Records from 2016 to 2025. Most recent: inspection, 1 December 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Professional
Detail on this page
11 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 11
1 December 2025
Inclining Experiment · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8269755
29 October 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8012397
4 October 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7791767
6 October 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7574119
24 September 2021
DAPI Audit · Hull Examination · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7319804
1 October 2020
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7065286
24 September 2019
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6815259
27 September 2018
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6549480
28 September 2017
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6276856
13 September 2016
Drydock Exam · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5999087
5 August 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5980826
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 December 2025
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: Six hand red flare distress signals and six hand orange smoke distress signals. A hand red flare distress signal may be substituted for any of the required hand orange flare distress signals.
MI found the distress signals onboard to be expired.
46 CFR 180.68(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 December 2025
Resolved 7 December 2025
Resolution: Received evidence of newly purchased flares on board vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 December 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container or compartment for life jackets.
Vessel did not have markings for the stowage location or number of child lifejackets onboard.
46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2025
Resolved 15 January 2026
Resolution: Email was received with evidence of signage for child lifejacket stowage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2021
Resolved
AT LEAST ONE RING LIFE BUOY MUST BE FITTED WITH A LIFELINE. LIFELINE MUST BE AT LEAST 60 FEET.
MI NOTED LIFELINE WAS NOT 60 FEET IN LENGTH, LINE WAS AROUND 40 FEET LONG.
46 CFR 180.70(i)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2021
Resolved 19 October 2021
Resolution: Lifeline replacement is in compliance with 46 CFR 180.70(i)(2).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2021
Resolved
AN ADULT LIFE JACKET MUST BE PROVIDED FOR TEACH PERSON CARRIED ON BOARD THE VESSEL.
MI NOTED ONLY 3 ADULT LIFE JACKETS WERE IN SERVICEABLE CONDITION AND PROPERLY LABELED.
46 CFR 180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2021
Resolved 19 October 2021
Resolution: Found all 14 lifejackets in compliance with 46 CFR 180.71(a).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2021
Resolved
THE NUMBER AND IDENTIFICATION OF THE ITEMS STOWED INSIDE, AND THEIR SIZES, MUST BE MARKED IN CLEARLY LEGIBLE LETTERS AND NUMBERS ON EACH CONTAINER FOR LIFE JACKETS.
LIFE JACKET STOWAGE NOT LABELED WITH NUMBER OF LIFE JACKETS.
46 CFR 185.604(f)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2021
Resolved 19 October 2021
Resolution: Lifejackets stowage labeled in compliance with 46 CFR 185.604.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 September 2021
Resolved
PROPULSION MACHINERY MUST BE SUITABLE IN TYPE AND DESIGN FOR PROPULSION REQUIREMENTS OF THE HULL IN WHICH IT IS INSTALLED AND CAPABLE OF OPERATING AT CONSTANT MARINE LOAD UNDER SUCH REQUIREMENTS WITHOUT EXCEEDING ITS DESIGNED LIMITATIONS.
DURING MOB DRILL, ENGINE OVERHEATED.
46 CFR 182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2021
Resolved 19 October 2021
Resolution: MI witnessed for 45 minutes the proper operation of the engine, def cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 September 2021
Resolved
A VESSEL TO WHICH THIS SUBCHAPTER APPLIES MAY NOT BE OPERATED WITHOUT HAVING ON BOARD A VALID U.S. COAST GUARD CERTIFICATE OF INSPECTION.
VESSEL DOES NOT HAVE A VALID COI.
46 CFR 176.100(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2021
Resolved 30 September 2021
Resolution: Vessel obtained valid COI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 September 2018
Resolved
All fuel tanks must be electrically bonded to a common ground. MI observed ungrounded fuel tank. Ground. - 46CFR182.440(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2018
Resolved 19 October 2018
Resolution: Vessel owner bonded fuel tank to hull.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 September 2016
Resolved
Vessel's rails and courses are spaced at 12" intervals. Spacing of rails and courses on excursion vessels is required to be no greater than 4". Submit proposal for satisfying requirement to marine inspector IAW 46 CFR 177.900 (g) (1)
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 23 August 2017
Resolution: District approved height of air boat rails. Deficiency resolved.
Engineering › Fuel Oil Service System › Hose
Issued 13 September 2016
Resolved
Replace fuel supply hose from tank to shut off valve. Hose is dry rotted and unapproved type IAW 46 CFR 182.720
Due 27 September 2016
Resolved 30 September 2016
Construction/Loadline › Hull › Weld
Issued 13 September 2016
Resolved
Repair cracked welds where indicated by marine inspector IAW 46 CFR 176.610.
Due 13 September 2016
Resolved 13 September 2016
Documentation › Certificates/Documents › Stability Letter
Issued 13 September 2016
Resolved
Retain original stability letter or official copy on board IAW 46 CFR 176.306
Due 13 September 2016
Resolved 13 September 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 13 September 2016
Resolved
Vessel does not have the A-II fire extinguisher for the accommodation space as required by Table 181.500(a) of 46 CFR. Provide one A-II fire extinguisher for the accommodation space IAW 46 CFR 181.500
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 14 November 2016
Resolution: Approval letter from OCMI.