
25 June 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4356358
18 June 2012
COC-CHEM Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4347908
18 September 2008
COC-CHEM Annual · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3327213
25 January 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3136414
24 January 2008
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3136030
15 June 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2962865
10 June 2007
ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex II Examination · MARPOL Annex I Examination · COC-CHEM Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2954277
2 July 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2697768
2 July 2006
ISPS II Exam · Ballast Water Examination · COC-CHEM Annual
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2697984
12 March 2005
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2308701
1 March 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2301522
22 February 2005
COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2297107
Deficiency record · 18
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 4 November 2024
Resolved
The normal equipment for every lifeboat shall consist of a food ration totaling not less than 10,000KJ for every person the lifeboat is permitted to accommodate. Rations shall be kept in airtight packaging and be stowed in a watertight container. PSCO observed 17 damaged food rations, 8 in the port lifeboat and 9 in the starboard rescue boat. 74 SOLAS (20) III/34 – LSA 4.4.8.12
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 November 2020
Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: fire protection systems and fire-fighting systems and appliances shall be maintained ready for use.
The Annex I sample locker (lockers I and II) have a water spray fire protection system. The nozzles of the spray rail were occluded or blocked by rust and debris in at least 6 of the 8 visible nozzles. The blockages would severly degrade the effectiveness of the system.
74 SOLAS (04) II-2/14.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2019
Resolved
74 SOLAS (14) I/11a
The condition of the ship and its equipment shall be maintained to conform with the provisions of current regulations to ensure the ship will remain fit to proceed to sea without danger to the ship. PSCO observed a pin-hole saltwater leak in the inlet side of saltwater piping for the lube oil cooler. Temporary repairs shall be completed prior to departure to the satisfaction of the RO. Permanent repair shall be completed within 30 days to the satisfaction of the RO.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 November 2019
Resolved
46 CFR 39.2001 (h)
The last 1 meter of vapor piping upstream of the connection must painted in the sequence Red/Yellow/Red. PSCO observed VCS connection piping piping painted only red and yellow with VAPOR verbiage faded.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 November 2019
Resolved
46 CFR 39.2001(j)
Each vessel vapor connection flange face must have a permanent stud projecting outward that is at least 1 inch long. PSCO observed one VCS stud missing and 03 VCS studs of non-permanent nature.
Lifesaving › Lifeboat › Hull
Issued 18 June 2012
Resolved
The ship shall be so arranged that lifeboats, in their stowed positions, are protected from damage by heavy seas. Vessel's starboard side lifeboat has indent on port side aft, from wooden chucks. Request class report specifically attesting to repairs/alterations to starboard lifeboat. Survey was completed on September 9, 2011, and dropped in water on 21MAY2012.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 18 September 2008
Resolved
0100 (Docs/ Certificates) Vessel was missing cargo transfer procedures. 10 C
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 September 2008
Resolved
0999 (Other Safety in General) Portable oxygen, CO2, and LEL were not calibrated. They are required to be calibrated annually. 70 A/B
Deck/Cargo › Mooring/Anchoring › Winch
Issued 18 September 2008
Resolved
1330 (Winches and Capstans) STBD mooring winch/anchor windless leaking oil on to forecastle. 70 A/B
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 18 September 2008
Resolved
0900 (Safety in General) [name withheld] stretcher in the BALLAST PUMP ROOM has straps missing clips used to secure injured persons. 15 C
Fire Fighting › Ventilation Systems › Ducts
Issued 18 September 2008
Resolved
0745 (Fire Dampers) Fire damper in the 2nd level from the bottom, in the pump room, has a broken hinge. This will allow C02 to escape the space and creates a fire hazard. 70 A/B
Engineering › Steering Gear System › Rudder Stock
Issued 18 September 2008
Resolved
0936 (Steering Gear) Rudder post seal is leaking allowing water into the steering flats. Ship did not notify the company of this condition. 70 A/B
Operations/Management › Pollution › Control of Garbage
Issued 18 September 2008
Resolved
2120 (Garbage) Mixed garbage found throughout the ship. Fluorescent tubes and bunker samples found in glass containers. Plastic mixed with food. Ship's Garbage Management Plan lacks guidance on collection and disposal of hazardous waste, and garbage segregation throughout the ship. 70 A/B/C
Fire Fighting › Fire Hoses › Condition
Issued 18 September 2008
Resolved
0720 (Fire Fighting Equipment) Two hoses were found leaking. Integrity of all hoses questionable. Replace to satisfaction of class as necessary. 70 A/B
Fire Fighting › Fire Hoses › Condition
Issued 18 September 2008
Resolved
0720 (Fire Fighting Equipment) Two hoses were found leaking. Integrity of all hoses questionable. Replace to satisfaction of class as necessary. 70 A/B
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 September 2008
Resolved
0950 (Electric Equipment in General) Forward most junction box on cargo deck has a crack separating parts of the junction box. 70 A/B
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 18 September 2008
Resolved
1760 (Standard Discharge Connection) Containment around standard discharge connection on vessel's starboard side is insufficient. The connection extends beyond the containment. 70 A/B
Engineering › Thrusters › Pump
Issued 18 September 2008
Resolved
1499 (Other Prop and Aux. Machinery) Bow thrusters reported to be inoperable. Company was not notified of this condition.
70 A/B
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National