HONGKONG ENERGY is a 2004 tank ship. The Coast Guard has recorded 3 inspections since 2022, most recently in September 2023, along with 2 deficiencies.
Records from 2022 to 2023. Most recent: inspection, 16 September 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it73659 - Dead Weight, Ton 105000 - Displacement, Ton 28849 - Convention (Subpart B), Net Ton 96165 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
16 September 2023COC-GAS Renew · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7792221
5 April 2022Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7424863
24 February 2022PSC A · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7400472
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 February 2022Resolved
THE WATER SPRAY SYSTEM SHOULD COVER ALL AREAS MENTIONED IN 11.3.1 WITH A UNIFORMLY DISTRIBUTED WATER SPRAY. PSCOS OBSERVED SEVERAL CLOGGED NOZZLES ALONG THE SPRAY RAILS OF THE SUPERSTRUCTURE.
CITE: 74SOLAS(20)VII/13.1 - IGC(93) 11.3.2
ACTION TAKEN: 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 April 2022
Resolution: Received BV Class report dated 25MAR22 attesting to proper nozzle cleaning and satisfactory operational test of deck water spray.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2022Resolved
LIGHTING FITTINGS SHOULD HAVE PRESSUREIZED FITTINGS AND ENCLOSURES OR BE OF THE FLAME PROOF TYPE. PSCO OBSERVED ONE LIGHT FIXTURE IN THE COMPRESSOR ROOM WITH A CRACKED ENCLOSURE.
CITE: 74SOLAS(20) VII/13.1 - IGC(93) 10.2.4.1
ACTION TAKEN: 10C
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 24 February 2022
Resolved 24 February 2022
Resolution: CREW CONDUCTED LIGHTING FIXTURE CHANGE-OUT. DEFICIENCY RECTIFIED.