Records from 2016 to 2018. Most recent: operational control imposed, 24 July 2018.
Inspection history · 5
24 July 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6489553
23 July 2018
PII Safety Exam · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6475860
7 August 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6233330
11 April 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6118157
14 January 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5793968
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 July 2018
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization and in the manner having due regard to ensuring reliability of fire fighting systems and appliances. All fixed and portable fire fighting equipment has not been serviced since October 2016.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2018
Resolution: Received Class report and attended vessel to verify deficiency has been properly rectified.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 July 2018
Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. THe fire main system is leaking in way of a dresser coupling located on starboard side main deck outboard of No. 4 cargo hold
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2018
Resolution: Received Class report and attended vessel to verify that deficiency has been properly corrected.
Construction/Loadline › Structures › Deck Plating
Issued 11 April 2017
Resolved
0111-cargo ship safety construction 74 SOLAS (04)I/11(a): The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure remains fit to proceed to sea without danger to the ship or persons onboard. PSCO noted crack in corner plate of #1 cargo hold.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 7 August 2017
Resolution: SEC HOU-GAL PSC received a class report from ABS satisfyig the requirement.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 April 2017
Resolved
0899-accident prevention 74 SOLAS(04)II-1/45.5.6: Terminations and joins in all conductors shall be made as to retain the original electrical, mechanical, fire-resisting properties of the cable. Lighting fixtures are installed in the boatswain's store using electrical wire nuts outside of junction box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 7 August 2017
Resolution: SEC HOU-GAL PSC recoeved a class report from ABS satisfying the requirement.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 11 April 2017
Resolved
0715-fire detection74 SOLAS (04)II-2/14.1.1: Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Smoke detectors above service generators were seated with plastic.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2017
Resolved 11 April 2017
Resolution: Corrected on the spot. Plastic covering were removed and the detectors were tested and found operating properly.